The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Abstract
Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-based discrete optimization strategies have been proposed to overcome problems involved with continuous optimization for registration, in particular its susceptibility to local minima. However, to date the simplifications made to obtain tractable computational complexity reduced the registration accuracy. We address these challenges and preserve the potentially higher quality of discrete approaches with three novel contributions. First, we use an image-derived minimum spanning tree as a simplified graph structure, which copes well with the complex sliding motion and allows us to find the global optimum very efficiently. Second, a stochastic sampling approach for the similarity cost between images is introduced within a symmetric, diffeomorphic B-spline transformation model with diffusion regularization. The complexity is reduced by orders of magnitude and enables the minimization of much larger label spaces. In addition to the geometric transform labels, hyper-labels are introduced, which represent local intensity variations in this task, and allow for the direct estimation of lung ventilation. We validate the improvements in accuracy and performance on exhale-inhale CT volume pairs using a large number of expert landmarks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Stochastic Approximation Method
Robbins, H., & Monro, S. (1951) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729586 · Cited by 9,643
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507 · cited 1×
“tion with brain tissue segmentation in [36].”
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Shortest Connection Networks And Some Generalizations
Prim, R. C. (1957) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1957.tb01515.x · Cited by 4,565
What energy functions can be minimized via graph cuts?
Kolmogorov, V., & Zabih, R. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1262177 · Cited by 3,127
Pictorial Structures for Object Recognition
Felzenszwalb, P. F., & Huttenlocher, D. P. (2005) · International Journal of Computer Vision · doi:10.1023/b:visi.0000042934.15159.49 · Cited by 2,180
Efficient Belief Propagation for Early Vision
Felzenszwalb, P. F., & Huttenlocher, D. P. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7899-4 · Cited by 1,345
Large Displacement Optical Flow: Descriptor Matching in Variational Motion Estimation
Brox, T., & Malik, J. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.143 · Cited by 1,295
Convergent Tree-Reweighted Message Passing for Energy Minimization
Kolmogorov, V. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.200 · Cited by 1,095
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Self-citationCastillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
Self-citationA Log-Euclidean Framework for Statistics on Diffeomorphisms
Arsigny, V., Commowick, O., Pennec, X., & Ayache, N. (2006) · Lecture Notes in Computer Science · doi:10.1007/11866565_113 · Cited by 432
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Dense image registration through MRFs and efficient linear programming
Glocker, B., Komodakis, N., Tziritas, G., Navab, N., & Paragios, N. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.006 · Cited by 427
Intensity-Based Image Registration by Minimizing Residual Complexity
Myronenko, A., & Song, X. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053043 · Cited by 325
Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.007 · Cited by 322
Diffeomorphic Registration Using B-Splines
Rueckert, D., Aljabar, P., Heckemann, R. A., Hajnal, J. V., & Hammers, A. (2006) · Lecture Notes in Computer Science · doi:10.1007/11866763_86 · Cited by 315
Discrete-continuous optimization for large-scale structure from motion
Crandall, D., Owens, A., Snavely, N., & Huttenlocher, D. (2011) · CVPR 2011 · doi:10.1109/cvpr.2011.5995626 · Cited by 308
Stereo Correspondence by Dynamic Programming on a Tree
Veksler, O. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.334 · Cited by 295
Four-dimensional deformable image registration using trajectory modeling
Castillo, E., Castillo, R., Martinez, J., Shenoy, M., & Guerrero, T. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/018 · Cited by 261
(2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-23626-6 · Cited by 261
Metz, C. T., Klein, S., Schaap, M., van Walsum, T., & Niessen, W. J. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.10.003 · Cited by 236
Mass preserving nonrigid registration of CT lung images using cubic B‐spline
Yin, Y., Hoffman, E. A., & Lin, C. (2009) · Medical Physics · doi:10.1118/1.3193526 · Cited by 207
Atlas-driven lung lobe segmentation in volumetric X-ray CT images
Zhang, L., Hoffman, E. A., & Reinhardt, J. M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.859209 · Cited by 200
Fast, Approximately Optimal Solutions for Single and Dynamic MRFs
Komodakis, N., Tziritas, G., & Paragios, N. (2007) · 2007 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2007.383095 · Cited by 185
Phase mutual information as a similarity measure for registration
Mellor, M. P., & Brady, M. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.01.002 · Cited by 143
Self-citationA simple fixed‐point approach to invert a deformation fielda)
Chen, M., Lu, W., Chen, Q., Ruchala, K., & Olivera, G. (2007) · Medical Physics · doi:10.1118/1.2816107 · Cited by 101
Estimation of slipping organ motion by registration with direction-dependent regularization
Schmidt-Richberg, A., Werner, R., Heinz Handels, A., & Ehrhardt, J. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.06.007 · Cited by 99
Efficient MRF deformation model for non-rigid image matching
Shekhovtsov, A., Kovtun, I., & Hlaváč, V. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2008.06.006 · Cited by 92
Vandemeulebroucke, J., Bernard, O., Rit, S., Kybic, J., Clarysse, P., & Sarrut, D. (2012) · Medical Physics · doi:10.1118/1.3679009 · Cited by 87
Mass preserving image registration for lung CT
Gorbunova, V., Jon Sporring, A., Lo, P., Loeve, M., Tiddens, H. A. W. M., Nielsen, M., Dirksen, A., & de Bruijne, M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.11.001 · Cited by 81
Integrating Segmentation Information for Improved MRF-Based Elastic Image Registration
Mahapatra, D., & Sun, Y. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2162738 · Cited by 66
Heinrich, M. P., Jenkinson, M., Brady, S. M., et al. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33454-2_15 · Cited by 54
Self-citationNon-rigid image registration of brain magnetic resonance images using graph-cuts
So, R. W. K., Tang, T. W. H., & Chung, A. C. S. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2011.04.008 · Cited by 54
Discrete symmetric image registration
Sotiras, A., & Nikos Paragios, A. (2012) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2012.6235554 · Cited by 23
Deformable 3D Volume Registration Using Efficient MRFs Model with Decomposed Nodes
Lee, K. J., Kwon, D., Yun, I. D., & Lee, S. U. (2008) · British Machine Vision Conference (BMVC) · doi:10.5244/c.22.59 · Cited by 10
Cited by
TransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Gibson, E., Giganti, F., Hu, Y., Bonmati, E., Bandula, S., Gurusamy, K., Davidson, B., Pereira, S. P., Clarkson, M. J., & Barratt, D. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806309 · Cited by 697
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
Unsupervised Learning of Probabilistic Diffeomorphic Registration for Images and Surfaces
Dalca, A. V., Balakrishnan, G., Guttag, J., & Sabuncu, M. R. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.07.006 · Cited by 467
Evaluation of algorithms for Multi-Modality Whole Heart Segmentation: An open-access grand challenge
Zhuang, X., Li, L., Payer, C., Štern, D., Urschler, M., Heinrich, M. P., Oster, J., Wang, C., Smedby, Ö., Bian, C., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101537 · Cited by 361
Metadata
- Authors
- Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-07
- Volume
- 32
- Issue
- 7
- Pages
- 1239-1248
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2016974693
- Cited by
- 311
- References
- 40
- FWCI
- 21.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.