A Classification Approach Based on Directed Acyclic Graph to Predict Locomotion Activities With One Inertial Sensor on the Thigh
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Current state-of-the-art locomotion mode classifiers for controlling robotic lower-limb prostheses rely on multiple sensors to achieve high accuracy, prediction performance, and robustness to both speed changes and subject-specific gait patterns. However, multiple sensors placed on different body parts usually entail discomfort and poor usability for the user. This paper presents an intention detection method that relies on the features extracted from an inertial measurement unit worn on the thigh and an online phase estimator. The algorithm classifies the locomotion mode of the upcoming stride among the three modes of ground-level walking, stair ascent, and stair descent. A two-stage classification process first distinguishes between transient and steady-state strides and then classifies the locomotion mode of the impending stride based on directed acyclic graphs of binary classifiers. The classification is performed at 75% or 85% of the previous stride phase, respectively for steady-state and transient strides. Data were gathered from 10 healthy subjects and processed offline. Feature design and selection were based on the data of all subjects, while the classification performance was assessed by leave-one-subject-out cross-validation. Results presented a median recognition accuracy of 98.7% for steady-state strides and 95.6% for transitions, suggesting that the method was inherently robust to variations in gait cadence, since all of the features were phase-based and not dependent on fixed time intervals. These results inform the design of control strategies for active transfemoral prostheses able to predict the user’s locomotion intention during the next stride, using minimum sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Inertial sensors can accurately capture dynamic parameters such as body acceleration and angular velocity, but in gait monitoring, robustness to changes in speed and step frequency is particularly important 124 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [124]
In the citing paper
“It is difficult for them to distinguish between the stance and swing phases during the gait cycle and they lack sensitivity to pathological gait behaviors such as those seen in Parkinson's disease.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [124]
In the citing paper
“In the studies of Chen et al. 129 and Papapicco et al. 124 , the recognition accuracy of steadystate stride length exceeded 98.0%.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [124]
In the citing paper
“| IMU and pressure sensitive insoles | Gait recognition | 3 | 98.7% | 124 |”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [124]
Citations
Cites
Applied Linear Statistical Models.
Barnett, V., Neter, J., & Wasserman, W. (1975) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2984653 · Cited by 2,286
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Large Margin DAG's for Multiclass Classification
Platt, J. C., Cristianini, N., & Shawe-Taylor, J. S. (1999) · ePrints Soton (University of Southampton) · Cited by 1,889
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 4×
“Several intention detection methods have been developed to address this challenge, following approaches that range from simple rule-based algorithms to more complex neural networks [2], [3], [6]–[10].”
BackgroundMethodInfluentialAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
Redfern, M. S., Cham, R., Gielo-Perczak, K., Grönqvist, R., Hirvonen, M., Lanshammar, H., Marpet, M., Pai, C. Y.-C., & Powers, C. (2001) · Ergonomics · doi:10.1080/00140130110085547 · Cited by 385
Gait dynamics on an inclined walkway
McIntosh, A. S., Beatty, K. T., Dwan, L. N., & Vickers, D. R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.025 · Cited by 384
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225640 · Cited by 206
Volitional Control of a Prosthetic Knee Using Surface Electromyography
Ha, K. H., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2070840 · Cited by 205
Stair Ascent With a Powered Transfemoral Prosthesis Under Direct Myoelectric Control
Hoover, C. D., Fulk, G. D., & Fite, K. B. (2012) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2012.2200498 · Cited by 159
A Training Method for Locomotion Mode Prediction Using Powered Lower Limb Prostheses
Young, A. J., Simon, A. M., & Hargrove, L. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2285101 · Cited by 150
An oscillator-based smooth real-time estimate of gait phase for wearable robotics
Yan, T., Parri, A., Garate, V. R., Cempini, M., Ronsse, R., & Vitiello, N. (2016) · Autonomous Robots · doi:10.1007/s10514-016-9566-0 · Cited by 146
Self-citationYoung, A. J., & Hargrove, L. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412461 · Cited by 142
Online Phase Detection Using Wearable Sensors for Walking with a Robotic Prosthesis
Goršič, M., Kamnik, R., Ambrožič, L., Vitiello, N., Lefeber, D., Pasquini, G., & Munih, M. (2014) · Sensors · doi:10.3390/s140202776 · Cited by 121
Self-citationPressure-Sensitive Insoles for Real-Time Gait-Related Applications
Martini, E., Fiumalbi, T., Dell’Agnello, F., Ivanić, Z., Munih, M., Vitiello, N., & Crea, S. (2020) · Sensors · doi:10.3390/s20051448 · Cited by 107
Self-citationMartinez-Hernandez, U., & Dehghani-Sanij, A. A. (2018) · Neural Networks · doi:10.1016/j.neunet.2018.02.017 · Cited by 97
Speed-Adaptation Mechanism: Robotic Prostheses Can Actively Regulate Joint Torque
Lenzi, T., Hargrove, L., & Sensinger, J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360305 · Cited by 92
A Phase Variable Approach for IMU-Based Locomotion Activity Recognition
Bartlett, H. L., & Goldfarb, M. T. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2750139 · Cited by 89
Non-weight-bearing neural control of a powered transfemoral prosthesis
Hargrove, L. J., Simon, A. M., Lipschutz, R., Finucane, S. B., & Kuiken, T. A. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-62 · Cited by 73
The Design and Initial Experimental Validation of an Active Myoelectric Transfemoral Prosthesis
Hoover, C. D., Fulk, G. D., & Fite, K. B. (2012) · Journal of Medical Devices · doi:10.1115/1.4005784 · Cited by 67
Sikder, F., & Sarkar, D. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2707921 · Cited by 38
Human activity recognition using inertial measurement units and smart shoes
Chinimilli, P. T., Redkar, S., & Zhang, W. (2017) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2017.7963159 · Cited by 35
ExoProsthetics: Assisting Above-Knee Amputees with a Lightweight Powered Hip Exoskeleton
Ishmael, M. K., Tran, M., & Lenzi, T. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779412 · Cited by 29
Simon, A. M., Fey, N. P., Ingraham, K. A., Young, A. J., & Hargrove, L. J. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696148 · Cited by 28
A Two-Dimensional Feature Space-Based Approach for Human Locomotion Recognition
Chinimilli, P. T., Redkar, S., & Sugar, T. G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2895289 · Cited by 27
Real-time gait event recognition for wearable assistive device using an IMU on thigh
Piriyakulkit, S., Hirata, Y., & Ozawa, H. (2017) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2017.8266123 · Cited by 15
Slope Estimation during Normal Walking Using a Shank-Mounted Inertial Sensor
López, A. M., Álvarez, D., González, R. C., & Alvarez, J. C. (2012) · Sensors · doi:10.3390/s120911910 · Cited by 11
Papapicco, V., Parri, A., Martini, E., Bevilacqua, V., Crea, S., & Vitiello, N. (2018) · Springer proceedings in advanced robotics · doi:10.1007/978-3-319-89327-3_15 · Cited by 3
Self-citationA Preliminary Study on Locomotion Mode Recognition with Wearable Sensors
Chen, B., Papapicco, V., Parri, A., Crea, S., Munih, M., & Vitiello, N. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_130 · Cited by 2
Self-citation
Research works printed but not linked: 1
- platt, 2000, Large margin DAGs for multiclass classification, Proc 12th Int Conf Neural Inf Process Syst, 547
Cited by
Bruinsma, J., & Carloni, R. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3086843 · Cited by 49
Bian, Q., Castellani, M., Shepherd, D. E. T., Duan, J., & Ding, Z. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3365201 · Cited by 23
Feng, Y., Xue, D., Ju, L., Zhang, W., & Ding, X. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3202658 · Cited by 12
A multimodal framework based on deep belief network for human locomotion intent prediction
Li, J., Zhang, J., Li, K., Cao, J., & Li, H. (2024) · Biomedical Engineering Letters · doi:10.1007/s13534-024-00351-w · Cited by 11
A Sports Digital Training System Based on Middle and Bottom Visual Information
Luo, L. (2022) · Mobile Information Systems · doi:10.1155/2022/6765954 · Cited by 10
Metadata
- Authors
- Papapicco, V., Chen, B., Munih, M., Davalli, A., Sacchetti, R., Gruppioni, E., Crea, S., & Vitiello, N.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Tianjin University (CN)
- University of Ljubljana (SI)
- Istituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro (IT)
- Venue
- IEEE Transactions on Medical Robotics and Bionics
- Published
- 2021-05
- Volume
- 3
- Issue
- 2
- Pages
- 436-445
- ISSN
- 2576-3202 (ISSN-L)
- OpenAlex
- W3158857539
- Cited by
- 19
- References
- 32
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 1 · 2022: 3 · 2021: 3
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Medical Robotics and Bionics (publishedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- Istituto Nazionale per l’Assicurazione contro gli Infortuni sul Lavoro (PPR-AI 1/2 MOTU)
- Joint Ethics Committee of Scuola Superiore Sant’Anna (9)
- Declaration of Helsinki
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- directed acyclic graphs, inertial measurement unit, lower limb prosthesis, gait phase estimation, binary classifier ensembles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.