Wind Energy System With Integrated Functions of Active Power Transfer, Reactive Power Compensation, and Voltage Conversion
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
As the power of wind energy system increases, the control of their active and reactive power becomes increasingly more important from a system standpoint given that these are typical frequency and voltage control parameters. In this paper, a family of wind energy systems with integrated functions of active power transfer, reactive power compensation, and voltage conversion is proposed. The proposed wind energy systems using solid-state transformer (SST) can effectively suppress the voltage fluctuation caused by the transient nature of wind energy without additional reactive power compensator and, as such, may enable the large penetration of wind farm (WF) into the power grid. To this end, a simulation study for WF driven by squirrel-cage induction generators is presented to verify the effectiveness of the proposed system. In addition, a modular-type high-voltage and high-power three-phase SST topology is presented for the proposed system, and its basic building block, which is a single-phase SST, is analyzed. The functions of SST in the presented wind energy system are verified in a single-phase laboratory prototype with scaled-down experiments. Lastly, cost issue of the proposed technology is analyzed with comparison to the traditional one.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Future Renewable Electric Energy Delivery and Management (FREEDM) System: The Energy Internet
Huang, A. Q., Crow, M. L., Heydt, G. T., Zheng, J. P., & Dale, S. J. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2081330 · Cited by 1,463 · cited 3×
“On the one hand, efforts are focused on topology investigation in this new technology for high-voltage and high-power application [12]–[15].”
BackgroundSelf-citationDynamic modeling of doubly fed induction generator wind turbines
Ekanayake, J. B., Holdsworth, L., Wu, X., & Jenkins, N. (2003) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2003.811178 · Cited by 733 · cited 1×
“Presently, there are three main WF architectures, namely, SCIG-based wind energy system [21], doubly fed induction generator (DFIG)-based wind energy system [22], and directly driven synchronous generator (DDSG)-based wind energy system [23], shown in Fig.”
BackgroundPwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundKrismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“Its dc/dc stage is embodied by a dual active bridge (DAB) converter, which represents the most attractive candidate for high-power applications requiring isolation, as it can perform zero-voltage switching in a wide operation range [25], [26].”
BackgroundGrid Integration of Large DFIG-Based Wind Farms Using VSC Transmission
Xu, L., Yao, L., & Sasse, C. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901306 · Cited by 428
Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Song, W., & Huang, A. Q. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036019 · Cited by 358 · cited 1×
“redundant design can be incorporated to achieve fault-tolerant operation [27].”
BackgroundSelf-citationA power electronic-based distribution transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997934 · Cited by 313
STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System
Han, C., Huang, A. Q., Baran, M. E., Bhattacharya, S., Litzenberger, W., Anderson, L., Johnson, A. L., & Edris, A.-A. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.888031 · Cited by 307
Self-citationA Power Electronic-Based Distribution Transformer
Ronan, E. R., Sudhoff, S. D., Glover, S. F., & Galloway, D. L. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4312081 · Cited by 264
Research works printed but not linked: 3
- 2011, Field Prototype Development of Intelligent Universal Transformer
- wang, 2011, Comparison of different control strategies for 20 KVA solid state transformer, Proc IEEE ECCE, 3173
- 2009, Wind Energy The Facts A Guide to the Technology Economics and Future of Wind Power
Cited by
Items 101–164 of 164
Jin, Z., & Kondo, K. (2024) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.24004655 · Cited by 6
Yousefpoor, N., Parkhideh, B., Azidehak, A., & Bhattacharya, S. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953801 · Cited by 8
“This solution is often called Solid-State Transformer (SST), [12-17].”
BackgroundJha, D., & Sharma, N. K. (2024) · doi:10.52710/ae.484 · Cited by 6
Lan, F., Li, T., Li, J., & Yao, Z. (2016) · China International Conference on Electricity Distribution (CICED) · doi:10.1109/ciced.2016.7576333 · Cited by 6
“With the rapid development of wind power technology and the increase of wind-turbine capacity, capturing the maximum power of wind turbine will play an important role in saving energy [1].”
BackgroundDesign of Three Phase Solid State Transformer Deployed within Multi-Stage Power Switching Converters
Tahir, U., Abbas, G., Glãvan, D. O., Bălaş, V. E., Farooq, U., Bǎlaş, M. M., Raza, A., Asad, M. U., & Gu, J. J. (2019) · Applied Sciences · doi:10.3390/app9173545 · Cited by 7
Haritha, G., Kumaravel, S., & Ashok, S. (2018) · 2018 2nd International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2018.8356290 · Cited by 5
“Depending on the type of DC-DC converters used, different circuit topologies of SST were proposed [2-6] of which the Dual Active Bridge (DAB) based SST is most widely used.”
MethodHardware-in-loop real-time simulation of a battery storage system in a wind generation scheme
Bazargan, D., & Filizadeh, S. (2013) · International Conference on Electric Power and Energy Conversion Systems · doi:10.1109/epecs.2013.6713090 · Cited by 5
Design and Development of Modular Multilevel Converter for Solid State Transformer Application
Kadandani, N. B. (2025) · BAYERO JOURNAL OF ENGINEERING AND TECHNOLOGY · doi:10.67607/nw1j6a35 · Cited by 8
Faiad, A. A., Hebala, O. M., Hamad, M. S., & Abdel-Khalik, A. S. (2021) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon50283.2021.9686211 · Cited by 5
Luhana, P. P., & Christian, A. N. (2017) · International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS) · doi:10.1109/icecds.2017.8389529 · Cited by 5
Three-phase AC-DC solid-state transformer for low-voltage DC power distribution applications
Joca, D. R., Barreto, L. H. S. C., Oliveira, D. S., & Pacheco, J. D. O. (2016) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2016.7874536 · Cited by 5
“In power transmission, high efficiency over long distances is possible associated to galvanic isolation and proper adjustment of voltage levels, which can be subsequently reduced to medium- or high-voltage distribution levels for industrial purposes, and low voltage for commercial and residential purposes [1].”
BackgroundConcepts, Configurations, and Challenges of Solid-State Transformer: A Review
Solanki, J. B., & Chudasama, K. J. (2022) · Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering) · doi:10.2174/2352096515666220707120302 · Cited by 8
Modeling and control of a cascaded multilevel converter‐based electronic power transformer
Huang, H. X., Zhang, J., Mao, C., Lu, J., & Wang, D. (2016) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22215 · Cited by 4
Dorrell, D. G. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049166 · Cited by 4
“They can also be used in power system schemes for wind [11] and traction [12], and also for UPS applications which were reviewed in [13].”
BackgroundOuyang, S., Liu, J., Song, S., Chen, X., Yang, Y., & Wu, H. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8913205 · Cited by 4
“Till now, research on and prototypes of SSTs have been reported majorly on traction[2] and distribution grid[3][4].”
BackgroundSomkun, S., & Chunkag, V. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392441 · Cited by 4
“, active rectifiers [1], power quality improvement [2], distributed generation [3], and recently in battery chargers of electric vehicles [4], and solid state transformers [5].”
BackgroundA Bidirectional Double Uneven Power Converter Based DC–DC Converter for Solid-State Transformers
Park, K., & Lee, K. (2018) · Electronics · doi:10.3390/electronics7110334 · Cited by 4
“In the literature, a dual active bridge (DAB) dc-dc converter with phase-shift control has been introduced as the most attractive candidate for high-power applications requiring isolation, low switching loss, and bidirectional power flow [3].”
BackgroundLiu, C., Zhi, Y., Zhang, Y., & Cai, G. (2016) · Asia-Pacific Power and Energy Engineering Conference (APPEEC) · doi:10.1109/appeec.2016.7779535 · Cited by 3
“Additionally, the cascaded H-bridge converter topology can be adopted in [4], which has been widely used because of its modularity to achieve medium-voltage output and good power quality; However, it also has many disadvantages such as the DC voltage unbalance at different phases and the DC voltage unbalance at differ…”
BackgroundJoca, D. R., Barreto, L. H. S. C., Oliveira, D. S., Vannier, J. C., Džonlaga, B., & Quéval, L. (2018) · Eletrônica de Potência · doi:10.18618/rep.2018.4.0007 · Cited by 2
Vijay Rama Raju, V., Doddi, B., Dixit, S., & Lingam, B. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202343001002 · Cited by 2
“A good way to maintain the network's voltage is by reactive power compensation.”
BackgroundJin, Z., & Kondo, K. (2024) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.23013867 · Cited by 2
Reserved-Energy-Aided Control in Solid-State Transformers
Sarda, R., Rodríguez, E., Farivar, G. G., Pou, J., Li, Y. H., Vaisambhayana, S., & Tripathi, A. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3547155 · Cited by 2
Impacts of FACTS device on wind farm protection: Comparison between STATCOM and UPFC
Gautam, S., Pang, C., & Yang, L. (2014) · International Conference on Information and Automation for Sustainability (ICIAfS) · doi:10.1109/iciafs.2014.7069621 · Cited by 2
“Numerous researchers have conducted the analysis based on the wind farm and wind energy generation, with publication various technical papers on the subject of wind farm protection [7-9, 13, 14, 17].”
BackgroundModular power electronic transformer and its direct power control
Tu, C., Zheng, L. X., Shuai, Z., Xiao, F., Jiang, F., & Hu, C. (2017) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2017.8282959 · Cited by 2
“In [15], a high-voltage and high-power topology is presented for wind energy system with integrated functions of active power transfer, reactive power compensation and voltage conversion.”
BackgroundKumar, G., & singh, S. (2018) · IEEE International Conference on Recent Advances and Innovations in Engineering (ICRAIE) · doi:10.1109/icraie.2018.8710389 · Cited by 2
Pumped-Storage Hydropower Operation Scheduling Method for Net Load Ramp Leveling
Tanabe, R., & Yokoyama, A. (2019) · doi:10.1109/ptc.2019.8810764 · Cited by 2
Arrizabalaga, A., Mazuela, M., Idarreta, A., Iraola, U., & Aizpuru, I. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255266 · Cited by 2
A Simplified Solid-State Transformer Model for Teaching Basic Concepts and Ideas
Smith, C. W. (2021) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm46819.2021.9637878 · Cited by 2
“Many of the references consulted for this paper listed voltage regulation as one of the potential benefits of the SST [4], [5], [6], [11]- [13].”
BackgroundPolat, U., & Yıldırım, D. (2022) · Global Energy Conference (GEC) · doi:10.1109/gec55014.2022.9987072 · Cited by 2
“Among the various kinds of renewable energy sources as an alternative for power generation, wind energy is by far the fast-growing renewable energy due to its free availability, environmentally friendly, policy fostering, and the maturity of turbine techniques, relatively economically competitive, and has become a res…”
BackgroundPower Quality Control Strategy of MMC Rectifier as Solid State Transformer in MVAC Network
Mangunkusumo, K. G. H., Ridwan, M., Sriyono, Wijaya, F. D., Irnawan, R., Sidik, Y. F., & Oktarina, P. P. (2023) · IEEE International Conference in Power Engineering Applications (ICPEA) · doi:10.1109/icpea56918.2023.10093220 · Cited by 2
“These assets make SST a promising technology in future smart grids at any voltage and power level [11].”
BackgroundVirtual Transformer Operation of Solid State Transformer (SST)
Qian, T. A. O., Ma, J., Zhu, M., Wen, S., Duan, Q., & Sha, G. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9254936 · Cited by 1
Sizing of a Reactive Power Compensation Device for a 300MW Grid Connected Wind Plant
Jayasudha, J., Vishakh, K. H., Nair, M. G., Pisini, J. K., & Thomas, A. (2025) · International Conference on Multidisciplinary Research and Innovations in Engineering (MRIE) · doi:10.1109/mrie66930.2025.11156630 · Cited by 1
“These primarily occur because of the random and unpredictable nature of wind, which affects the system’s capability to provide reactive power balance and voltage stability [4] [5] [6] [7].”
Xi, X., Shi, Z., Xing, C., Tian, X., Na, J., & Huang, Y. (2026) · Journal of Control and Decision · doi:10.1080/23307706.2026.2628204 · Cited by 1
Wind energy literature survey no. 30
Henriksen, L. C. (2013) · Wind Energy · doi:10.1002/we.1673 · Cited by 1
Ouyang, S., Liu, J., Song, S., & Wang, X. (2015) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec.2015.7361616 · Cited by 1
Gupta, N., & Singh, Y. (2017) · International Journal of ADVANCED AND APPLIED SCIENCES · doi:10.21833/ijaas.2017.06.007 · Cited by 1
“Also it offers easy tenability, design simplicity and performance stoutness (She et al., 2013; Arani and El-Saadany, 2013; Komatsu et al., 2001).”
BackgroundResearch on collaborative regulation strategy of intelligent power equipment group
Chen, S., Yan, H., Ruan, W., Liu, D., Sun‡, Y., & Li, B. (2017) · International Conference on Power and Renewable Energy (ICPRE) · doi:10.1109/icpre.2017.8390608 · Cited by 1
Modified Inverter Control for DFIG-Based System on DC Microgrid
Shukla, A., & Sharma, R. (2018) · International Conference on Intelligent Computing and Control Systems (ICICCS) · doi:10.1109/iccons.2018.8663185 · Cited by 1
High-Power-Density Converter for Renewable Energy Application
Lyu, X. (2017) · Cited by 1
Double Closed-Loop Control Strategy for Electric Springs Based on PI Controller
Zou, Y., Xu, S., & Chen, M. Z. Q. (2019) · International Conference on Information, Cybernetics, and Computational Social Systems (ICCSS) · doi:10.1109/iccss48103.2019.9115468 · Cited by 1
Li, X., Liu, C., Wang, M., Wang, Y., Pei, Z., & Kou, L. (2020) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia48364.2020.9367783 · Cited by 1
“(a) Traditional DFIG wind turbine (b) Configuration suggested in [8] (c) Configuration suggested in [9] (d) Configuration of proposed system”
BackgroundMethodResearch on Reactive Power Compensation Configuration of Wind Farm Integration
Wang, J., Chen, C., Zhang, S., Ren, Z., Chen, X., & Wang, X. (2021) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-80531-9_12 · Cited by 1
Tanabe, R., & Yokoyama, A. (2021) · IEEE PowerTech Conference · doi:10.1109/powertech46648.2021.9494899 · Cited by 1
Power Quality Control Strategy of MMC Inverter as Solid State Transformer on Distribution Network
Mangunkusumo, K. G. H., Ridwan, M., Sriyono, Irnawan, R., Sidik, Y. F., & Wijaya, F. D. (2023) · International Conference on High Voltage Engineering and Power Systems (ICHVEPS) · doi:10.1109/ichveps58902.2023.10257498 · Cited by 1
“In the future smart grid, SST is proposed as a promising technology to provide a good power quality at any voltage and power level [19].”
BackgroundLuhana, P. P., & Shah, M. J. (2016) · International Conference on Electrical, Electronics, and Optimization Techniques · doi:10.1109/iceeot.2016.7754825 · Cited by 1
“Global installed capacity increased from 40 000 MW at the end of 2003 to 94 000 MW at the end of 2007, at an average annual growth rate of nearly 25% [1], [2] [3].”
BackgroundJung, G.-E., Dinh, M.-C., Sung, H.-J., Lee, J.-I., & Park, M. (2019) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera47325.2019.8997074 · Cited by 1
“As the penetration rate of wind power generator in existing power systems increases, there are new technical difficulties related to system stability [4].”
Background2013 Index IEEE Transactions on Industrial Electronics Vol. 60
(2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2281744 · Cited by 1
Research on Wind Energy Integration in Matsu Islands
Wu, Y., Tseng, Y. C., Chen, B. K., Lee, D. J., & Huang, Y. C. (2014) · Advanced materials research · doi:10.4028/www.scientific.net/amr.953-954.369
Shahani, A. (2013) · University of Minnesota Digital Conservancy (University of Minnesota)
Dynamic Estimators for Islanding Detection in IEEE 9-Bus Wireless System
Paul, A., Vijayakumar, P., & Shijitha, R. (2016) · Wireless Personal Communications · doi:10.1007/s11277-016-3483-6
“The main concept of detecting an islanding situation is to monitor the DG output parameters, and decide whether an islanding situation has occurred from revolutionize in these parameters [6].”
BackgroundPower quality coefficients for power electronic transformers
Chirkova, G. V., & Zinoviev, G. S. (2016) · International Conference of Young Specialists on Micro/Nanotechnologies and Electron Devices · doi:10.1109/edm.2016.7538805 · Cited by 1
Long-distance distribution line compensation using power electronic transformer
Ouyang, S., Liu, J., Song, S., & Chen, X. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846199
“In the past years, the reactive power compensation of PET is studied on: PCC point reactive power control of wind power system [2]; node voltage regulation in the power distribution system [3][4]; loss minimization of the power distribution system [5].”
BackgroundSolid State Transformer in Wind Energy Conversion System with Hybrid Renewable Energy System
Immanuel, I. P. K. (2017) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2017.8267
Prince, M. K. K., Arif, M. T., Gargoom, A., Saha, S., Oo, M. A. T., & Haque, M. E. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379825
“isolation, higher cost, lack of modularity and protection issues, researchers in [3] and [5] implemented three phase three stage SST topology with a squirrel cage induction generator (SCIG) and doubly fed induction generator (DFIG) respectively.”
BackgroundSiC erdieroaleak energia eolikoan LCoEa hobetzeko
Arrizabalaga, A., Mazuela, M., Arocena, J. U., & Oiartzabal, J. A. (2021) · I. Ikergazte: Nazioarteko ikerketa euskaraz. Kongresuko artikulu-bilduma · doi:10.26876/ikergazte.iv.03.02
Solid-state transformer and magnetic properties with potential topologies
Li, Y., Yang, M., & Bahman, A. S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-85622-5.00009-2
Hashim, T. T., & Kalem, Ş. (2024) · Al Rafidain Journal of Engineering Sciences · doi:10.61268/mqayrh16
Cường, T. H., Nguyen, N. T., & Anh, A. T. H. T. (2025) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijece.v15i2.pp1463-1472
“Reactive power compensation solutions have been widely researched and focused on directions such as two-way compensation, fixed compensation, or flexible compensation using synchronous compensators, capacitors, and static var compensator (SVC) [10]–[12].”
A SYSTEMATIC LITERATURE REVIEW ON ENERGY-EFFICIENT TRANSFORMER DESIGN FOR SMART GRIDSPreprint
Bajwa, A. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5234687 · Cited by 2
Mansour, M., & Bhattacharya, I. (2025) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm52009.2025.11225345
Multirate EMT Simulation of Power Electronic Transformers With High-Precision Firing Signals
Wang, H., Xu, J., & Feng, M. (2026) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2026.3656907
“P OWER electronic transformers (PETs) have garnered significant interest in modern power systems owing to their superior capabilities in efficient and flexible energy conversion with the large scale integration of distributed energy resources and renewable energy sources into power grids [1].”
Joca, D. R. (2019) · theses.fr (ABES) · doi:10.70675/2f000a7azc807z495bzac0bza1d5bb417a5a · Cited by 1
Design and Simulation of Marine Hybrid Series Medium Voltage Solid-State Transformer
Li, S., Wang, S., Liang, Q., Wu, F., Cheng, Z., & Liu, X. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-7652-4_43
Zhang, J., Wen, C., Wang, D., Chen, Y., Liu, S., Gao, T., & Li, X. (2026) · Electronics · doi:10.3390/electronics15132839 · Cited by 1
Metadata
- Authors
- She, X., Huang, A. Q., Wang, F., & Burgos, R.
- Affiliations
- North Carolina State University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 4512-4524
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2000794749
- Cited by
- 161
- References
- 30
- Citations by year
- 2026: 4 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 11 · 2020: 13 · 2019: 13 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 17 · 2014: 22 · 2013: 10
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Science Foundation
- North Carolina State University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Energy › Energy Engineering and Power Technology › Power Systems and Renewable Energy
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- wind energy systems, solid-state transformer, reactive power compensation, active power transfer, voltage conversion, voltage fluctuation suppression, grid integration of wind power, squirrel cage induction generator, voltage and frequency regulation, cost analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.