Survey on Fault Operation on Multilevel Inverters
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
This paper is related to faults that can appear in multilevel (ML) inverters, which have a high number of components. This is a subject of increasing importance in high-power inverters. First, methods to identify a fault are classified and briefly described for each topology. In addition, a number of strategies and hardware modifications that allow for operation in faulty conditions are also presented. As a result of the analyzed works, it can be concluded that ML inverters can significantly increase their availability and are able to operate even with some faulty components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Self-citationMultilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Self-citationThe age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016
Self-citationMulti-level conversion: high voltage choppers and voltage-source inverters
Meynard, T. A., & Foch, H. (2003) · PESC `92 Record. 23rd Annual IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1992.254717 · Cited by 1,455
Self-citationThe Active NPC Converter and Its Loss-Balancing Control
Bruckner, T., Bernet, S., & Guldner, H. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.847586 · Cited by 731
A Comparison of Diode-Clamped and Cascaded Multilevel Converters for a STATCOM With Energy Storage
Cheng, Y., Qian, C., Crow, M. L., Pekarek, S., & Atcitty, S. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882022 · Cited by 336
Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906994 · Cited by 284 · cited 1×
“2 ) Use of AI Algorithms: In [6], the use of artificial intelligence (AI) algorithms, due to their ability to recognize patterns, is proposed to detect and identify faults in a CM inverter.”
BackgroundOperation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Self-citationExtended Operation of Cascade Multicell Converters Under Fault Condition
Lezana, P., & Ortiz, G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2019771 · Cited by 219
Self-citationFault Detection on Multicell Converter Based on Output Voltage Frequency Analysis
Lezana, P., Aguilera, R., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013845 · Cited by 215
Self-citation
Cited by
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
A New Multilevel Converter Topology With Reduced Number of Power Electronic Components
Ebrahimi, J., Babaei, E., & Gharehpetian, G. B. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2151813 · Cited by 525
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 473
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
“On the other hand, the probability of switch failures over a specific time interval in multilevel inverters is higher than conventional inverters [36].”
BackgroundPowering the Future of Industry: High-Power Adjustable Speed Drive Topologies
Kouro, S., Rodriguez, J., Wu, B., Bernet, S., & Perez, M. (2012) · IEEE Industry Applications Magazine · doi:10.1109/mias.2012.2192231 · Cited by 332
Self-citationLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems
Choi, U.-M., Lee, K.-B., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2269531 · Cited by 257
Smet, V., Forest, F., Huselstein, J.-J., Rashed, A., & Richardeau, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196894 · Cited by 232
“For example, significant research has been, and continues to be, conducted in that field for converters and drives [7]–[13].”
BackgroundSelf-citationA Fault-Tolerant Single-Phase Five-Level Inverter for Grid-Independent PV Systems
A, M. R., & Sivakumar, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2455523 · Cited by 219
“The survey of fault-tolerant techniques for three-phase two-level and multilevel inverters is discussed in [18] and [19].”
BackgroundReliability Calculation of Multilevel Converters: Theory and Applications
Richardeau, F., & Pham, T. T. L. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2211315 · Cited by 212
Self-citationLi, J., Huang, A. Q., Liang, Z., & Bhattacharya, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143430 · Cited by 211
“However, in some critical industrial processes with high standstill cost and safety-aspect concern, a high reliability and survivability of the drive system is very important [5], [6].”
BackgroundRoshankumar, P., Rajeevan, P. P., Mathew, K., Gopakumar, K., Leon, J. I., & Franquelo, L. G. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2185714 · Cited by 200
“at reduced power level and, hence, this configuration is fault tolerant to some extent [17], [18].”
BackgroundA Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
“Since the MMC circuit is built based upon stacking up a large number of submodules (SMs), its operation is vulnerable to any SM failure [7].”
Background
Metadata
- Authors
- Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-07
- Volume
- 57
- Issue
- 7
- Pages
- 2207-2218
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2108048963
- Cited by
- 384
- References
- 31
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.