A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
This paper provides a comprehensive survey on the state-of-the-art condition monitoring and fault diagnostic technologies for wind turbines (WTs). The Part I of this survey briefly reviews the existing literature surveys on the subject, discusses the common failure modes in the major WT components and subsystems, briefly reviews the condition monitoring and fault diagnostic techniques for these components and subsystems, and specifically discusses the issues of condition monitoring and fault diagnosis for offshore WTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 2×
“It has been proposed to use thermo-sensitive electrical parameters, such as the collector-emitter saturation voltage VCE(sat), on-state resistance, gate-emitter threshold voltage, and internal thermal resistance Rth, to monitor the degradation of IGBT modules [61].”
BackgroundMethodCondition monitoring and fault detection of wind turbines and related algorithms: A review
Hameed, Z., Hong, Y. S., Cho, Y. M., Ahn, S. H., & Song, C. K. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.05.008 · Cited by 995
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Survey of Failures in Wind Power Systems With Focus on Swedish Wind Power Plants During 1997–2005
Ribrant, J., & Bertling, L. M. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889614 · Cited by 757
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
A review of recent advances in wind turbine condition monitoring and fault diagnosis
Lu, B., Li, Y., Wu, X., & Yang, Z. (2009) · IEEE Power Electronics and Machines in Wind Applications (PEMWA) · doi:10.1109/pemwa.2009.5208325 · Cited by 584
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Online wind turbine fault detection through automated SCADA data analysis
Zaher, A., McArthur, S. D. J., Infield, D. G., & Patel, Y. (2009) · Wind Energy · doi:10.1002/we.319 · Cited by 464
Cited by
Lei, Y., Jia, F., Lin, J., Xing, S., & Ding, S. X. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2519325 · Cited by 1,191
Multiscale Convolutional Neural Networks for Fault Diagnosis of Wind Turbine Gearbox
Jiang, G., He, H., Yan, J., & Xie, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844805 · Cited by 892
Machine Learning in Predictive Maintenance towards Sustainable Smart Manufacturing in Industry 4.0
Çınar, Z. M., Abdussalam Nuhu, A., Zeeshan, Q., Korhan, O., Asmael, M., & Safaei, B. (2020) · Sustainability · doi:10.3390/su12198211 · Cited by 834
Data-Driven Methods for Predictive Maintenance of Industrial Equipment: A Survey
Zhang, W., Yang, D., & Wang, H. (2019) · IEEE Systems Journal · doi:10.1109/jsyst.2019.2905565 · Cited by 732
Vibration based condition monitoring and fault diagnosis of wind turbine planetary gearbox: A review
Wang, T., Han, Q., Chu, F., & Feng, Z. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.02.051 · Cited by 571
Liu, Z., & Zhang, L. (2020) · Measurement · doi:10.1016/j.measurement.2019.107002 · Cited by 535
Damage detection techniques for wind turbine blades: A review
Du, Y., Zhou, S., Jing, X., Peng, Y., Wu, H., & Kwok, N. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106445 · Cited by 463
Using SCADA data for wind turbine condition monitoring – a review
Tautz‐Weinert, J., & Watson, S. J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0248 · Cited by 458
Deep Learning-Based Intelligent Fault Diagnosis Methods Toward Rotating Machinery
Tang, S., Yuan, S., & Zhu, Y. (2020) · IEEE Access · doi:10.1109/access.2019.2963092 · Cited by 323
Badihi, H., Zhang, Y., Jiang, B., Pillay, P., & Rakheja, S. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3171691 · Cited by 319
Automatic Detection of Wind Turbine Blade Surface Cracks Based on UAV-Taken Images
Wang, L., & Zhang, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2682037 · Cited by 298
Wind Turbine Fault Detection Using a Denoising Autoencoder With Temporal Information
Jiang, G., Xie, P., He, H., & Yan, J. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2759301 · Cited by 288
An Overview on Fault Diagnosis, Prognosis and Resilient Control for Wind Turbine Systems
Gao, Z., & Liu, X. (2021) · Processes · doi:10.3390/pr9020300 · Cited by 281
Deep transfer learning with limited data for machinery fault diagnosis
Han, T., Liu, C., Wu, R., & Jiang, D. (2021) · Applied Soft Computing · doi:10.1016/j.asoc.2021.107150 · Cited by 268
Condition Monitoring of Wind Turbine Generators Using SCADA Data Analysis
Jin, X., Xu, Z., & Qiao, W. (2021) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2020.2989220 · Cited by 209
Self-citationAn incorrect data detection method for big data cleaning of machinery condition monitoring
Xu, X., Lei, Y., & Li, Z. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2903774 · Cited by 134
Lu, L., He, Y., Wang, T., Shi, T., & Ruan, Y. (2019) · IEEE Access · doi:10.1109/access.2019.2936228 · Cited by 35
“In existing studies [2], [22], there are usually wired accelerometer sensors adopted to collect vibration signals.”
Background
Metadata
- Authors
- Qiao, W., & Lu, D.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-10
- Volume
- 62
- Issue
- 10
- Pages
- 6536-6545
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1605077306
- Cited by
- 533
- References
- 42
- FWCI
- 39.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.