A Training Method for Locomotion Mode Prediction Using Powered Lower Limb Prostheses
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Recently developed lower-limb prostheses are capable of actuating the knee and ankle joints, allowing amputees to perform advanced locomotion modes such as step-over-step stair ascent and walking on sloped surfaces. However, transitions between these locomotion modes and walking are neither automatic nor seamless. This study describes methods for construction and training of a high-level intent recognition system for a lower-limb prosthesis that provides natural transitions between walking, stair ascent, stair descent, ramp ascent, and ramp descent. Using mechanical sensors onboard a powered prosthesis, we collected steady-state and transition data from six transfemoral amputees while the five locomotion modes were performed. An intent recognition system built using only mechanical sensor data was 84.5% accurate using only steady-state training data. Including training data collected while amputees performed seamless transitions between locomotion modes improved the overall accuracy rate to 93.9%. Training using a single analysis window at heel contact and toe off provided higher recognition accuracy than training with multiple analysis windows. This study demonstrates the capability of an intent recognition system to provide automatic, natural, and seamless transitions between five locomotion modes for transfemoral amputees using powered lower limb prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Huang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542
Self-citation
Research works printed but not linked: 24
- 10.1115/1.4001139 · doi:10.1115/1.4001139
- 10.1097/JPO.0b013e3181f46b65 · DOI
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 10.1177/0278364907084588 · DOI · Paper page
- 10.1109/ICORR.2007.4428531 · DOI
- 1998, Manual for the 3c100 Otto Bock C-LEG
- 10.1109/TBME.2008.2003293 · DOI · Paper page
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- 10.1115/1.3426266 · DOI · Paper page
- 10.1053/apmr.2001.24295 · DOI · Paper page
- 10.2106/00004623-197658010-00007 · DOI · Paper page
- 10.1016/j.apmr.2006.10.030 · doi:10.1016/j.apmr.2006.10.030
- 10.1016/j.gaitpost.2006.04.008 · DOI
- 10.1682/JRRD.2005.09.0147 · DOI · Paper page
- 0, Rheo Knee
- 10.1097/00007611-200208000-00018 · DOI · Paper page
- 0, Instruction materials?Training with Genium
- leplante, 1996, Disability in the United States
- 10.1016/j.gaitpost.2003.09.006 · DOI
- 10.1109/ROBOT.2007.364114 · DOI
- 10.1007/PL00005659 · doi:10.1007/pl00005659
- 10.1109/TMECH.2009.2032688 · DOI · Paper page
- 10.1109/TNSRE.2010.2087360 · DOI · Paper page
- 10.1109/TNSRE.2012.2225640 · DOI · Paper page
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“It is noteworthy that there are relatively few studies that document the implementation of a complete hierarchical, multifunctional control structure similar to the one suggested here and have demonstrated its use in a practical setting [24,67,114-119].”
InfluentialToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationA Locomotion Intent Prediction System Based on Multi-Sensor Fusion
Chen, B., Zheng, E., & Wang, Q. (2014) · Sensors · doi:10.3390/s140712349 · Cited by 69
“proposed a recognition system capable of performing transitions between walking on level ground, ramps and stairs for a powered prosthesis, using onboard mechanical sensors [15].”
BackgroundResultXu, D., Feng, Y., Mai, J., & Wang, Q. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870152 · Cited by 67
“several discrete points (gait events) not on continuous gait phases [22], [23], [29], [30].”
BackgroundPapapicco, V., Chen, B., Munih, M., Davalli, A., Sacchetti, R., Gruppioni, E., Crea, S., & Vitiello, N. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3075096 · Cited by 19
Metadata
- Authors
- Young, A. J., Simon, A. M., & Hargrove, L. J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 671-677
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2105352020
- Cited by
- 150
- References
- 2
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Training Method for Locomotion Mode Prediction Using Powered Lower Limb Prostheses. https://app.cochat.ai/papers/10.1109/tnsre.2013.2285101
- The paper
- Young, A. J., Simon, A. M., & Hargrove, L. J. (2014). A Training Method for Locomotion Mode Prediction Using Powered Lower Limb Prostheses. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2013.2285101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.