ORBIT: A Multiresolution Framework for Deformable Registration of Brain Tumor Images
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A deformable registration method is proposed for registering a normal brain atlas with images of brain tumor patients. The registration is facilitated by first simulating the tumor mass effect in the normal atlas in order to create an atlas image that is as similar as possible to the patient's image. An optimization framework is used to optimize the location of tumor seed as well as other parameters of the tumor growth model, based on the pattern of deformation around the tumor region. In particular, the optimization is implemented in a multiresolution and hierarchical scheme, and it is accelerated by using a principal component analysis (PCA)-based model of tumor growth and mass effect, trained on a computationally more expensive biomechanical model. Validation on simulated and real images shows that the proposed registration framework, referred to as ORBIT (optimization of tumor parameters and registration of brain images with tumors), outperforms other available registration methods particularly for the regions close to the tumor, and it has the potential to assist in constructing statistical atlases from tumor-diseased brain images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
A new point matching algorithm for non-rigid registration
Chui, H., & Rangarajan, A. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00009-2 · Cited by 1,560
Growth patterns in the developing brain detected by using continuum mechanical tensor maps
Thompson, P. M., Giedd, J. N., Woods, R. P., MacDonald, D., Evans, A. C., & Toga, A. W. (2000) · Nature · doi:10.1038/35004593 · Cited by 850
Computer-assisted imaging to assess brain structure in healthy and diseased brains
Ashburner, J., Csernansk, J. G., Davatzikos, C., Fox, N. C., Frisoni, G. B., & Thompson, P. M. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00304-1 · Cited by 371
Self-citation
Cited by
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Zacharaki et al. [195], [196] also trained a statistical model based on simulations of the tumor effect [185].”
BackgroundSelf-citationA survey of MRI-based medical image analysis for brain tumor studies
Bauer, S., Wiest, R., Nolte, L.-P., & Reyes, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/r97 · Cited by 1,036
A review of atlas-based segmentation for magnetic resonance brain images
Cabezas, M., Oliver, A., Lladó, X., Freixenet, J., & Bach Cuadra, M. (2011) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.07.015 · Cited by 416
DRAMMS: Deformable registration via attribute matching and mutual-saliency weighting
Ou, Y., Sotiras, A., Paragios, N., & Davatzikos, C. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.07.002 · Cited by 407
Self-citationZhu, X., Suk, H.-I., & Shen, D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.078 · Cited by 202
“Next, we used HAMMER(4) [37] (although other methods [21, 32, 39, 38, 52, 54] can be used) to conduct registration and obtained the Region-Of-Interest (ROI)-labeled image based on the Jacob template, which dissects a brain into 93 ROIs [23].”
Self-citationA Generative Model for Brain Tumor Segmentation in Multi-Modal Images
Menze, B. H., van Leemput, K., Lashkari, D., Weber, M.-A., Ayache, N., & Golland, P. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15745-5_19 · Cited by 201
“Tumors may be modeled as outliers relative to the expected shape [4,5] or image signal of healthy tissues [2,6].”
Background
Metadata
- Authors
- Zacharaki, E. I., Shen, D., Lee, S.-K., & Davatzikos, C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-08
- Volume
- 27
- Issue
- 8
- Pages
- 1003-1017
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2150410007
- Cited by
- 107
- References
- 5
- FWCI
- 15.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.