The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Robust Super-Resolution Volume Reconstruction From Slice Acquisitions: Application to Fetal Brain MRI
Open accessAbstract
Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acquired by these techniques, inter-slice motion leads to severe motion artifacts that are apparent in out-of-plane views. Slice sequential acquisitions do not enable 3-D volume representation. In this study, we have developed a novel technique based on a slice acquisition model, which enables the reconstruction of a volumetric image from multiple-scan slice acquisitions. The super-resolution volume reconstruction is formulated as an inverse problem of finding the underlying structure generating the acquired slices. We have developed a robust M-estimation solution which minimizes a robust error norm function between the model-generated slices and the acquired slices. The accuracy and robustness of this novel technique has been quantitatively assessed through simulations with digital brain phantom images as well as high-resolution newborn images. We also report here successful application of our new technique for the reconstruction of volumetric fetal brain MRI from clinically acquired data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stochastic relaxation, gibbs distributions, and the bayesian restoration of images.
Geman, S., & Geman, D. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767596 · Cited by 17,949
Robust Statistics: The Approach Based on Influence Functions
Ruppert, D. (1987) · Technometrics · doi:10.2307/1269782 · Cited by 3,880
Numerical Recipes 3rd Edition: The Art of Scientific Computing
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (2007) · Cambridge University Press eBooks · Cited by 3,328
Super-resolution image reconstruction: a technical overview
Park, S. C., Park, M. K., & Kang, M. G. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1203207 · Cited by 3,282
Numerical methods for least squares problems
(1996) · Choice Reviews Online · doi:10.5860/choice.34-1602 · Cited by 3,007
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Brain injury in premature infants: a complex amalgam of destructive and developmental disturbances
Volpe, J. J. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70294-1 · Cited by 2,410
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Fast and Robust Multiframe Super Resolution
Farsiu, S., Robinson, M. D., Elad, M., & Milanfar, P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.834669 · Cited by 2,090
Understanding robust and exploratory data analysis
Hoaglin, D. C., Mosteller, F. C., & Tukey, J. W. (1983) · Wiley eBooks · Cited by 1,906
Cited by
Super-resolution: a comprehensive survey
Nasrollahi, K., & Moeslund, T. B. (2014) · Machine Vision and Applications · doi:10.1007/s00138-014-0623-4 · Cited by 684
Reconstruction of fetal brain MRI with intensity matching and complete outlier removal
Kuklisova-Murgasova, M., Quaghebeur, G., Rutherford, M. A., Hajnal, J. V., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.07.004 · Cited by 426
Gholipour, A., Rollins, C. K., Velasco-Annis, C., Ouaalam, A., Akhondi-Asl, A., Afacan, O., Ortinau, C. M., Clancy, S., Limperopoulos, C., Yang, E., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00525-w · Cited by 363
Self-citationDelayed cortical development in fetuses with complex congenital heart disease
Clouchoux, C., du Plessis, A. J., Bouyssi-Kobar, M., Tworetzky, W., McElhinney, D. B., Brown, D. W., Gholipour, A., Kudelski, D., Warfield, S. K., McCarter, R. J., et al. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs281 · Cited by 309
Self-citationEbner, M., Wang, G., Li, W., Aertsen, M., Patel, P. A., Aughwane, R., Melbourne, A., Doel, T., Dymarkowski, S., De Coppi, P., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116324 · Cited by 288
Plenge, E., Poot, D. H. J., Bernsen, M., Kotek, G., Houston, G., Wielopolski, P., van der Weerd, L., Niessen, W. J., & Meijering, E. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24187 · Cited by 271
Super‐resolution in magnetic resonance imaging: A review
Van Reeth, E., Tham, I. W. K., Tan, C. H., & Poh, C. L. (2012) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.21249 · Cited by 269
Delineation of early brain development from fetuses to infants with diffusion MRI and beyond
Ouyang, M., Dubois, J., Yu, Q., Mukherjee, P., & Huang, H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.017 · Cited by 258
Fast Volume Reconstruction From Motion Corrupted Stacks of 2D Slices
Kainz, B., Steinberger, M., Wein, W., Kuklisova-Murgasova, M., Malamateniou, C., Keraudren, K., Torsney-Weir, T., Rutherford, M., Aljabar, P., Hajnal, J. V., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2415453 · Cited by 200
Computational Health Informatics in the Big Data Age: A Survey
Fang, R., Pouyanfar, S., Yang, Y., Chen, S.-C., & Iyengar, S. S. (2017) · ACM Computing Surveys · doi:10.1145/2932707 · Cited by 210
Quantitative in vivo MRI measurement of cortical development in the fetus
Clouchoux, C., Kudelski, D., Gholipour, A., Warfield, S. K., Viseur, S., Bouyssi-Kobar, M., Mari, J.-L., Evans, A. C., du Plessis, A. J., & Limperopoulos, C. (2012) · Brain Structure and Function · doi:10.1007/s00429-011-0325-x · Cited by 164
“Ultrafast T2-weighted MR images provide good contrast between the different developing cerebral tissues, however, combined fetal and maternal motion during data acquisition results in image degradation (Jiang et al. 2007; Rousseau et al. 2006; Clouchoux et al. 2010b; Gholipour et al. 2010a).”
BackgroundMethodInfluentialSelf-citationAutomatic quantification of normal cortical folding patterns from fetal brain MRI
Wright, R., Kyriakopoulou, V., Ledig, C., Rutherford, M. A., Hajnal, J. V., Rueckert, D., & Aljabar, P. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.01.034 · Cited by 134
Real-time Deep Pose Estimation with Geodesic Loss for Image-to-Template Rigid Registration
Salehi, S. S. M., Khan, S., Erdogmus, D., & Gholipour, A. (2018) · arXiv · doi:10.48550/arxiv.1803.05982 · Cited by 118
“Prior work on slice-to-volume registration in fetal MRI has shown a strong need for regularization and initialization of slice transformations through hierarchical registration [22],”
BackgroundMethodSelf-citationLearning-based prediction of gestational age from ultrasound images of the fetal brain
Namburete, A. I. L., Stebbing, R. V., Kemp, B., Yaqub, M., Papageorghiou, A. T., & Alison Noble, J. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.12.006 · Cited by 97
“, 2006), and super-resolution techniques (Gholipour et al., 2010; Kim et al., 2010; Rousseau et al., 2010), 3D MR images with high signal-to-noise ratio and improved spatial resolution are now available and have stimulated studies of fetal (Caldairou et al.”
BackgroundMethodAutomated fetal brain segmentation from 2D MRI slices for motion correction
Keraudren, K., Kuklisova-Murgasova, M., Kyriakopoulou, V., Malamateniou, C., Rutherford, M. A., Kainz, B., Hajnal, J. V., & Rueckert, D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.023 · Cited by 91
“The most common approach is slice-to-volume registration, where slices are iteratively registered to an estimation of the reconstructed 3D volume (Rousseau et al., 2006; Jiang et al., 2007; Gholipour et al., 2010; Kuklisova-Murgasova et al., 2012).”
Wang, G., Zuluaga, M. A., Pratt, R., Aertsen, M., Doel, T., Klusmann, M., David, A. L., Deprest, J., Vercauteren, T., & Ourselin, S. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.009 · Cited by 73
Predicting Slice-to-Volume Transformation in Presence of Arbitrary Subject Motion
Hou, B., Alansary, A., McDonagh, S., Davidson, A., Rutherford, M., Hajnal, J. V., Rueckert, D., Glocker, B., & Kainz, B. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8_34 · Cited by 68
“that involves slice-wise re-alignment of randomly displaced anatomy [4,8,14,11].”
BackgroundLearning to map 2D ultrasound images into 3D space with minimal human annotation
Yeung, P.-H., Aliasi, M., Papageorghiou, A. T., Haak, M., Xie, W., & Namburete, A. I. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101998 · Cited by 55
Mapping fetal brain development based on automated segmentation and 4D brain atlasing
Li, H., Yan, G., Luo, W., Liu, T., Wang, Y., Liu, R., Zheng, W., Zhang, Y., Li, K., Zhao, L., et al. (2021) · Brain Structure and Function · doi:10.1007/s00429-021-02303-x · Cited by 41
“2015) of 2D multi-slice images with the super-resolution (SR) technique (Gholipour et al. 2010; Kuklisova-Murgasova et al. 2012; Rousseau et al. 2010) is commonly used to achieve the 3D volumetric reconstruction of the fetal brains.”
MethodScattered slice shard reconstruction for motion correction in multi-shell diffusion MRI
Christiaens, D., Cordero-Grande, L., Pietsch, M., Hutter, J., Price, A. N., Hughes, E. J., Vecchiato, K., Deprez, M., Edwards, A. D., Hajnal, J. V., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117437 · Cited by 4
Metadata
- Authors
- Gholipour, A., Estroff, J. A., & Warfield, S. K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-10
- Volume
- 29
- Issue
- 10
- Pages
- 1739-1758
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2135264048
- Cited by
- 360
- References
- 40
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.