The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Abstract
In this paper, a novel failure-detection technique and its analog circuit for insulated gate bipolar transistors (IGBTs), under open- and short-circuit failures, are proposed. This technique is applied to a three-phase induction-motor (IM) drive system. The detection technique is adapted to detect failures of short-circuit and open-circuit in the IGBT, which is based on gate-signal monitoring. The most important issue of this technique is the reduction of time for fault detection. This is very important in a failure-tolerant IM drive based on the material-redundancy approach or protection systems since the detection must be done before the device is damaged, in approximately less than 10 μs. The experimental test and simulations are presented in order to validate the proposed fault-detection technique, and it is validated, achieving replacement of the damaged element in the most suitable time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Welchko, B. A., Lipo, T. A., Jahns, T. M., & Schulz, S. E. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830074 · Cited by 724
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Fault-tolerant drive-by-wire systems
(2002) · IEEE Control Systems · doi:10.1109/mcs.2002.1035218 · Cited by 387
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
A discussion on IGBT short-circuit behavior and fault protection schemes
Chokhawala, R. S., Catt, J., & Kiraly, L. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.370271 · Cited by 280
Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor
Bianchi, N., Bolognani, S., & Dai Pre, M. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900445 · Cited by 276
Hefner, A. R., & Blackburn, D. L. (1988) · Solid-State Electronics · doi:10.1016/0038-1101(88)90025-1 · Cited by 261
FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005244 · Cited by 245
Xiong, Y., Cheng, X., Shen, Z. J., Mi, C., Wu, H., & Garg, V. K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918399 · Cited by 226
Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis
Lezana, P., Aguilera, R., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2013845 · Cited by 215
Mendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213
Multiphase Power Converter Drive for Fault-Tolerant Machine Development in Aerospace Applications
de Lillo, L., Empringham, L., Wheeler, P. W., Khwan-On, S., Gerada, C., Othman, M. N., & Huang, X. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036026 · Cited by 198
Rothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Detection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems
Kim, T., Lee, W., & Hyun, D.-S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2019775 · Cited by 139
Failures-tolerance and remedial strategies of a PWM multicell inverter
Richardeau, F., Baudesson, P., & Meynard, T. A. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805588 · Cited by 133
Performance Evaluation of Fault-Tolerant Neutral-Point-Clamped Converters
Ceballos, S., Pou, J., Robles, E., Zaragoza, J., & Martín, J. L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026710 · Cited by 124 · cited 13×
“[6]–[10], multilevel inverter drives with bridge inverter cells implemented with IGBT modules [14], [15], or dual pack of IGBTs [16], [17] as redundant unit.”
BackgroundInfluentialAnalytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. W. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
IGBT Fault Protection Based on di/dt Feedback Control
Huang, F. H., & Flett, F. (2007) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2007.4342213 · Cited by 102
Failure mechanisms of IGBTs under short-circuit and clamped inductive switching stress
Trivedi, M., & Shenai, K. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737598 · Cited by 81
Barriuso, P., Dixon, J., Flores, P., & Moran, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005680 · Cited by 70
Switching voltage transient protection schemes for high-current IGBT modules
Chokhawala, R., & Sobhani, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.649974 · Cited by 55
An Integrated on-Line Motor Protection System
Farag, S. F., Bartheld, R. G., & Habetler, T. G. (1996) · IEEE Industry Applications Magazine · doi:10.1109/2943.485759 · Cited by 46
Short circuit analysis and protection of power module IGBTs
Pagano, R., Chen, Y., Smedley, K. M., Musumeci, S., & Raciti, A. (2005) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2005.1453063 · Cited by 37
Analytical investigation of an induction motor drive under inverter fault mode operations
Klíma, J. (2003) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20030122 · Cited by 36
A Fault-Tolerant Interconnect Mechanism for NMR Nanoarchitectures
Namazi, A., Nourani, M., & Saquib, M. (2009) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2009.2024779 · Cited by 20
A strategy to replace the damaged element for fault-tolerant induction motor drive
Rodriguez, M. A., Claudio, A., Theilliol, D., Vela, L. G., & Hernández-González, L. (2008) · International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE) · doi:10.1109/iceee.2008.4723458 · Cited by 16
Self-citation
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Oh, H., Han, B., McCluskey, P., Han, C., & Youn, B. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2346485 · Cited by 513
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“This may lead to secondary faults in the converter or in the remaining drive components, resulting in the total system shutdown and high repairing costs.”
BackgroundJi, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329
Metadata
- Authors
- Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1625-1633
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2099883498
- Cited by
- 264
- References
- 30
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.