Information conveyed through brain-control: cursor versus robot
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Microwire electrode arrays were implanted in the motor and premotor cortical areas of rhesus macaques. The recorded activity was used to control the three-dimensional movements of a virtual cursor and of a robotic arm in real time. The goal was to move the cursor or robot to one of eight targets. Average information conveyed about the intended target was calculated from the observed trajectories at 30-ms intervals throughout the movements. Most of the information about intended target was conveyed within the first second of the movement. For the brain-controlled cursor, the instantaneous information transmission rate was at its maximum at the beginning of each movement (averaged 4.8 to 5.5 bits/s depending on the calculation method used). However, this instantaneous rate quickly slowed down as the movement progressed and additional information became redundant. Information was conveyed more slowly through the brain-controlled robot due to the dynamics and noise of the robot system. The brain-controlled cursor data was also used to demonstrate a method for optimizing information transmission rate in the case where repeated cursor movements are used to make long strings of sequential choices such as in a typing task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“Many types of brain–computer interfaces (BCIs) have been developed for assisting the disabled [1]–[7].”
BackgroundThe information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Brain oscillations control hand orthosis in a tetraplegic
Pfurtscheller, G., Guger, C., Müller, G., Krausz, G., & Neuper, C. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)01471-3 · Cited by 472 · cited 1×
“Possible functions include choosing letters to spell words [1]–[4], moving a cursor to select from a menu, and mentally directing the motion of a robot, a wheelchair, or a neuroprosthetic limb [5], [6].”
BackgroundPeckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319 · cited 2×
“Reaching the targets could have represented selecting letters or groups of letters in a communication task, selecting options from a menu of environmental controls, or choosing between several predefined hand configurations for controlling stimulation of a paralyzed limb [12].”
BackgroundMethod
Cited by
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Self-citationFunctional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Schwartz, A. B. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.27.070203.144233 · Cited by 559
Self-citationClinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Hand Posture Subspaces for Dexterous Robotic Grasping
Ciocarlie, M. T., & Allen, P. K. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909105606 · Cited by 409
Kim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., & Black, M. J. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/010 · Cited by 397
Guest editorial brain-computer interface technology: a review of the second international meeting
Vaughan, T. M. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814799 · Cited by 352
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Real‐time fMRI using brain‐state classification
LaConte, S. M., Peltier, S. J., & Hu, X. P. (2007) · Human Brain Mapping · doi:10.1002/hbm.20326 · Cited by 255
Brain–computer interface using fMRI: spatial navigation by thoughts
Yoo, S.-S., Fairneny, T., Chen, N.-K., Choo, S.-E., Panych, L. P., Park, H., Lee, S.-Y., & Jolesz, F. A. (2004) · NeuroReport · doi:10.1097/01.wnr.0000133296.39160.fe · Cited by 252
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
“simple thresholding is still useful in the cases where only the occurrence of the spikes is of interest [23], [24].”
Background(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Decoding Continuous and Discrete Motor Behaviors Using Motor and Premotor Cortical Ensembles
Hatsopoulos, N., Joshi, J., & O'Leary, J. G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01245.2003 · Cited by 202
“These efforts have mainly focused on the continuous control of a moving object such as a computer cursor or the end effector of a robotic arm (Carmena et al. 2003; Kennedy et al. 2000; Kostov and Polak 2000; Serruya et al. 2002; Taylor et al. 2003, 2002; Wolpaw et al. 1991).”
BackgroundCoadaptive Brain–Machine Interface via Reinforcement Learning
DiGiovanna, J., Mahmoudi, B., Fortes, J., Principe, J. C., & Sanchez, J. C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926699 · Cited by 174
“Unlike many previous BMI paradigms [21]–[23], both the user and the BMI control agent must coadapt [24], [25] and continuously learn from interactions with the environment.”
BackgroundLin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133
Metadata
- Authors
- Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2003-06
- Volume
- 11
- Issue
- 2
- Pages
- 195-199
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2111685939
- Cited by
- 150
- References
- 5
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.