High-Speed Spiral-Scan Echo Planar NMR Imaging-I
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
An improved echo planar high-speed imaging technique using spiral scan is presented and experimental advantages are discussed. This proposed spiral-scan echo planar imaging (SEPI) technique employs two linearly increasing sinusoidal gradient fields, which results in a spiral trajectory in the spatial frequency domain (k-domain) that covers the entire frequency domain uniformly. The advantages of the method are: 1) circularly symmetric T2 weighting, resulting in a circularly symmetric point spread function in the image domain; 2) elimination of discontinuities in gradient waveforms which in turn will reduce initial transient as well as steady-state distortions; and 3) effective rapid spiral-scan from dc to high frequency in a continuous fashion, which ensures multiple pulsing with interlacing for further resolution improvement without T2 decay image degradation. Some preliminary experimental results will be presented and further possible improvements suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Mansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Cited by
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
Pipe, J. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l · Cited by 928
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Activation of the prefrontal cortex in a nonspatial working memory task with functional MRI
Cohen, J. D., Forman, S. D., Braver, T. S., Casey, B. J., Servan‐Schreiber, D., & Noll, D. C. (1994) · Human Brain Mapping · doi:10.1002/hbm.460010407 · Cited by 576
Self‐navigated spiral fMRI: Interleaved versus single‐shot
Glover, G. H., & Lai, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390305 · Cited by 476
Real‐time MRI at a resolution of 20 ms
Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1585 · Cited by 434
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Sampling density compensation in MRI: Rationale and an iterative numerical solution
Pipe, J. G., & Menon, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<179::aid-mrm25>3.0.co;2-v · Cited by 350
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
Single-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
Spiral K‐space MR imaging of cortical activation
Noll, D. C., Cohen, J. D., Meyer, C. H., & Schneider, W. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050112 · Cited by 254
Accelerating advanced MRI reconstructions on GPUs
Stone, S. S., Haldar, J. P., Tsao, S. C., Hwu, W.-M. W., Sutton, B. P., & Liang, Z.-P. (2008) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2008.05.013 · Cited by 249
High contrast and fast three‐dimensional magnetic resonance imaging at high fields
Lee, J., Garwood, M., Menon, R., Adriany, G., Andersen, P., Truwit, C. L., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340305 · Cited by 225
Compliance-Based Robotic Peg-in-Hole Assembly Strategy Without Force Feedback
Park, H., Park, J., Lee, D.-H., Park, J.-H., Baeg, M.-H., & Bae, J.-H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2682002 · Cited by 200
“The rubbing motion was drawn by using an Archimedes spiral, which has been proposed as the optimal scan trajectory [28], [29].”
MethodForbes, K. P. N., Pipe, J. G., Bird, C. R., & Heiserman, J. E. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1176 · Cited by 159
“Its motion correction benefits extend beyond those of projection-reconstruction (7) or spiral MRI (8,9) by offering targeted correction for the major in-plane head movements of rotation and translation.”
BackgroundLinear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
A CUDA-based reverse gridding algorithm for MR reconstruction
Yang, J., Feng, C., & Zhao, D. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.038 · Cited by 16
“Although EPI can finish sampling in less than 1 s [14,15] and use fast Fourier transform (FFT) to reconstruct images directly [16–18], it requires a professional gradient system.”
Method
Metadata
- Authors
- Ahn, C. B., Kim, J. H., & Cho, Z. H.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1986-03
- Volume
- 5
- Issue
- 1
- Pages
- 2-7
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2044823858
- Cited by
- 487
- References
- 4
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.