Stator Fault Diagnostics in Squirrel Cage Three-Phase Induction Motor Drives Using the Instantaneous Active and Reactive Power Signature Analyses
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
In this paper, the instantaneous active and reactive power signature analyses are presented for stator fault diagnosis in operating squirrel cage three-phase induction motors either directly connected to the mains or fed from inverters. Both simulation and experimental results are presented to show the effectiveness and the merits of the proposed approach that offers the possibility to detect this type of fault and to discriminate it from other abnormality conditions responsible for the same motor behavior by comparing the signature analyses of the two considered quantities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706 · cited 1×
“The open-circuit fault does not occur so often in the induction motors [10], [11].”
BackgroundReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602 · cited 4×
“The latter is considered as the most severe one, which can cause substantial and irreversible damage to the stator winding and core [1]–[12].”
BackgroundInfluentialCause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
Bonnett, A. H., & Soukup, G. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148460 · Cited by 593
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Recent developments of induction motor drives fault diagnosis using AI techniques
Filippetti, F., Franceschini, G., Tassoni, C., & Vas, P. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873207 · Cited by 511
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors
Bonnett, A. K., & Soukup, G. C. (2002) · Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference · doi:10.1109/papcon.1991.239667 · Cited by 489
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489 · cited 1×
“To computationally simulate the electromechanical behavior of the squirrel cage three-phase induction motor under stator winding fault conditions, a transient multiloop model of an induction machine is used as described in [13], [54], and [55].”
MethodThe detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471 · cited 10×
“Most of the proposed strategies are very sensitive to supplyvoltage unbalance or to the stator inherent asymmetries both in the machine (motor nonidealities) and instrumentation; therefore, the distinction between the healthy case and the faulty one is still a difficult task andmore research work is requested [8]–[13].”
BackgroundMethodInfluentialCruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Self-citationDetection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“A substantial amount of research has been conducted in the last decades to diagnose stator winding faults in inductionmotordrive systems [5]–[45], such as those based on the analysis of vibration [14], axial leakage flux [15], [16], and stray flux [17].”
BackgroundThorsen, O. V., & Dalva, M. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464536 · Cited by 344
A High-Resolution Frequency Estimation Method for Three-Phase Induction Machine Fault Detection
Kia, S. H., Henao, H., & Capolino, G.-A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899826 · Cited by 325
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
Marques Cardoso, A. J., Cruz, S. M. A., & Fonseca, D. S. B. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.790920 · Cited by 315
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines
Bachir, S., Tnani, S., Trigeassou, J.-C., & Champenois, G. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.874258 · Cited by 287
Induction Machine Condition Monitoring Using Neural Network Modeling
Su, H., & Chong, K. T. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888786 · Cited by 271
da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.909060 · Cited by 266 · cited 1×
“As a noninvasive technique, the spectral analysis of the motor current was proposed to detect unbalances (asymmetries) of the machine such as detecting the negative-sequence current component [13], [18]–[20], negative-sequence impedances [21], [22], or even for temperature monitoring [23], [24].”
MethodThorsen, O. V., & Dalva, M. (2002) · Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94) · doi:10.1109/pcicon.1994.347637 · Cited by 264
Cruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258 · cited 3×
“As reported in [26], the stator fault not only induces a negative sequence component in the stator current but also increase the positive sequence, which means that the active and reactive powers do not remain the same as in the healthy case as aforementioned, but increase accordingly to that.”
BackgroundInfluentialBallal, M. S., Khan, Z. J., Suryawanshi, H. M., & Sonolikar, R. L. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888789 · Cited by 251
Lee, S. B., Tallam, R. M., & Habetler, T. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810848 · Cited by 248
Martins, J. F., Pires, V. F., & Pires, A. J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888790 · Cited by 219
Monitoring of defects in induction motors through air-gap torque observation
Hsu, J. S. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464514 · Cited by 217
Diagnosis of Stator Inter-Turn Short Circuits in DTC Induction Motor Drives
Cruz, S. M. A., & Cardoso, A. J. M. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.834012 · Cited by 185 · cited 1×
“Although the controller tends to compensate for the faults and minimize their impact on the system outputs [27], [43], the effect of the fault is still clearly visible in the spectra of the considered quantities.”
BackgroundSelf-citationBouzid, M., Champenois, G., Bellaaj, N. M., Signac, L., & Jelassi, K. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004667 · Cited by 179 · cited 1×
“Also it is stated in [36] that the phase angles decreasewith the extension of the stator fault, whichmodifies the motor power factor.”
BackgroundInduction machine condition monitoring with higher order spectra
Arthur, N., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873211 · Cited by 170
Current monitoring for detecting inter-turn short circuits in induction motors
Stavrou, A., Sedding, H. G., & Penman, J. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.911400 · Cited by 168
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344) · doi:10.1109/ias.2002.1043741 · Cited by 167
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811784 · Cited by 163
Nandi, S., & Toliyat, H. A. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.980363 · Cited by 160 · cited 1×
“Inter-turn fault detection has also been addressed in [28] and [29] through monitoring the presence of certain rotor-slot and residual saturation-related harmonics at the terminal voltage of the machine immediately after switch-OFF of the stator winding.”
BackgroundCruz, S. M. A., & Cardoso, A. J. M. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847975 · Cited by 158
Self-citationCheng, S., Zhang, P., & Habetler, T. G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064276 · Cited by 149 · cited 1×
“As a noninvasive technique, the spectral analysis of the motor current was proposed to detect unbalances (asymmetries) of the machine such as detecting the negative-sequence current component [13], [18]–[20], negative-sequence impedances [21], [22], or even for temperature monitoring [23], [24].”
MethodA Detailed Model of Induction Machines With Saturation Extendable for Fault Analysis
Nandi, S. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.834101 · Cited by 139 · cited 1×
“To computationally simulate the electromechanical behavior of the squirrel cage three-phase induction motor under stator winding fault conditions, a transient multiloop model of an induction machine is used as described in [13], [54], and [55].”
MethodDrif, M., & Cardoso, A. J. M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2161252 · Cited by 104 · cited 10×
“In this way, their spectra are clear from any component at the fundamental supply frequency or its multiples, making themmore useful to detect the specific components directly related to the stator fault conditions at the disturbance frequency [47]–[49].”
BackgroundMethodResultInfluentialSelf-citationDetection of Stator Faults in Induction Machines Using Residual Saturation Harmonics
Nandi, S. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.880838 · Cited by 83 · cited 1×
“Inter-turn fault detection has also been addressed in [28] and [29] through monitoring the presence of certain rotor-slot and residual saturation-related harmonics at the terminal voltage of the machine immediately after switch-OFF of the stator winding.”
BackgroundOn innovative methods of induction motor interturn and broken-bar fault diagnostics
Mirafzal, B., & Demerdash, N. A. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.870038 · Cited by 81
Interturn Fault Diagnosis in Induction Motors Using the Pendulous Oscillation Phenomenon
Mirafzal, B., Povinelli, R. J., & Demerdash, N. A. O. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.853767 · Cited by 66
An Advanced Stator Winding Insulation Quality Assessment Technique for Inverter-Fed Machines
Yang, J., Cho, J., Lee, S. B., Yoo, J.-Y., & Kim, H.-D. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.916753 · Cited by 65 · cited 2×
“Furthermore, some proposals combining the previousmethodswith artificial intelligence, transient, time-frequency analysis, and other signal processing techniques and parameter estimation ones have also been proposed, even when the motor is fed by an inverter [32]–[45].”
BackgroundKallesøe, C. S., Izadi‐Zamanabadi, R., Vadstrup, P., & Rasmussen, H. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900494 · Cited by 55
Wu, Q. H., & Nandi, S. (2008) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/08ias.2008.25 · Cited by 38 · cited 1×
“In [52], stator line currents of a three-phase star-connected induction machine were decomposed into positive- and negative-sequence components.”
MethodDigital Signal Processing for Induction Machines Diagnosis - A Review
Kia, S. H., Henao, H., & Capolino, G. (2007) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2007.4460325 · Cited by 30
Cited by
Fault Diagnosis for Electrical Systems and Power Networks: A Review
Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2987321 · Cited by 296
Motor Fault Diagnostics Based on Current Signatures: A Review
Niu, G., Dong, X., & Chen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285999 · Cited by 269
A deep learning approach for fault diagnosis of induction motors in manufacturing
Shao, S.-Y., Sun, W.-J., Yan, R.-Q., Wang, P., & Gao, R. X. (2017) · Chinese Journal of Mechanical Engineering · doi:10.1007/s10033-017-0189-y · Cited by 167
“Therefore, proper grasping of data reflecting the working states of induction motors can obtain early identification of potential failures [4].”
Pietrzak, P., & Wolkiewicz, M. (2021) · Electronics · doi:10.3390/electronics10151786 · Cited by 54
Fault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Metadata
- Authors
- Drif, M., & Cardoso, A. J. M.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2014-05
- Volume
- 10
- Issue
- 2
- Pages
- 1348-1360
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2047110850
- Cited by
- 235
- References
- 49
- FWCI
- 21.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.