The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Abstract
This paper presents a wireless power transfer (WPT) system for powering implantable biomedical devices; the system is configured to achieve high efficiency even with CMOS switches and printed-circuit-board pattern coils and to maintain constant output voltage against coupling and loading variations without any additional blocks. It is shown that the parallel-resonant transmitter (TX) and receiver (RX) topology is advantageous for high efficiency even with lossy but compact components. In addition, the output voltage of the topology is insensitive to coupling and/or loading variations if the operating frequency is automatically adjusted according to coupling variations. A parallel-resonant class-D oscillator TX is developed to track the optimum operating frequency for the constant output voltage. The operating distance for the constant output voltage is also extended using a novel resonator structure, which contains two resonating coils. These proposed schemes allow a compact, efficient, and robust wireless power system. Maximum power of 174 mW can be transmitted with 63% overall efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The electrical parameters for blood can be found in [28].”
BackgroundSample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
A Frequency Control Method for Regulating Wireless Power to Implantable Devices
Si, P., Hu, A. P., Malpas, S., & Budgett, D. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918284 · Cited by 582
Low, Z. N., Chinga, R. A., Tseng, R., & Lin, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2010110 · Cited by 528
High-Misalignment Tolerant Compensation Topology For ICPT Systems
Villa, J. L., Sallan, J., Sanz Osorio, J. F., & Llombart, A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2161055 · Cited by 467
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Circuit-Model-Based Analysis of a Wireless Energy-Transfer System via Coupled Magnetic Resonances
Cheon, S., Kim, Y.-H., Kang, S.-Y., Lee, M. L., Lee, J.-M., & Zyung, T. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2072893 · Cited by 395
Effect of Coupling Between Multiple Transmitters or Multiple Receivers on Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196902 · Cited by 382
Self-citationA Study on Magnetic Field Repeater in Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188254 · Cited by 351
Self-citationCircuit Model Based Analysis of a Wireless Energy Transfer System via Coupled Magnetic Resonances
Cheon, S.-H., Kim, Y.-H., Lee, M.-L., & Kang, S.-Y. (2011) · The Transactions of the Korean Institute of Power Electronics · doi:10.6113/tkpe.2011.16.2.137 · Cited by 337
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Contactless Energy Transfer System With FPGA-Controlled Resonant Converter
Moradewicz, A. J., & Kazmierkowski, M. P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2051395 · Cited by 270
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Guo, S., & Lee, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020195 · Cited by 253
Analysis, Design, and Control of a Transcutaneous Power Regulator for Artificial Hearts
Chen, Q., Wong, S. C., Tse, C. K., & Ruan, X. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2006492 · Cited by 244
An optimal design methodology for inductive power link with class-E amplifier
Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.846208 · Cited by 222
Zierhofer, C. M., & Hochmair, E. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55682 · Cited by 214
Investigation of Adaptive Matching Methods for Near-Field Wireless Power Transfer
Park, J., Tak, Y., Kim, Y., Kim, Y., & Nam, S. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2123061 · Cited by 194
Closed-loop class E transcutaneous power and data link for MicroImplants
Troyk, P. R., & Schwan, M. A. K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141197 · Cited by 177
Inductive Power Link for a Wireless Cortical Implant With Two-Body Packaging
Silay, K. M., Dehollain, C., & Declercq, M. J. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2170676 · Cited by 59
High performance 3-coil wireless power transfer system for the 512-electrode epiretinal prosthesis
Zhao, Y., Nandra, M. S., Yu, C., & Tai, Y. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347503 · Cited by 25
The Class-E Concept For Efficient Wide-Band Coupling-Insensitive Transdermal Power And Data Transfer
Zierhofer, & Hochmair (1992) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1992.595606 · Cited by 11
Cited by
Wireless Power Transfer—An Overview
Zhang, Z., Pang, H., Georgiadis, A., & Cecati, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835378 · Cited by 1,723
Wireless Charging Technologies: Fundamentals, Standards, and Network Applications
Lu, X., Wang, P., Niyato, D., Kim, D. I., & Han, Z. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2499783 · Cited by 968
Li, H., Li, J., Wang, K., Chen, W., & Yang, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2349534 · Cited by 592
Development of 1-MW Inductive Power Transfer System for a High-Speed Train
Kim, J. H., Lee, B.-S., Lee, J.-H., Lee, S.-H., Park, C.-B., Jung, S.-M., Lee, S.-G., Yi, K.-P., & Baek, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417122 · Cited by 482
Mai, R., Liu, Y., Li, Y., Yue, P., Cao, G., & He, Z. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665040 · Cited by 360
Metadata
- Authors
- Ahn, D., & Hong, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-05
- Volume
- 61
- Issue
- 5
- Pages
- 2225-2235
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2131837022
- Cited by
- 315
- References
- 24
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.