The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Image reconstruction from highly undersampled (k,t)-space data with joint partial separability and sparsity constraints
Open accessAbstract
Partial separability (PS) and sparsity have been previously used to enable reconstruction of dynamic images from undersampled (k,t)-space data. This paper presents a new method to use PS and sparsity constraints jointly for enhanced performance in this context. The proposed method combines the complementary advantages of PS and sparsity constraints using a unified formulation, achieving significantly better reconstruction performance than using either of these constraints individually. A globally convergent computational algorithm is described to efficiently solve the underlying optimization problem. Reconstruction results from simulated and in vivo cardiac MRI data are also shown to illustrate the performance of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Decoding by Linear Programming
Candes, E. J., & Tao, T. (2005) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.858979 · Cited by 7,121
Trefethen, L. N., & Bau, III (1997) · doi:10.1137/1.9780898719574 · Cited by 3,301
Weik, M. H. (2000) · Computer Science and Communications Dictionary · doi:10.1007/1-4020-0613-6_12436 · Cited by 2,570
Computational Methods for Inverse Problems
Vogel, C. R. (2002) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898717570 · Cited by 2,370
A New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975 · cited 6×
“6 [42]): Let be a submatrix of whose entries are taken from”
BackgroundMethodInfluentialBregman Iterative Algorithms for $\ell_1$-Minimization with Applications to Compressed Sensing
Yin, W., Osher, S., Goldfarb, D., & Darbon, J. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/070703983 · Cited by 1,414
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277
Alternating Direction Algorithms for $\ell_1$-Problems in Compressive Sensing
Yang, J., & Zhang, Y. (2011) · SIAM Journal on Scientific Computing · doi:10.1137/090777761 · Cited by 1,201
Computational Methods for Sparse Solution of Linear Inverse Problems
Tropp, J. A., & Wright, S. J. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2044010 · Cited by 1,046
Nonlinear image recovery with half-quadratic regularization
Geman, D., & Yang, C. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.392335 · Cited by 1,000
NESTA: A Fast and Accurate First-Order Method for Sparse Recovery
Becker, S., Bobin, J., & Candès, E. J. (2009) · Cited by 897
NESTA: A Fast and Accurate First-Order Method for Sparse Recovery
Becker, S., Bobin, J., & Candès, E. J. (2011) · SIAM Journal on Imaging Sciences · doi:10.1137/090756855 · Cited by 848
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Compressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Analysis of Half-Quadratic Minimization Methods for Signal and Image Recovery
Nikolova, M., & Ng, M. K. (2005) · SIAM Journal on Scientific Computing · doi:10.1137/030600862 · Cited by 478
Functional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
SPATIOTEMPORAL IMAGINGWITH PARTIALLY SEPARABLE FUNCTIONS
Liang, Z.-P. (2007) · 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2007.357020 · Cited by 369
Self-citationk-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
Lustig, M. S., Santos, J. M., Donoho, D. L., & Pauly, J. M. (2006) · Cited by 313
k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis
Pedersen, H., Kozerke, S., Ringgaard, S., Nehrke, K., & Kim, W. Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22052 · Cited by 294
ADMiRA: Atomic Decomposition for Minimum Rank Approximation
Lee, K., & Bresler, Y. (2010) · IEEE Transactions on Information Theory · doi:10.1109/tit.2010.2054251 · Cited by 267
Improved k–t BLAST and k–t SENSE using FOCUSS
Jung, H., Ye, J. C., & Kim, E. Y. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/11/018 · Cited by 250
Introduction to Functional Magnetic Resonance Imaging: Principles and Techniques
Buxton, R. B. (2002) · Cambridge University Press eBooks · doi:10.1017/cbo9780511549854 · Cited by 229
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Spatiotemporal Imaging with Partially Separable Functions
Liang, Z.-P. (2007) · 2007 Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging · doi:10.1109/nfsi-icfbi.2007.4387720 · Cited by 204
Self-citationRobust principal component analysis-based four-dimensional computed tomography
Gao, H., Cai, J.-F., Shen, Z., & Zhao, H. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/11/002 · Cited by 181
Analysis and compensation of eddy currents in balanced SSFP
Bieri, O., Markl, M., & Scheffler, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20527 · Cited by 156
Rank-Constrained Solutions to Linear Matrix Equations Using PowerFactorization
Haldar, J. P., & Hernando, D. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2018223 · Cited by 156
Self-citationAdluru, G., McGann, C. J., Speier, P., Kholmovski, E. G., Shaaban, A. M., & DiBella, E. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21585 · Cited by 155
k‐t group sparse: A method for accelerating dynamic MRI
Usman, M., Prieto, C., Schaeffter, T., & Batchelor, P. G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22883 · Cited by 92
A Finite Smoothing Algorithm for Linear $l_1 $ Estimation
Madsen, K., & Nielsen, H. B. (1993) · SIAM Journal on Optimization · doi:10.1137/0803010 · Cited by 88
Mistretta, C. A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21683 · Cited by 61
Modified compressive sensing for real-time dynamic MR imaging
Lu, W., & Vaswani, N. (2009) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2009.5414208 · Cited by 58
Sparse‐CAPR: Highly accelerated 4D CE‐MRA with parallel imaging and nonconvex compressive sensing
Trzasko, J. D., Haider, C. R., Borisch, E. A., Campeau, N. G., Glockner, J. F., Riederer, S. J., & Manduca, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22892 · Cited by 45
INTRODUCTION TO FUNCTIONAL MAGNETIC RESONANCE IMAGING: PRINCIPLES AND TECHNIQUES
Henson, R. N. (2003) · Brain · doi:10.1093/brain/awg251 · Cited by 39
Improved Time Series Reconstruction for Dynamic Magnetic Resonance Imaging
Sümbül, U., Santos, J. M., & Pauly, J. M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012030 · Cited by 37
Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI
Aggarwal, N., & Bresler, Y. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/4/045015 · Cited by 36
Brinegar, C., Schmitter, S. S., Mistry, N. N., Johnson, G. A., & Liang, Z. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22500 · Cited by 34
Self-citationLattice-theoretic analysis of time-sequential sampling of spatiotemporal signals. I
Willis, N. P., & Bresler, Y. (1997) · IEEE Transactions on Information Theory · doi:10.1109/18.567677 · Cited by 30
Zhao, B., Haldar, J. P., Christodoulou, A., & Liang, Z. (2011) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2011.5872707 · Cited by 15
Self-citation
Cited by
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Qu, X., Hou, Y., Lam, F., Guo, D., Zhong, J., & Chen, Z. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.09.007 · Cited by 340
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
Self-citationImage Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Metadata
- Authors
- Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-09
- Volume
- 31
- Issue
- 9
- Pages
- 1809-1820
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2008257035
- Cited by
- 295
- References
- 47
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.