The DOI matches its Crossref record.
Inductor Modeling in Wireless Links for Implantable Electronics
Abstract
This paper describes the ac power dissipation of coils as well as their self-capacitance, self-resonant frequency, and quality factor Q. In the past, self-resonant frequency was rarely calculated during design because of the lack of suitable closed-form design equations. However, coils are widely used in biomedical applications as inductive links for both power and data, and the power transfer capacity and the data rate of inductive links are determined by the operating frequency of the coils. The maximum operating frequency is limited by the self-resonant frequency of the coil. We present here an analytical express for the optimal frequency of a coil in terms of the design parameters. By varying the design parameters, we can move the optimal frequency close to the operating frequency, thereby boosting the efficiency of the inductive link. We have verified the derivation experimentally and shown it to be useful in optimizing coil Index performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
RamRakhyani, A. K., Mirabbasi, S., & Chiao, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2072782 · Cited by 945
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“Another approach is to calculate iteratively the AC resistance of WWC using [65]:”
BackgroundXue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“So far, these coils have been fabricated with thin wires by using sophisticated winding machinery [5].”
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227914 · Cited by 146
A Power and Data Link for a Wireless-Implanted Neural Recording System
Rush, A. D., & Troyk, P. R. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2214385 · Cited by 90
Metadata
- Authors
- Yang, Z., Liu, W., & Basham, E.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2007-10
- Volume
- 43
- Issue
- 10
- Pages
- 3851-3860
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2141805427
- Cited by
- 199
- References
- 0
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.