The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
What is the best similarity measure for motion correction in fMRI time series?
Abstract
It has been shown that the difference of squares cost function used by standard realignment packages (SPM and AIR) can lead to the detection of spurious activations, because the motion parameter estimations are biased by the activated areas. Therefore, this paper describes several experiments aiming at selecting a better similarity measure to drive functional magnetic resonance image registration. The behaviors of the Geman-McClure (GM) estimator, of the correlation ratio, and of the mutual information (MI) relative to activated areas are studied using simulated time series and actual data stemming from a 3T magnet. It is shown that these methods are more robust than the usual difference of squares measure. The results suggest also that the measures built from robust metrics like the GM estimator may be the best choice, while MI is also an interesting solution. Some more work, however, is required to compare the various robust metrics proposed in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Modeling Geometric Deformations in EPI Time Series
Andersson, J. L. R., Hutton, C., Ashburner, J., Turner, R., & Friston, K. (2001) · NeuroImage · doi:10.1006/nimg.2001.0746 · Cited by 1,011
B-spline signal processing. I. Theory
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193220 · Cited by 940
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
B-spline signal processing. II. Efficiency design and applications
Unser, M., Aldroubi, A., & Eden, M. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193221 · Cited by 641
Robust regression methods for computer vision: A review
Meer, P., Mintz, D., Rosenfeld, A., & Kim, D. Y. (1991) · International Journal of Computer Vision · doi:10.1007/bf00127126 · Cited by 638
B-SPLINE SIGNAL PROCESSING: PART I-THEORY
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 626
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
The correlation ratio as a new similarity measure for multimodal image registration
Roche, A., Malandain, G., Pennec, X., & Ayache, N. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056301 · Cited by 542
Self-citationArtifacts due to stimulus correlated motion in functional imaging of the brain
Hajnal, J. V., Myers, R., Oatridge, A., Schwieso, J. E., Young, I. R., & Bydder, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310307 · Cited by 486
B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS
Unser, M. A., Aldroubi, A., & Eden, M. (1993) · Cited by 463
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
Turner, R., Jezzard, P., Wen, H., Kwong, K. K., Le Bihan, D., Zeffiro, T., & Balaban, R. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290221 · Cited by 457
Hajnal, J. V., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/978-3-032-25169-5 · Cited by 402
Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
Freire, L., & Mangin, J.-F. (2001) · NeuroImage · doi:10.1006/nimg.2001.0869 · Cited by 308
Self-citationVoxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Interpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Motion detection and correction in functional MR imaging
Jiang, A., Kennedy, D. N., Baker, J. R., Weisskoff, R. M., Tootell, R. B. H., Woods, R. P., Benson, R. R., Kwong, K. K., Brady, T. J., Rosen, B. R., et al. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030306 · Cited by 195
Characterization and Correction of Interpolation Effects in the Realignment of fMRI Time Series
Grootoonk, S., Hutton, C., Ashburner, J., Howseman, A., Josephs, O., Rees, G. E., Friston, K. J., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.1999.0515 · Cited by 127
Fast Nonsupervised 3D Registration of PET and MR Images of the Brain
Mangin, J., Frouin, V., Isabelle Bloch, A., Bendriem, B., & López-Krahe, J. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.96 · Cited by 96
Self-citationWu, D. H., Lewin, J. S., & Duerk, J. L. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070219 · Cited by 94
Nikou, C., Heitz, F., Armspach, J., Namer, I. J., & Grucker, D. (1998) · NeuroImage · doi:10.1006/nimg.1998.0335 · Cited by 63
Generalized Correlation Ratio for Rigid Registration of 3D Ultrasound with MR Images
Roche, A., Xavier Pennec, B., Rudolph, M., Auer, D. P., Malandain, G., Sebastien Ourselin, A., Auer, L. M., & Ayache, N. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_58 · Cited by 58
Self-citationXiong (1999) · doi:10.1002/(sici)1097-0193(1999)8:2/3
Cited by
Aberrant “Default Mode” Functional Connectivity in Schizophrenia
Garrity, A. G., Pearlson, G. D., McKiernan, K., Lloyd, D., Kiehl, K. A., & Calhoun, V. D. (2007) · American Journal of Psychiatry · doi:10.1176/ajp.2007.164.3.450 · Cited by 1,114
Estimating the number of independent components for functional magnetic resonance imaging data
Li, Y., Adalı, T., & Calhoun, V. D. (2007) · Human Brain Mapping · doi:10.1002/hbm.20359 · Cited by 912
Widespread reward-system activation in obese women in response to pictures of high-calorie foods
Stoeckel, L. E., Weller, R. E., Cook, E. W., Twieg, D. B., Knowlton, R. C., & Cox, J. E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.02.031 · Cited by 857
Sakoğlu, Ü., Pearlson, G. D., Kiehl, K. A., Wang, Y. M., Michael, A. M., & Calhoun, V. D. (2010) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-010-0197-8 · Cited by 620
Deep learning for neuroimaging: a validation study
Plis, S. M., Hjelm, D. R., Salakhutdinov, R., Allen, E. A., Bockholt, H. J., Long, J. D., Johnson, H. J., Paulsen, J. S., Turner, J. A., & Calhoun, V. D. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00229 · Cited by 586
Metadata
- Authors
- Freire, L., Roche, A., & Mangin, J.-F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 470-484
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2136763679
- Cited by
- 353
- References
- 38
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.