CoChat

Real-Time Deep Pose Estimation With Geodesic Loss for Image-to-Template Rigid Registration

Open access
Mohseni Salehi, Seyed Sadegh, Khan, Shadab, Erdogmus, Deniz, Gholipour, Ali · 2019 · IEEE Transactions on Medical Imaging
Cited by 115

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

With an aim to increase the capture range and accelerate the performance of state-of-the-art inter-subject and subject-to-template 3-D rigid registration, we propose deep learning-based methods that are trained to find the 3-D position of arbitrarily-oriented subjects or anatomy in a canonical space based on slices or volumes of medical images. For this, we propose regression convolutional neural networks (CNNs) that learn to predict the angle-axis representation of 3-D rotations and translations using image features. We use and compare mean square error and geodesic loss to train regression CNNs for 3-D pose estimation used in two different scenarios: slice-to-volume registration and volume-to-volume registration. As an exemplary application, we applied the proposed methods to register arbitrarily oriented reconstructed images of fetuses scanned in-utero at a wide gestational age range to a standard atlas space. Our results show that in such registration applications that are amendable to learning, the proposed deep learning methods with geodesic loss minimization achieved 3-D pose estimation with a wide capture range in real-time (<100ms). We also tested the generalization capability of the trained CNNs on an expanded age range and on images of newborn subjects with similar and different MR image contrasts. We trained our models on T2-weighted fetal brain MRI scans and used them to predict the 3-D pose of newborn brains based on T1-weighted MRI scans. We showed that the trained models generalized well for the new domain when we performed image contrast transfer through a conditional generative adversarial network. This indicates that the domain of application of the trained deep regression CNNs can be further expanded to image modalities and contrasts other than those used in training. A combination of our proposed methods with accelerated optimization-based registration algorithms can dramatically enhance the performance of automatic imaging devices and image processing methods of the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2018.2866442

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Research works printed but not linked: 30

  1. 10.1088/0031-9155/46/3/201 · DOI · Paper page
  2. 10.1109/TMI.2003.815867 · DOI · Paper page
  3. 10.1109/TMI.2007.892508 · DOI · Paper page
  4. 10.1016/j.media.2017.04.010 · DOI · Paper page
  5. 10.1109/CVPR.2015.7298965 · DOI · Paper page
  6. 10.1109/TMI.2016.2553401 · DOI · Paper page
  7. 10.1007/978-3-319-46726-9_2 · DOI · Paper page
  8. 10.1109/TBME.2015.2496253 · DOI · Paper page
  9. 10.1007/978-3-319-46466-4_22 · DOI
  10. 10.1109/ICRA.2017.7989233 · DOI · Paper page
  11. 10.1109/CVPR.2015.7298758 · DOI · Paper page
  12. 10.1109/ICCV.2015.308 · DOI · Paper page
  13. 10.1109/ICCVW.2017.254 · doi:10.1109/iccvw.2017.254 · Paper page
  14. 10.1007/s10851-009-0161-2 · DOI · Paper page
  15. 10.1109/TMI.2010.2051680 · DOI · Paper page
  16. 10.1016/j.neuroimage.2017.04.033 · DOI · Paper page
  17. 10.1109/TMI.2018.2798801 · DOI · Paper page
  18. 10.1016/j.media.2018.02.006 · DOI · Paper page
  19. 10.1002/cmr.a.21321 · DOI · Paper page
  20. 10.1002/1522-2594(200009)44:3<457::AID-MRM17>3.0.CO;2-R · DOI · Paper page
  21. 10.1002/mrm.22176 · DOI · Paper page
  22. 10.1109/IEMBS.2011.6091385 · DOI
  23. 10.1109/TMI.2016.2555244 · DOI
  24. 10.1007/978-3-319-67564-0_8 · DOI
  25. 10.1109/ISBI.2018.8363675 · DOI
  26. 10.1109/TMI.2017.2721362 · DOI · Paper page
  27. 10.1038/s41598-017-00525-w · DOI · Paper page
  28. Arvo, 2013, Graphics Gems II
  29. 10.1109/CVPR.2017.632 · DOI · Paper page
  30. 10.1109/ICCV.2017.244 · DOI · Paper page

Cited by

See all 115

Metadata

Authors
Mohseni Salehi, S. S., Khan, S., Erdogmus, D., & Gholipour, A.
Venue
IEEE Transactions on Medical Imaging
Published
2019-02
Volume
38
Issue
2
Pages
470-481
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2805701966
Cited by
115
References
16
FWCI
3.99
Type
journal article
Language
en
Open access
green
Funders
  • McKnight Foundation
  • National Institute of Biomedical Imaging and Bioengineering (R01 EB018988)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Deep Pose Estimation With Geodesic Loss for Image-to-Template Rigid Registration. https://app.cochat.ai/papers/10.1109/tmi.2018.2866442
The paper
Mohseni Salehi, S. S., Khan, S., Erdogmus, D., & Gholipour, A. (2019). Real-Time Deep Pose Estimation With Geodesic Loss for Image-to-Template Rigid Registration. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2018.2866442

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.