Abstract
This paper investigates the use of fuzzy logic for fault detection and diagnosis in a pulsewidth modulation voltage source inverter (PWM-VSI) induction motor drive. The proposed fuzzy technique requires the measurement of the output inverter currents to detect intermittent loss of firing pulses in the inverter power switches. For diagnosis purposes, a localization domain made with seven patterns is built with the stator Concordia current vector. One is dedicated to the healthy domain and the six others to each inverter power switch. The fuzzy bases of the proposed technique are extracted from the current analysis of the fault modes in the PWM-VSI. Experimental results on a 1.5-kW induction motor drive are presented to demonstrate the effectiveness of the proposed fuzzy approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
What stator current processing-based technique to use for induction motor rotor faults diagnosis?
Benbouzid, M. E. H., & Kliman, G. B. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811741 · Cited by 485
Self-citationFault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Fault Diagnostic System for a Multilevel Inverter Using a Neural Network
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897128 · Cited by 291
Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines
Bachir, S., Tnani, S., Trigeassou, J.-C., & Champenois, G. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.874258 · Cited by 287
Cited by
Real-Time Motor Fault Detection by 1-D Convolutional Neural Networks
Ince, T., Kiranyaz, S., Eren, L., Askar, M., & Gabbouj, M. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2582729 · Cited by 1,407
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
“In [ 92 ], the same approach is used for a voltagefed pulse width modulation induction motor drive.”
MethodA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
An Overview of Artificial Intelligence Applications for Power Electronics
Zhao, S., Blaabjerg, F., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3024914 · Cited by 947
Gao, Z., Cecati, C., & Ding, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2419013 · Cited by 776
From Model, Signal to Knowledge: A Data-Driven Perspective of Fault Detection and Diagnosis
Dai, X., & Gao, Z. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2243743 · Cited by 728
A Data-Driven Fault Diagnosis Methodology in Three-Phase Inverters for PMSM Drive Systems
Cai, B., Zhao, Y., Liu, H., & Xie, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2608842 · Cited by 471
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“prove diagnostic results, since boundary lines between healthy and unhealthy conditions are often fuzzy [25].”
BackgroundEstima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“The use of the Park’s Vector Approach as a fault diagnostic tool for voltage source inverter faults was successfully applied in [10]-[13].”
MethodOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Artificial-intelligence-based approaches like neural network [16], fuzzy network [17], [12], and wavelet based methods [18]– [20] allow smart diagnosis with no need of a system model.”
BackgroundOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Model-Based Fault Detection and Identification for Switching Power Converters
Poon, J., Jain, P., Konstantakopoulos, I. C., Spanos, C., Panda, S. K., & Sanders, S. R. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2541342 · Cited by 257
Bearing fault detection by one-dimensional convolutional neural networks
Eren, L. (2017) · Mathematical Problems in Engineering · doi:10.1155/2017/8617315 · Cited by 250
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241
“a relatively long diagnosis time, because this method used the dimension of current patterns when the fault occurrence is determined [18], [19].”
BackgroundMethodA Survey on Active Fault-Tolerant Control Systems
Abbaspour, A., Mokhtari, S., Sargolzaei, A., & Yen, K. K. (2020) · Electronics · doi:10.3390/electronics9091513 · Cited by 218
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167
Diagnosis of Open-Switch and Current Sensor Faults in PMSM Drives Through Stator Current Analysis
Khojet El Khil, S., Jlassi, I., Marques Cardoso, A. J., Estima, J. O., & Mrabet-Bellaaj, N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2930592 · Cited by 147
“In [19], a fuzzy technique is employed to achieve open-circuit fault diagnosis in a three-phase inverter drive by building seven pattern-localization domains; one for the healthy mode, and the other six for the faulty mode.”
MethodWu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“However, open circuit does not immediately cause the system shutdown and can remain undetected for an extended period of time [10], this can lead to overstress on the healthy switches and in turn cause second failures in other components, as well as lead to a ripple outputs.”
Background
Metadata
- Authors
- Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008
- Volume
- 55
- Issue
- 2
- Pages
- 586-593
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2130326526
- Cited by
- 335
- References
- 25
- FWCI
- 45.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.