ECG Authentication for Mobile Devices
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Traditional mobile login methods, like numerical or graphical passwords, are vulnerable to passive attacks. It is common for intruders to gain access to personal information of their victims by watching them enter their passwords into their mobile screens from a close proximity. With this in mind, a mobile biometric authentication algorithm based on electrocardiogram (ECG) is proposed. With this algorithm, the user will only need to touch two ECG electrodes (lead I) of the mobile device to gain access. The algorithm was tested with a cell phone case heart monitor in a controlled laboratory experiment at different times and conditions with ten subjects and also with 73 records obtained from the Physionet database. The obtained results reveal that our algorithm has 1.41% false acceptance rate and 81.82% true acceptance rate with 4 s of signal acquisition. To the best of our knowledge, this is the first approach on mobile authentication that uses ECG biometric signals and it shows a promising future for this technology. Nonetheless, further improvements are still needed to optimize accuracy while maintaining a short acquisition time for authentication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 2×
“1) ECG Data: To search for the most appropriate thresholds, we used 73 different records from four Physionet [41] databases: 1) European ST–T database [45]; 2) MIT-BIH Normal Sinus Rhythm database [46]; 3) MIT–BIH Arrhythmia database [47]; and 4) QT database [48].”
BackgroundMethodThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242 · cited 1×
“There are many good techniques to detect these fiducial points, in this paper, we use the techniques presented in [42] and [43] that are based on differentiation.”
MethodECG analysis: a new approach in human identification
Biel, L., Pettersson, O., Philipson, L., & Wide, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.930458 · Cited by 949
Israel, S. A., Irvine, J. M., Cheng, A., Wiederhold, M. D., & Wiederhold, B. K. (2005) · Pattern Recognition · doi:10.1016/j.patcog.2004.05.014 · Cited by 669 · cited 7×
“Different heuristic studies show that changes in the heart rate are linear [9], [11].”
BackgroundMethodInfluentialLaguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606 · cited 2×
“1) ECG Data: To search for the most appropriate thresholds, we used 73 different records from four Physionet [41] databases: 1) European ST–T database [45]; 2) MIT-BIH Normal Sinus Rhythm database [46]; 3) MIT–BIH Arrhythmia database [47]; and 4) QT database [48].”
BackgroundMethodIdentification of Humans Using Gait
Kale, A., Sundaresan, A., Rajagopalan, A. N., Cuntoor, N. P., Roy-Chowdhury, A. K., Kruger, V., & Chellappa, R. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.832865 · Cited by 566 · cited 1×
“, signature [23], voice [24], gait [25], or keystroke pattern [26]) characteristic that is measurable and present in everybody and that has unique differences that will not change significantly over time.”
BackgroundTADDEI, A., DISTANTE, G., EMDIN, M., PISANI, P., MOODY, G. B., ZEELENBERG, C., & MARCHESI, C. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060332 · Cited by 436
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413 · cited 1×
“[44] have shown that fiducial point detection methods based on differentiation are computationally more efficient than their counterpart.”
BackgroundAn introduction evaluating biometric systems
Phillips, P. J., Martin, A., Wilson, C. L., & Przybocki, M. (2000) · Computer · doi:10.1109/2.820040 · Cited by 391 · cited 2×
“But fingerprint authentication can fail if the fingerprint is damaged [4] or,”
Background
Cited by
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Security and Privacy for 6G: A Survey on Prospective Technologies and Challenges
Nguyen, V.-L., Lin, P.-C., Cheng, B.-C., Hwang, R.-H., & Lin, Y.-D. (2021) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3108618 · Cited by 515
“gram) and heart (electrocardiogram) signals have recently also emerged [187], [188].”
BackgroundA Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications
Wu, T., Wu, F., Qiu, C., Redoute, J.-M., & Yuce, M. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977164 · Cited by 224
“in the proposed sensor patch, the biometric ECG authentication can be a potential method for privacy protection in the future [30].”
MethodFerrag, M. A., Maglaras, L., Derhab, A., & Janicke, H. (2020) · Telecommunication Systems · doi:10.1007/s11235-019-00612-5 · Cited by 71
Metadata
- Authors
- Arteaga-Falconi, J. S., Al Osman, H., & El Saddik, A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2016-03
- Volume
- 65
- Issue
- 3
- Pages
- 591-600
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2268339064
- Cited by
- 200
- References
- 41
- FWCI
- 18.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.