ECG Authentication for Mobile Devices
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Traditional mobile login methods, like numerical or graphical passwords, are vulnerable to passive attacks. It is common for intruders to gain access to personal information of their victims by watching them enter their passwords into their mobile screens from a close proximity. With this in mind, a mobile biometric authentication algorithm based on electrocardiogram (ECG) is proposed. With this algorithm, the user will only need to touch two ECG electrodes (lead I) of the mobile device to gain access. The algorithm was tested with a cell phone case heart monitor in a controlled laboratory experiment at different times and conditions with ten subjects and also with 73 records obtained from the Physionet database. The obtained results reveal that our algorithm has 1.41% false acceptance rate and 81.82% true acceptance rate with 4 s of signal acquisition. To the best of our knowledge, this is the first approach on mobile authentication that uses ECG biometric signals and it shows a promising future for this technology. Nonetheless, further improvements are still needed to optimize accuracy while maintaining a short acquisition time for authentication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812 · cited 2×
“1) ECG Data: To search for the most appropriate thresholds, we used 73 different records from four Physionet [41] databases: 1) European ST–T database [45]; 2) MIT-BIH Normal Sinus Rhythm database [46]; 3) MIT–BIH Arrhythmia database [47]; and 4) QT database [48].”
BackgroundMethodThe principles of software QRS detection
Kohler, B.-U., Hennig, C., & Orglmeister, R. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.993193 · Cited by 1,242 · cited 1×
“There are many good techniques to detect these fiducial points, in this paper, we use the techniques presented in [42] and [43] that are based on differentiation.”
MethodECG analysis: a new approach in human identification
Biel, L., Pettersson, O., Philipson, L., & Wide, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.930458 · Cited by 949
Israel, S. A., Irvine, J. M., Cheng, A., Wiederhold, M. D., & Wiederhold, B. K. (2005) · Pattern Recognition · doi:10.1016/j.patcog.2004.05.014 · Cited by 669 · cited 7×
“Different heuristic studies show that changes in the heart rate are linear [9], [11].”
BackgroundMethodInfluentialLaguna, P., Mark, R. G., Goldberg, A., & Moody, G. B. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.648140 · Cited by 606 · cited 2×
“1) ECG Data: To search for the most appropriate thresholds, we used 73 different records from four Physionet [41] databases: 1) European ST–T database [45]; 2) MIT-BIH Normal Sinus Rhythm database [46]; 3) MIT–BIH Arrhythmia database [47]; and 4) QT database [48].”
BackgroundMethodIdentification of Humans Using Gait
Kale, A., Sundaresan, A., Rajagopalan, A. N., Cuntoor, N. P., Roy-Chowdhury, A. K., Kruger, V., & Chellappa, R. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.832865 · Cited by 566 · cited 1×
“, signature [23], voice [24], gait [25], or keystroke pattern [26]) characteristic that is measurable and present in everybody and that has unique differences that will not change significantly over time.”
BackgroundTADDEI, A., DISTANTE, G., EMDIN, M., PISANI, P., MOODY, G. B., ZEELENBERG, C., & MARCHESI, C. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060332 · Cited by 436
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413 · cited 1×
“[44] have shown that fiducial point detection methods based on differentiation are computationally more efficient than their counterpart.”
BackgroundAn introduction evaluating biometric systems
Phillips, P. J., Martin, A., Wilson, C. L., & Przybocki, M. (2000) · Computer · doi:10.1109/2.820040 · Cited by 391 · cited 2×
“But fingerprint authentication can fail if the fingerprint is damaged [4] or,”
BackgroundA practical guide to biometric security technology
Liu, S., & Silverman, M. (2001) · IT Professional · doi:10.1109/6294.899930 · Cited by 379 · cited 1×
“, signature [23], voice [24], gait [25], or keystroke pattern [26]) characteristic that is measurable and present in everybody and that has unique differences that will not change significantly over time.”
BackgroundPerformance evaluation of fingerprint verification systems
Cappelli, R., Maio, D., Maltoni, D., Wayman, J. L., & Jain, A. K. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.20 · Cited by 372
Van Alste, J. A., & Schilder, T. S. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325514 · Cited by 367
Wavelet Distance Measure for Person Identification Using Electrocardiograms
Chan, A. D. C., Hamdy, M. M., Badre, A., & Badee, V. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.909996 · Cited by 363
BiolD: a multimodal biometric identification system
Frischholz, R. W., & Dieckmann, U. (2000) · Computer · doi:10.1109/2.820041 · Cited by 346
Unobtrusive User-Authentication on Mobile Phones Using Biometric Gait Recognition
Derawi, M. O., Nickel, C., Bours, P., & Busch, C. (2010) · 2010 Sixth International Conference on Intelligent Information Hiding and Multimedia Signal Processing · doi:10.1109/iihmsp.2010.83 · Cited by 343 · cited 3×
“[32] suggest that validation rates are promising but are not reliable enough for practical use yet.”
BackgroundMethodKrishan, K., Kanchan, T., & Bumbrah, G. S. (2012) · Journal of Forensic and Legal Medicine · doi:10.1016/j.jflm.2011.12.018 · Cited by 286 · cited 1×
“been used for over 100 years [3] in different applications,”
MethodOne-lead ECG for identity verification
Shen, T. W., Tompkins, W. J., & Hu, Y. H. (2003) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1134388 · Cited by 278
Clinical Electrocardiography: A Simplified Approach
(2006) · Elsevier eBooks · doi:10.1016/b0-323-04038-1/x5001-x · Cited by 273
Geometrical aspects of the interindividual variability of multilead ECG recordings
Hoekema, R., Uijen, G. J. H., & van Oosterom, A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.918594 · Cited by 252
Verification of humans using the electrocardiogram
Wübbeler, G., Stavridis, M., Kreiseler, D., Bousseljot, R.-D., & Elster, C. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.01.014 · Cited by 231 · cited 4×
“[12] performed ECG verification based on”
BackgroundMethodInfluentialDRAPER, H. W., PEFFER, C. J., STALLMANN, F. W., LITTMANN, D., & PIPBERGER, H. V. (1964) · Circulation · doi:10.1161/01.cir.30.6.853 · Cited by 225
Image-Quality-Based Adaptive Face Recognition
Sellahewa, H., & Jassim, S. A. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2037989 · Cited by 188 · cited 1×
“, face [20], eyes [21], fingerprints-palm [22], or ECG [9]) or behavioral (e.”
BackgroundPigment Melanin: Pattern for Iris Recognition
Hosseini, M. S., Araabi, B. N., & Hamid Soltanian-zadeh, A. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2037996 · Cited by 139 · cited 1×
“, face [20], eyes [21], fingerprints-palm [22], or ECG [9]) or behavioral (e.”
BackgroundMultimodal Biometric Person Authentication : A Review
Sahoo, S. K., Choubisa, T., & Prasanna, S. R. M. (2012) · IETE Technical Review · doi:10.4103/0256-4602.93139 · Cited by 104
Evaluation of Electrocardiogram for Biometric Authentication
Singh, Y. N., & Singh, S. (2012) · Journal of Information Security · doi:10.4236/jis.2012.31005 · Cited by 102 · cited 6×
“used in other works such as [9], [11], [12], [16], and [17];”
BackgroundMethodInfluentialAn ECG Classifier Designed Using Modified Decision Based Neural Networks
Simon, B. P., & Eswaran, C. (1997) · Computers and Biomedical Research · doi:10.1006/cbmr.1997.1446 · Cited by 97
Liu, J., Yu, F. R., Lung, C., & Tang, H. (2009) · IEEE Transactions on Wireless Communications · doi:10.1109/twc.2009.071036 · Cited by 97
Geometrical factors affecting the interindividual variability of the ECG and the VCG
van Oosterom, A., Hoekema, R., & Uijen, G. J. H. (2000) · Journal of Electrocardiology · doi:10.1054/jelc.2000.20356 · Cited by 95 · cited 1×
“conclude that ECG can be used as a biometric technique [38].”
MethodSaevanee, H., & Bhatarakosol, P. (2008) · International Conference on Computer and Electrical Engineering · doi:10.1109/iccee.2008.157 · Cited by 87
Pupil and Iris Localization for Iris Recognition in Mobile Phones
Cho, D.-H., Park, K. R., Rhee, D. W., Kim, Y., & Yang, J. (2006) · ACIS International Conference on Software Engineering, Artificial Intelligence, Networking and Parallel/Distributed Computing (SNPD) · doi:10.1109/snpd-sawn.2006.58 · Cited by 87 · cited 1×
“Existing approaches in biometric mobile access use the iris [29], voice [30], face [31], gesture [1], gait [32], or the fusion of different biometrics (e.”
BackgroundIntegrating Analytic and Appearance Attributes for Human Identification from ECG Signals
Wang, Y., Plataniotis, K. N., & Hatzinakos, D. (2006) · Biometrics Symposium · doi:10.1109/bcc.2006.4341627 · Cited by 83 · cited 2×
“Current ECG authentication algorithms, such as the ones proposed in [8]–[18], show good results in validating users.”
BackgroundMethodContactless palmprint and knuckle biometrics for mobile devices
Choraś, M., & Kozik, R. (2011) · Pattern Analysis and Applications · doi:10.1007/s10044-011-0248-4 · Cited by 72
Polynomial distance measurement for ECG based biometric authentication
Sufi, F. K., Khalil, I., & Habib, I. (2008) · Security and Communication Networks · doi:10.1002/sec.76 · Cited by 61
Engineering Gesture-Based Authentication Systems
Clark, G. D., & Lindqvist, J. (2015) · IEEE Pervasive Computing · doi:10.1109/mprv.2015.6 · Cited by 51
Medical biometrics: The perils of ignoring time dependency
Agrafioti, F., Bui, F. M., & Hatzinakos, D. (2009) · IEEE International Conference on Biometrics: Theory, Applications and Systems (BTAS) · doi:10.1109/btas.2009.5339042 · Cited by 39 · cited 1×
“According to [19], biometrics is any human physiological”
BackgroundToward Force-Based Signature Verification: A Pen-Type Sensor and Preliminary Validation
Wang, D., Zhang, Y., Yao, C., Wu, J., Jiao, H., & Liu, M. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2037871 · Cited by 38 · cited 1×
“, signature [23], voice [24], gait [25], or keystroke pattern [26]) characteristic that is measurable and present in everybody and that has unique differences that will not change significantly over time.”
BackgroundScotti, F., & Piuri, V. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2030866 · Cited by 30 · cited 1×
“Iris biometric authentication is a reliable technology but depends heavily on the acquisition of good quality images with appropriate lightning condition [34].”
BackgroundWang, S., & Liu, J. (2011) · InTech eBooks · doi:10.5772/17151 · Cited by 29 · cited 1×
“The mobile access method through voice recognition is susceptible to environmental noise or can be tricked by audio records [35].”
MethodIdentifying Individuals Using Eigenbeat Features of Electrocardiogram
Singh, Y. N., & Singh, S. K. (2013) · Journal of Engineering · doi:10.1155/2013/539284 · Cited by 23 · cited 6×
“used in other works such as [9], [11], [12], [16], and [17];”
BackgroundMethodInfluentialDiscrete Finger and Palmar Feature Extraction for Personal Authentication
Doi, J., & Yamanaka, M. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2005.858820 · Cited by 22 · cited 1×
“, face [20], eyes [21], fingerprints-palm [22], or ECG [9]) or behavioral (e.”
Background
Cited by
Kaplan Berkaya, S., Uysal, A. K., Sora Gunal, E., Ergin, S., Gunal, S., & Gulmezoglu, M. B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.03.003 · Cited by 610
Security and Privacy for 6G: A Survey on Prospective Technologies and Challenges
Nguyen, V.-L., Lin, P.-C., Cheng, B.-C., Hwang, R.-H., & Lin, Y.-D. (2021) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3108618 · Cited by 515
“gram) and heart (electrocardiogram) signals have recently also emerged [187], [188].”
BackgroundA Review of Signal Processing Techniques for Electrocardiogram Signal Quality Assessment
Satija, U., Ramkumar, B., & Manikandan, M. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2810957 · Cited by 295
A Rigid-Flex Wearable Health Monitoring Sensor Patch for IoT-Connected Healthcare Applications
Wu, T., Wu, F., Qiu, C., Redoute, J.-M., & Yuce, M. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977164 · Cited by 224
“in the proposed sensor patch, the biometric ECG authentication can be a potential method for privacy protection in the future [30].”
MethodFerrag, M. A., Maglaras, L., Derhab, A., & Janicke, H. (2020) · Telecommunication Systems · doi:10.1007/s11235-019-00612-5 · Cited by 71
Metadata
- Authors
- Arteaga-Falconi, J. S., Al Osman, H., & El Saddik, A.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2016-03
- Volume
- 65
- Issue
- 3
- Pages
- 591-600
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2268339064
- Cited by
- 200
- References
- 41
- FWCI
- 18.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.