Real-Time Regularized Ultrasound Elastography
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
This paper introduces two real-time elastography techniques based on analytic minimization (AM) of regularized cost functions. The first method (1D AM) produces axial strain and integer lateral displacement, while the second method (2D AM) produces both axial and lateral strains. The cost functions incorporate similarity of radio-frequency (RF) data intensity and displacement continuity, making both AM methods robust to small decorrelations present throughout the image. We also exploit techniques from robust statistics to make the methods resistant to large local decorrelations. We further introduce Kalman filtering for calculating the strain field from the displacement field given by the AM methods. Simulation and phantom experiments show that both methods generate strain images with high SNR, CNR and resolution. Both methods work for strains as high as 10% and run in real-time. We also present in vivo patient trials of ablation monitoring. An implementation of the 2D AM method as well as phantom and clinical RF-data can be downloaded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Kalman Filter
Welch, G., & Bishop, G. (1995) · CiteSeer X (The Pennsylvania State University) · Cited by 7,039
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Lucas-Kanade 20 Years On: A Unifying Framework
Baker, S., & Matthews, I. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000011205.11775.fd · Cited by 3,155 · cited 1×
“It is shown in [47] that the two techniques converge to the same results.”
ResultRobust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115 · cited 19×
“1D AM, wo IRLS 2D AM, wo IRLS (a) Unbiased reg.”
BackgroundMethodInfluentialBoone, K. G., & Holder, D. S. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02520003 · Cited by 1,919
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703 · cited 1×
“ratio is set to in both phantoms to mimic real tissue [56], [57] which causes the phantoms to deform in and directions as a result of the compression in the direction.”
BackgroundStatistics of Speckle in Ultrasound B-Scans
Wagner, R. F., Smith, S. W., Sandrik, J. M., & Lopez, H. (1983) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1983.31404 · Cited by 1,398 · cited 1×
“4 × 10(5) scatterers with Gaussian scattering strengths [50] are uniformly distributed in the first a d second phantom, ensuring more than 10 scatterers [51] exist in a resolution cell.”
BackgroundEfficient region tracking with parametric models of geometry and illumination
Hager, G. D., & Belhumeur, P. N. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.722606 · Cited by 1,066 · cited 4×
“Among many proposed shapes for w(·), we compared the performance of Huber [40], [39]”
BackgroundResultInfluentialSelf-citationUsing dynamic programming for solving variational problems in vision
Amini, A. A., Weymouth, T. E., & Jain, R. C. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.57681 · Cited by 1,008 · cited 1×
“DP is an efficient method for global optimization and has been used extensively in many applications in computer vision including solving for optimal deformable models [42].”
MethodInternal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Selected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671 · cited 1×
“Most elastography techniques estimate local displacement s of tissue based on amplitude correlation [15], [16] or phase correlation of the radio-frequency (RF) echoes [17], [18].”
BackgroundImaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514 · cited 1×
“Among many variations of ultrasound elastography [1]–[4], our work focuses on real-time static elastography, a well-known technique that applies quasi-static compression of tissue and simultaneously images it with ultrasound.”
BackgroundA fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479 · cited 1×
“Assuming a stationary signal model for the RF data, the use of large correlation windows helps to reduce jitter erro rs (variance) for all motion field estimation techniques studi ed in [15], [19].”
MethodKonofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444 · cited 2×
“Lateral strain1 estimation is obtained in [28] by iteratively calculating axial strain, companding RF data and interpola ting in the lateral direction.”
BackgroundMethodA novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Bohs, L. N., & Trahey, G. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133210 · Cited by 438 · cited 1×
“Initially, 2D motion estimation started in the field of blood flow estimation using speckle tracking [25].”
MethodUltrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412 · cited 1×
“Lateral strain contains important information from tissue structure that is not available from axial strain [31], [46], [47].”
BackgroundShum, H.-Y., & Szeliski, R. (2000) · International Journal of Computer Vision · doi:10.1023/a:1008195814169 · Cited by 412
In vivo real-time freehand palpation imaging
Hall, T. J., Zhu, Y., & Spalding, C. S. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00733-0 · Cited by 394 · cited 2×
“vessels due to blood motion, 3) extremely low correlation in lesions that contain liquid due to the incoherent fluid motion [17], [8], and 4) out-of-plane motion of movable structures within the image [17].”
BackgroundConstruction of Panoramic Image Mosaics with Global and Local Alignment
Shum, H.-Y., & Szeliski, R. (2001) · Monographs in Computer Science · doi:10.1007/978-1-4757-3482-9_13 · Cited by 356
Pesavento, A., Perrey, C., Krueger, M., & Ermert, H. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.796111 · Cited by 296 · cited 1×
“Most elastography techniques estimate local displacement s of tissue based on amplitude correlation [15], [16] or phase correlation of the radio-frequency (RF) echoes [17], [18].”
BackgroundMyocardial elastography—a feasibility study in vivo
Konofagou, E. E., D’hooge, J., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00488-x · Cited by 264
A comparison of the performance of time-delay estimators in medical ultrasound
Viola, F., & Walker, W. F. (2003) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1197962 · Cited by 233 · cited 3×
“Therefore, in addition to reducing the spatial resolution [23], larger windows result in significant signal decorrelation [24], [23], [18].”
Background2-D companding for noise reduction in strain imaging
Chaturvedi, P., Insana, M. F., & Hall, T. J. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.646923 · Cited by 231
Ultrasound Elastography Based on Multiscale Estimations of Regularized Displacement Fields
Pellot-Barakat, C. J. M., Frouin, F., Insana, M. F., & Herment, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.822825 · Cited by 183 · cited 1×
“[32] proposed minimizing a regulariz ed energy function that combines constraints of conservation of echo amplitude and displacement continuity.”
BackgroundQuantitative elasticity imaging: what can and cannot be inferred from strain images
Barbone, P. E., & Bamber, J. C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/310 · Cited by 171 · cited 1×
“reconstruct the strain tensor), Poi ss n’s ratio and Young’s modulus [23], [24].”
BackgroundDoyley, M. M., Bamber, J. C., Fuechsel, F. G., & Bush, N. L. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00429-x · Cited by 169 · cited 1×
“Real-time elastography is of key importance in many diagnosis applications [11], [6], [12], [8], [13] and in guidance/monitoring of surgical operations [14]–[16].”
BackgroundVarghese, T., Zagzebski, J. A., & Lee, F. T. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00656-7 · Cited by 169
Multilevel and Motion Model-Based Ultrasonic Speckle Tracking Algorithms
Yeung, F., Levinson, S. F., & Parker, K. J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00281-0 · Cited by 159 · cited 2×
“Therefore, in addition to reducing the spatial resolution [20], larger windows result in significant signal de correlation [21], [20], [15].”
BackgroundMethodNoninvasive Vascular Elastography: Theoretical Framework
Maurice, R. L., Ohayon, J., Fretigny, Y., Bertrand, M., Soulez, G., & Cloutier, G. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823066 · Cited by 158 · cited 1×
“In another work [29], tissue defor mation is modeled by locally affine transformations to obtai n both lateral and axial strains.”
BackgroundUltrasound Elastography: A Dynamic Programming Approach
Rivaz, H. J., Boctor, E. M., Foroughi, P., et al. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.917243 · Cited by 153 · cited 5×
“timization procedure [40], but it only gives integer displacements.”
BackgroundMethodInfluentialSelf-citationA unified view of imaging the elastic properties of tissue
Parker, K. J., Taylor, L. S., Gracewski, S. M., & Rubens, D. J. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1880772 · Cited by 142 · cited 1×
“Among many variations of ultrasound elastography [1]–[4], our work focuses on real-time static elastography, a well-known technique that applies quasi-static compression of tissue and simultaneously images it with ultrasound.”
BackgroundLateral speckle tracking using synthetic lateral phase
Chen, X., Zohdy, M. J., Emelianov, S., et al. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320827 · Cited by 110 · cited 1×
“Incorporation of the synthetic lateral phase [57], [58], [59] into 2D AM to further improve the accuracy of the lateral displacement measurement is also a subject of future work.”
BackgroundLorenz, A., Sommerfeld, H. J., Garcia-Schürmann, M., Philippou, S., Senge, T., & Ermert, H. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.796120 · Cited by 99 · cited 1×
“Real-time elastography is of key importance i n many diagnosis applications [8], [3], [9], [5], [10] and in guidance/monitoring of surgical operations [11], [12], [1 3].”
BackgroundA new approach to elastography using mutual information and finite elements
Miga, M. I. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/4/304 · Cited by 91 · cited 1×
“Another work [67] has utilized the solution of the elasticity reconstruction to improve motion estimation in an iterative framework.”
MethodIdentifying the mechanical properties of tissue by ultrasound strain imaging
Turgay, E., Salcudean, S. E., & Rohling, R. N. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.09.015 · Cited by 87 · cited 1×
“It requires no extra hardware, provides ease of use and has attracted increasing interest in recent years [2], [3], [4], [5], [6], [7].”
BackgroundBrusseau, É., Kybic, J., Deprez, J.-F., & Basset, O. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.897408 · Cited by 77 · cited 2×
“In another work [33], both signal shift and scale are found through minimization of a regularized cost function.”
BackgroundResultA quality-guided displacement tracking algorithm for ultrasonic elasticity imaging
Chen, L., Treece, G. M., Lindop, J. E., et al. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.10.007 · Cited by 75 · cited 1×
“This is, in principle, similar to guiding the displacement estimation based on a data quality indicator [48].”
Background3D elastography using freehand ultrasound
Lindop, J. E., Treece, G. M., Gee, A. H., et al. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.11.018 · Cited by 69
Normal and shear strain estimation using beam steering on linear-array transducers
Rao, M., Chen, Q., Shi, H., Varghese, T., Madsen, E. L., Zagzebski, J. A., & Wilson, T. A. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.027 · Cited by 54 · cited 1×
“Beam steering has been used to solve this issu e [27].”
MethodJiang, J., Varghese, T., Brace, C. L., Madsen, E. L., Hall, T. J., Bharat, S., Hobson, M. A., Zagzebski, J. A., & Lee, F. T. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015355 · Cited by 54 · cited 1×
“Recent work [65] has attempted to reconstruct elasticity from the displacement field for monitoring thermal ablation.”
BackgroundAblation Monitoring with Elastography: 2D In-vivo and 3D Ex-vivo Studies
Rivaz, H. J., Fleming, I. N., Assumpcao, L., Gabor Fichtinger, A., Hamper, U. M., Choti, M. A., Hager, G. D., & Boctor, E. M. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_55 · Cited by 51 · cited 1×
“Some preliminary results are published in [15].”
Self-citationSumi, C. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561622 · Cited by 49 · cited 1×
“A 2D displacement field is required to calculate the thermal expansion, lateral and shea r strain fields [22] (i.”
Performance analysis of steady-state harmonic elastography
Doyley, M. M., Feng, Q., Weaver, J. B., & Paulsen, K. D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/002 · Cited by 12 · cited 1×
“The spatial resolution of the reconstructed images is determined with a three-step approach [5 5], [56]; first, the edge spread function is computed by averagin g the pixel values across the background-inclusion interfac (the li e in Figure 10 (a)); second, the line spread function (LSF ) is computed by differentiatin…”
MethodUniform precision ultrasound strain imaging
Treece, G. M., Lindop, J. E., Gee, A., et al. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1330 · Cited by 10 · cited 1×
“In a recent work [39], a displacement field is first calculated by minimizing phase differences in correlation windows [21].”
MethodTracked Ultrasound Elastography (TrUE)
Foroughi, P., Rivaz, H. J., Fleming, I. N., et al. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15745-5_2 · Cited by 5 · cited 1×
“Having a fast algorithm, like 2D AM, makes it plausible to invest time to perform real-time frame selection, an area that we are currently working on [16], [64].”
MethodSelf-citation
Metadata
- Authors
- Rivaz, H., Boctor, E. M., Choti, M. A., & Hager, G. D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-04
- Volume
- 30
- Issue
- 4
- Pages
- 928-945
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2131986555
- Cited by
- 177
- References
- 46
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.