Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
We introduce a novel algorithm to reconstruct dynamic magnetic resonance imaging (MRI) data from under-sampled k-t space data. In contrast to classical model based cine MRI schemes that rely on the sparsity or banded structure in Fourier space, we use the compact representation of the data in the Karhunen Louve transform (KLT) domain to exploit the correlations in the dataset. The use of the data-dependent KL transform makes our approach ideally suited to a range of dynamic imaging problems, even when the motion is not periodic. In comparison to current KLT-based methods that rely on a two-step approach to first estimate the basis functions and then use it for reconstruction, we pose the problem as a spectrally regularized matrix recovery problem. By simultaneously determining the temporal basis functions and its spatial weights from the entire measured data, the proposed scheme is capable of providing high quality reconstructions at a range of accelerations. In addition to using the compact representation in the KLT domain, we also exploit the sparsity of the data to further improve the recovery rate. Validations using numerical phantoms and in vivo cardiac perfusion MRI data demonstrate the significant improvement in performance offered by the proposed scheme over existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(2006) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/978-0-387-40065-5 · Cited by 9,008
Model Selection and Estimation in Regression with Grouped Variables
Yuan, M., & Lin, Y. (2006) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2005.00532.x · Cited by 7,261 · cited 1×
“We do not promote joint sparsity as done in [19].”
A Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809
Exact Matrix Completion via Convex Optimization
Candès, E. J., & Recht, B. (2009) · Foundations of Computational Mathematics · doi:10.1007/s10208-009-9045-5 · Cited by 4,877
Enhancing Sparsity by Reweighted ℓ 1 Minimization
Candès, E. J., Wakin, M. B., & Boyd, S. P. (2008) · Journal of Fourier Analysis and Applications · doi:10.1007/s00041-008-9045-x · Cited by 4,863
Guaranteed Minimum-Rank Solutions of Linear Matrix Equations via Nuclear Norm Minimization
Recht, B., Fazel, M., & Parrilo, P. A. (2010) · SIAM Review · doi:10.1137/070697835 · Cited by 3,471
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975 · cited 3×
“proofs in [24], it can be shown that the three-step scheme converges to the global minimum of for any fixed .”
Sparse signal reconstruction from limited data using FOCUSS: a re-weighted minimum norm algorithm
Gorodnitsky, I. F., & Rao, B. D. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.558475 · Cited by 1,834
Image recovery via total variation minimization and related problems
Chambolle, A., & Lions, P.-L. (1997) · Numerische Mathematik · doi:10.1007/s002110050258 · Cited by 1,569
Cited by
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
“el.unser@epfl.ch). November 14, 2016 DRAFT arXiv:1611.03679v1 [cs.CV] 11 Nov 2016 2 have been particularly influential in the field of biomedical imaging, e.g., in magnetic resonance imaging (MRI) [10], [11] and X-ray computed tomography (CT) [12], [13]. These devices face an unfavorable trade-off between noise and acqui…”
BackgroundA deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
Self-citationDemene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Accelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Convolutional Recurrent Neural Networks for Dynamic MR Image Reconstruction
Qin, C., Schlemper, J., Caballero, J., Price, A. N., Hajnal, J. V., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2863670 · Cited by 603
Deep Generative Adversarial Neural Networks for Compressive Sensing MRI
Mardani, M., Gong, E., Cheng, J. Y., Vasanawala, S. S., Zaharchuk, G., Xing, L., & Pauly, J. M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2858752 · Cited by 552
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
Qu, X., Hou, Y., Lam, F., Guo, D., Zhong, J., & Chen, Z. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.007 · Cited by 340
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
AMP-Net: Denoising-Based Deep Unfolding for Compressive Image Sensing
Zhang, Z., Liu, Y., Liu, J., Wen, F., & Zhu, C. (2021) · IEEE Transactions on Image Processing · doi:10.1109/tip.2020.3044472 · Cited by 311
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Image Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Jin, K. H., Lee, D., & Ye, J. C. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2601296 · Cited by 245
“Accurate MRI reconstruction from less data makes compressed sensing a hot topic in the research community; thus, it has been applied across many different application areas such as in pediatric imaging [6], dynamic cardiac MRI [7]–[9], perfusion imaging [10], angiography [11], and so on.”
Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candes, E. J., Sing-Long, C. A., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 243
Compressed sensing MRI: a review from signal processing perspective
Ye, J. C. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0006-z · Cited by 208
Fast Multiclass Dictionaries Learning With Geometrical Directions in MRI Reconstruction
Zhan, Z., Cai, J.-F., Guo, D., Liu, Y., Chen, Z., & Qu, X. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2503756 · Cited by 202
“, parallel imaging [4]–[9], non-Cartesian sampling [10]–[12], low rank [13]–[15], and nonconvex optimization [16]–[19], can further speed up imaging.”
BackgroundImproved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling
Zhao, B., Setsompop, K., Adalsteinsson, E., Gagoski, B., Ye, H., Ma, D., Jiang, Y., Ellen Grant, P., Griswold, M. A., & Wald, L. L. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26701 · Cited by 179
“This is different from (5,19) in which the low-rank constraint is enforced implicitly via a surrogate function (e.g., the nuclear norm (22)).”
BackgroundMR Image Reconstruction Using Deep Density Priors
Tezcan, K. C., Baumgartner, C. F., Luechinger, R., Pruessmann, K. P., & Konukoglu, E. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2887072 · Cited by 167
“The random undersam-pling approach was primarily motivated by the compressed sensing framework [3], [4], [5], [6], [7], where the incoherence between k-space sampling and some sparsifying transform was exploited.”
MethodDirect parametric reconstruction from undersampled (k,t)-space data in dynamic contrast enhanced MRI
Dikaios, N., Arridge, S., Hamy, V., Punwani, S., & Atkinson, D. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.05.001 · Cited by 40
Wang, N., Gaddam, S., Wang, L., Xie, Y., Fan, Z., Yang, W., Tuli, R., Lo, S., Hendifar, A., Pandol, S., et al. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28167 · Cited by 21
Metadata
- Authors
- Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2011-05
- Volume
- 30
- Issue
- 5
- Pages
- 1042-1054
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2156739854
- Cited by
- 664
- References
- 32
- FWCI
- 23.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.