A Voltage-Based Approach Without Extra Hardware for Open-Circuit Fault Diagnosis in Closed-Loop PWM AC Regenerative Drives

Freire, Nuno M. A., Estima, Jorge O., Cardoso, Antonio J. M. · 2014 · IEEE Transactions on Industrial Electronics

Abstract

The widespread use of electric drives has led to an increasing interest in their condition monitoring and fault diagnostics. With respect to power-switch open-circuit fault diagnosis, the majority of the proposed voltage-based approaches require additional hardware, increasing the system cost. As a result, industry acceptance may be low. This paper proposes a new voltage-based approach-without additional sensors-for open-circuit fault diagnosis in closed-loop controlled pulsewidth-modulation (PWM) ac voltage source converters, by using the information contained in the reference voltages available from the control system. The robustness against false alarms of the proposed technique is improved by employing a voltage observer, in order to estimate the actual converter voltages. It has been proven that the algorithm is insensitive to parameter errors; thus, its effectiveness is not compromised. In order to assess the applicability of the diagnostic technique, it is integrated into the control system of a permanent-magnet-synchronous-machine drive, with regenerative capabilities, together with three of the most widely used PWM control strategies: hysteresis current control, direct torque control, and space vector modulation. The technique performance is analyzed in detail by means of several experimental results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2013.2279383

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 25

  1. abramik, 2003, A diagnostic method for on-line fault detection and localization in VSI-fed ac drives, Proc Eur Conf Power Electron Appl, 8
  2. 10.1109/TIE.2009.2023640 · DOI · Paper page
  3. 10.1109/TIA.2011.2168800 · DOI · Paper page
  4. 10.1109/DEMPED.2011.6063654 · DOI
  5. 10.1109/TIE.2012.2207655 · DOI · Paper page
  6. 10.1109/TPEL.2003.809351 · DOI · Paper page
  7. 10.1109/TIE.2008.2005244 · DOI · Paper page
  8. 10.1109/TPEL.2010.2052472 · DOI · Paper page
  9. 10.1049/iet-epa.2011.0315 · DOI
  10. mendes, 1998, voltage source inverter fault diagnosis in variable speed ac drives, by park's vector approach, Seventh International Conference on Power Electronics and Variable Speed Drives (IEE Conf Publ No 456), 538, 10.1049/cp:19980607 · DOI
  11. 10.1109/WEMDCD.2013.6525187 · DOI
  12. 10.1109/TIA.2011.2124436 · DOI · Paper page
  13. 10.1109/TEC.2005.847961 · DOI · Paper page
  14. 10.1109/IEMDC.1999.769220 · DOI · Paper page
  15. 10.1109/28.739017 · DOI · Paper page
  16. 10.1109/TIE.2007.911951 · DOI · Paper page
  17. 10.1109/ICELMACH.2010.5608044 · DOI
  18. 10.1049/iet-rpg.2008.0060 · DOI · Paper page
  19. 10.1109/TPEL.2012.2212916 · DOI · Paper page
  20. 10.1109/TIE.2010.2098355 · DOI · Paper page
  21. 10.1109/ICElMach.2012.6350216 · DOI
  22. 10.1109/28.273627 · DOI · Paper page
  23. 10.1109/TIE.2010.2047829 · DOI · Paper page
  24. 10.1109/TIA.2004.834049 · doi:10.1109/tia.2004.834049
  25. 10.1109/TPEL.2003.818833 · doi:10.1109/tpel.2003.818833

Cited by

See all 167

Metadata

Authors
Freire, N. M. A., Estima, J. O., & Cardoso, A. J. M.
Venue
IEEE Transactions on Industrial Electronics
Published
2014-09
Volume
61
Issue
9
Pages
4960-4970
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W1970115563
Cited by
167
References
2
FWCI
8.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.