Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
An active ankle-foot orthoses (AAFO) is presented where the impedance of the orthotic joint is modulated throughout the walking cycle to treat drop-foot gait. During controlled plantar flexion, a biomimetic torsional spring control is applied where orthotic joint stiffness is actively adjusted to minimize forefoot collisions with the ground. Throughout late stance, joint impedance is minimized so as not to impede powered plantar flexion movements, and during the swing phase, a torsional spring-damper control lifts the foot to provide toe clearance. To assess the clinical effects of variable-impedance control, kinetic and kinematic gait data were collected on two drop-foot participants wearing the AAFO. For each participant, zero, constant, and variable impedance control strategies were evaluated and the results were compared to the mechanics of three age, weight, and height matched normals. We find that actively adjusting joint impedance reduces the occurrence of slap foot allows greater powered plantar flexion and provides for less kinematic difference during swing when compared to normals. These results indicate that a variable-impedance orthosis may have certain clinical benefits for the treatment of drop-foot gait compared to conventional ankle-foot orthoses having zero or constant stiffness joint behaviors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
A gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“The data were processed at 120 Hz with VICON Workstation [42] using the standard model of the lower limbs included with the software [43]–[45].”
MethodPratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,290
Gait Analysis: Normal and Pathological Function
Perry, J., k, S., & Davids, J. R. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199211000-00023 · Cited by 1,121
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D. J., & Pratt, G. A. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803231 · Cited by 409
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Dynamics of human ankle stiffness: Variation with mean ankle torque
Hunter, I. W., & Kearney, R. E. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90089-6 · Cited by 377
Burridge, J., Taylor, P., Hagan, S., Wood, D., & Swain, I. (1997) · Clinical Rehabilitation · doi:10.1177/026921559701100303 · Cited by 323
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275 · cited 1×
“Drop-foot gait is caused by stroke, cerebral palsy, multiple sclerosis and neurological trauma from accident or surgical complication [ 47 ].”
BackgroundComparison of three ankle–foot orthosis configurations for children with spastic diplegia
Buckon, C. E., Thomas, S. S., Jakobson-Huston, S., Moor, M., Sussman, M., & Aiona, M. (2004) · Developmental Medicine & Child Neurology · doi:10.1017/s0012162204001008 · Cited by 208
A mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
Pratt, G. A., Williamson, M. M., Dillworth, P., Pratt, J. E., & Wright, A. (1997) · Lecture notes in control and information sciences · doi:10.1007/bfb0035216 · Cited by 164
Sagittal plane characterization of normal human ankle function across a range of walking gait speeds
Palmer, M. L. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 160
Hint for squint: a computer reliant diagnostic aid for strabismus
Gieszl, L. R., Morris, J. V., & Guyton, D. L. (2005) · Symposium on Computer Applications in Medical Care (SCAMC) · doi:10.1109/scamc.1983.764787 · Cited by 157
Lum, P. S., Burgar, C. G., Kenney, D. E., & Van der Loos, H. F. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764942 · Cited by 142
Geboers, J. F., Drost, M. R., Spaans, F., Kuipers, H., & Seelen, H. A. M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.27462 · Cited by 140
Peroneal stimulator: Evaluation for the correction of spastic drop foot in hemiplegia
Granat, M. H., Maxwell, D. J., Ferguson, A., Lees, K. R., & Barbenet, J. C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90214-2 · Cited by 140
Does Neurorehabilitation Play a Role in the Recovery of Walking in Neurological Populations?a
Barbeau, H., Norman, K. E., Fung, J., Visintin, M., & Ladouceur, M. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb09063.x · Cited by 140
Comparison of three ankle‐foot orthosis configurations for children with spastic hemiplegia
Buckon, C. E., Thomas, S. S., Jakobson‐Huston, S., Moor, M., Sussman, M., & Aiona, M. (2001) · Developmental Medicine & Child Neurology · doi:10.1017/s0012162201000706 · Cited by 106
Bajd, T., Kralj, A. R., Štefančič, M., & Lavrač, N. (1999) · Artificial Organs · doi:10.1046/j.1525-1594.1999.06360.x · Cited by 102
Comparative Study of Mechanical Characteristics of Plastic AFOs
Yamamoto, S., Ebina, M., Iwasaki, M., Kubo, S., Kawai, H., & Hayashi, T. (1993) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199304000-00009 · Cited by 77
Rehabilitators, Robots, and Guides: New Tools for Neurological Rehabilitation
Reinkensmeyer, D. J., Hogan, N., Krebs, H. I., Lehman, S. L., Lum, P. S., & Newman, D. J. (2000) · Springer eBooks · doi:10.1007/978-1-4612-2104-3_39 · Cited by 67
Force-controllable ankle foot orthosis (AFO) to assist drop foot gait
Blaya, J. A. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 35
Self-citationEvaluation of effect of ankle-foot orthosis use on strength restoration of paretic dorsiflexors
Geboers, J. F., Janssen‐Potten, Y., Seelen, H. A. M., Spaans, F., & Drost, M. R. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.21863 · Cited by 19
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationSoft Robotics: A Perspective—Current Trends and Prospects for the Future
Majidi, C. (2014) · Soft Robotics · doi:10.1089/soro.2013.0001 · Cited by 1,302
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Metadata
- Authors
- Blaya, J. A., & Herr, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2004-03
- Volume
- 12
- Issue
- 1
- Pages
- 24-31
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2127927857
- Cited by
- 741
- References
- 28
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.