A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring
Abstract
This paper reviews recent advances in biomedical and healthcare applications of Doppler radar that remotely detects heartbeat and respiration of a human subject. In the last decade, new front-end architectures, baseband signal processing methods, and system-level integrations have been proposed by many researchers in this field to improve the detection accuracy and robustness. The advantages of noncontact detection have drawn interests in various applications, such as energy smart home, baby monitor, cardiopulmonary activity assessment, and tumor tracking. While many of the reported systems were bench-top prototypes for concept verification, several portable systems and integrated radar chips have been demonstrated. This paper reviews different architectures, baseband signal processing, and system implementations. Validations of this technology in a clinical environment will also be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stove, A. G. (1992) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1992.0048 · Cited by 1,047
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Self-citationArctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Self-citationRandom Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Self-citationChen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
Noninvasive microwave measurement of respiration
Lin, J. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9992 · Cited by 429
Self-citationMicrowave sensing of physiological movement and volume change: A review
Lin, J. C. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130610 · Cited by 299
Self-citationAn X-Band Microwave Life-Detection System
Chen, K., Misra, D. K., Wang, H., Chuang, H.-R., & Postow, E. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325760 · Cited by 284
Xiao, Y., Lin, J., Boric-Lubecke, O., & Lubecke, M. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.873625 · Cited by 259
Self-citationA microwave radio for Doppler radar sensing of vital signs
Droitcour, A., Lubecke, V., Lin, J., & Boric-Lubecke, O. (2002) · 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157) · doi:10.1109/mwsym.2001.966866 · Cited by 252
Self-citation
Cited by
Remote Monitoring of Human Vital Signs Using mm-Wave FMCW Radar
Alizadeh, M., Shaker, G., Almeida, J. C. M. D., Morita, P. P., & Safavi-Naeini, S. (2019) · IEEE Access · doi:10.1109/access.2019.2912956 · Cited by 535
FarSense: Pushing the Range Limit of WiFi-based Respiration Sensing with CSI Ratio of Two Antennas
Zeng, Y., Wu, D., Xiong, J., Yi, E., Gao, R., & Zhang, D. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3351279 · Cited by 469
Wireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414
Terahertz Imaging and Sensing Applications With Silicon-Based Technologies
Hillger, P., Grzyb, J., Jain, R., & Pfeiffer, U. R. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2884852 · Cited by 408
A Review on Recent Progress of Portable Short-Range Noncontact Microwave Radar Systems
Li, C., Peng, Z., Huang, T.-Y., Fan, T., Wang, F.-K., Horng, T.-S., Munoz-Ferreras, J.-M., Gomez-Garcia, R., Ran, L., & Lin, J. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2650911 · Cited by 372
Self-citationMocrii, D., Chen, Y., & Musilek, P. (2018) · Internet of Things · doi:10.1016/j.iot.2018.08.009 · Cited by 348
Illuminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
“For example, sensors can measure vital signs from a distance 146 .”
BackgroundDoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar
Rahman, T., Adams, A. T., Ravichandran, R. V., Zhang, M., Patel, S. N., Kientz, J. A., & Choudhury, T. (2015) · Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2750858.2804280 · Cited by 175
Non-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar
Wang, P., Ma, Y., Liang, F., Zhang, Y., Yu, X., Li, Z., An, Q., Lv, H., & Wang, J. (2020) · Animals · doi:10.3390/ani10020205 · Cited by 45
Metadata
- Authors
- Li, C., Lubecke, V. M., Boric-Lubecke, O., & Lin, J.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2013-05
- Volume
- 61
- Issue
- 5
- Pages
- 2046-2060
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2075959322
- Cited by
- 821
- References
- 27
- FWCI
- 22.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.