MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-based discrete optimization strategies have been proposed to overcome problems involved with continuous optimization for registration, in particular its susceptibility to local minima. However, to date the simplifications made to obtain tractable computational complexity reduced the registration accuracy. We address these challenges and preserve the potentially higher quality of discrete approaches with three novel contributions. First, we use an image-derived minimum spanning tree as a simplified graph structure, which copes well with the complex sliding motion and allows us to find the global optimum very efficiently. Second, a stochastic sampling approach for the similarity cost between images is introduced within a symmetric, diffeomorphic B-spline transformation model with diffusion regularization. The complexity is reduced by orders of magnitude and enables the minimization of much larger label spaces. In addition to the geometric transform labels, hyper-labels are introduced, which represent local intensity variations in this task, and allow for the direct estimation of lung ventilation. We validate the improvements in accuracy and performance on exhale-inhale CT volume pairs using a large number of expert landmarks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Stochastic Approximation Method
Robbins, H., & Monro, S. (1951) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729586 · Cited by 9,643
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“tion with brain tissue segmentation in [36].”
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 1×
“level B-spline scheme [31], in which we only employ the highest resolution image.”
MethodAn experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Shortest Connection Networks And Some Generalizations
Prim, R. C. (1957) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1957.tb01515.x · Cited by 4,565
What energy functions can be minimized via graph cuts?
Kolmogorov, V., & Zabih, R. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1262177 · Cited by 3,127
Pictorial Structures for Object Recognition
Felzenszwalb, P. F., & Huttenlocher, D. P. (2005) · International Journal of Computer Vision · doi:10.1023/b:visi.0000042934.15159.49 · Cited by 2,180
Efficient Belief Propagation for Early Vision
Felzenszwalb, P. F., & Huttenlocher, D. P. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7899-4 · Cited by 1,345
Cited by
TransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Gibson, E., Giganti, F., Hu, Y., Bonmati, E., Bandula, S., Gurusamy, K., Davidson, B., Pereira, S. P., Clarkson, M. J., & Barratt, D. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806309 · Cited by 697
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
Unsupervised Learning of Probabilistic Diffeomorphic Registration for Images and Surfaces
Dalca, A. V., Balakrishnan, G., Guttag, J., & Sabuncu, M. R. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.07.006 · Cited by 467
“Common representations are displacement vector fields, including elastic-type models [8, 21, 62], free-form deformations with b-splines [61], statistical parametric mapping [6], Demons [56, 66], and more recently discrete methods [19, 30, 28].”
BackgroundEvaluation of algorithms for Multi-Modality Whole Heart Segmentation: An open-access grand challenge
Zhuang, X., Li, L., Payer, C., Štern, D., Urschler, M., Heinrich, M. P., Oster, J., Wang, C., Smedby, Ö., Bian, C., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101537 · Cited by 361
Evaluation of segmentation methods on head and neck CT: Auto‐segmentation challenge 2015
Raudaschl, P. F., Zaffino, P., Sharp, G. C., Spadea, M. F., Chen, A., Dawant, B. M., Albrecht, T., Gass, T., Langguth, C., Lüthi, M., et al. (2017) · Medical Physics · doi:10.1002/mp.12197 · Cited by 259
SynthMorph: Learning Contrast-Invariant Registration Without Acquired Images
Hoffmann, M., Billot, B., Greve, D. N., Iglesias, J. E., Fischl, B., & Dalca, A. V. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3116879 · Cited by 201
“run the deedsBCV [93] patch-similarity method, which we tune for neuroimaging.”
MethodTowards realtime multimodal fusion for image-guided interventions using self-similarities
Heinrich, M. P., Jenkinson, M., Papież, B. W., Brady, S. M., & Schnabel, J. A. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40811-3_24 · Cited by 176
Self-citationEvaluation of Six Registration Methods for the Human Abdomen on Clinically Acquired CT
Xu, Z., Lee, C. P., Heinrich, M. P., Modat, M., Rueckert, D., Ourselin, S., Abramson, R. G., & Landman, B. A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2574816 · Cited by 175
“We selected five registration tools that have been successful in volumetric brain registrations, including FMRIB Software Library (FSL) [9], Image Registration Toolkit (IRTK) [10], NiftyReg [11], Advanced Normalization Tools (ANTs) [12], and DEnsE Displacement Sampling (DEEDS) [13] due to their academic popularity and…”
MethodPulmonary CT Registration Through Supervised Learning With Convolutional Neural Networks
Eppenhof, K. A. J., & Pluim, J. P. W. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2878316 · Cited by 173
“The TRE values for our method, Elastix, and five methods from literature that also validate on the DIR-Lab data set ([28], [29], [30], [31], [32]) are shown Table II.”
Method
Metadata
- Authors
- Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-07
- Volume
- 32
- Issue
- 7
- Pages
- 1239-1248
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2016974693
- Cited by
- 311
- References
- 40
- FWCI
- 21.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.