The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Open accessAbstract
Low-voltage ride-through (LVRT) requirements demand wind-power plants to remain connected to the network in presence of grid-voltage dips. Most dips present positive-, negative-, and zero-sequence components. Hence, regulators based on symmetrical components are well suited to control grid-connected converters. A neutral-point-clamped topology has been considered as an active front end of a distributed power-generation system, following the trend of increasing power and voltage levels in wind-power systems. Three different current controllers based on symmetrical components and linear quadratic regulator have been considered. The performance of each controller is evaluated on LVRT requirement fulfillment, grid-current balancing, maximum grid-current value control, and oscillating power flow. Simulation and experimental results show that all three controllers meet LVRT requirements, although different system performance is found for each control approach. Therefore, controller selection depends on the system constraints and the type of preferred performance features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Understanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
Understanding Power Quality Problems
Bollen, M. H. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546840 · Cited by 1,386
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
PWM regenerative rectifiers: state of the art
Rodriguez, J. R., Dixon, J. W., Espinoza, J. R., Pontt, J., & Lezana, P. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.841149 · Cited by 895
Self-citationFlexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347
Cited by
Recent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Self-citationA Survey on Cascaded Multilevel Inverters
Malinowski, M., Gopakumar, K., Rodriguez, J., & Pérez, M. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030767 · Cited by 2,322
Self-citationRodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Self-citationControl for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation
Balaguer, I. J., Lei, Q., Yang, S., Supatti, U., & Peng, F. Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049709 · Cited by 622
Guo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Single-Phase Seven-Level Grid-Connected Inverter for Photovoltaic System
Rahim, N. A., Chaniago, K., & Selvaraj, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064278 · Cited by 438
Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185016 · Cited by 339
Camacho, A., Castilla, M., Miret, J., Borrell, A., & de Vicuna, L. G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2347266 · Cited by 300
Son, J.-Y., & Ma, K. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2695485 · Cited by 295
Afshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733481 · Cited by 259
Power Quality Control of Smart Hybrid AC/DC Microgrids: An Overview
Nejabatkhah, F., Li, Y. W., & Tian, H. (2019) · IEEE Access · doi:10.1109/access.2019.2912376 · Cited by 258
Reviews on multilevel converter and modulation techniques
Hasan, N. S., Rosmin, N., Osman, D. A. A., & Musta’amal@Jamal, A. H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.163 · Cited by 178
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-06
- Volume
- 56
- Issue
- 6
- Pages
- 2162-2173
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2123828883
- Cited by
- 373
- References
- 14
- FWCI
- 16.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.