Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
An active ankle-foot orthoses (AAFO) is presented where the impedance of the orthotic joint is modulated throughout the walking cycle to treat drop-foot gait. During controlled plantar flexion, a biomimetic torsional spring control is applied where orthotic joint stiffness is actively adjusted to minimize forefoot collisions with the ground. Throughout late stance, joint impedance is minimized so as not to impede powered plantar flexion movements, and during the swing phase, a torsional spring-damper control lifts the foot to provide toe clearance. To assess the clinical effects of variable-impedance control, kinetic and kinematic gait data were collected on two drop-foot participants wearing the AAFO. For each participant, zero, constant, and variable impedance control strategies were evaluated and the results were compared to the mechanics of three age, weight, and height matched normals. We find that actively adjusting joint impedance reduces the occurrence of slap foot allows greater powered plantar flexion and provides for less kinematic difference during swing when compared to normals. These results indicate that a variable-impedance orthosis may have certain clinical benefits for the treatment of drop-foot gait compared to conventional ankle-foot orthoses having zero or constant stiffness joint behaviors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
A gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“The data were processed at 120 Hz with VICON Workstation [42] using the standard model of the lower limbs included with the software [43]–[45].”
MethodPratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Gait Analysis: Normal and Pathological Function
Perry, J., k, S., & Davids, J. R. (1992) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-199211000-00023 · Cited by 1,121
Series elastic actuator development for a biomimetic walking robot
Robinson, D. W., Pratt, J. E., Paluska, D. J., & Pratt, G. A. (1999) · 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399) · doi:10.1109/aim.1999.803231 · Cited by 409
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationSoft Robotics: A Perspective—Current Trends and Prospects for the Future
Majidi, C. (2014) · Soft Robotics · doi:10.1089/soro.2013.0001 · Cited by 1,302
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D. (2009) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2009.933629 · Cited by 834
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“For example, brushless dc motors have been used for an ankle rehabilitation robot [18], as well as in series elastic actuators with a rigid plastic AFO frame [15, 19].”
BackgroundMethodExoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Self-citationRecent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Kong, K., Bae, J., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2004561 · Cited by 426
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation
Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., & Hogan, N. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019783 · Cited by 337
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe
Kong, K., & Tomizuka, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.2008803 · Cited by 301
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationAssistive mobility devices focusing on Smart Walkers: Classification and review
Martins, M. M., Santos, C. P., Frizera-Neto, A., & Ceres, R. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2011.11.015 · Cited by 260
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
A light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
Mechanical performance of artificial pneumatic muscles to power an ankle–foot orthosis
Gordon, K. E., Sawicki, G. S., & Ferris, D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.018 · Cited by 223
“Two other powered ankle–foot orthoses have previously been described (Andersen and Sinkjaer, 1995, 2003; Blaya and Herr, 2004).”
BackgroundMethodRehabilitation Exoskeletal Robotics
Pons, J. L. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936548 · Cited by 222
“Other authors [16] use conventional actuator technologies, e.”
Wearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
“[77] Blaya JA, Herr H.”
MethodBiomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
Variable Impedance Control and Learning—A Review
Abu-Dakka, F. J., & Saveriano, M. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.590681 · Cited by 214
“In rehabilitation, Blaya and Herr (2004) implemented a VIC for an ankle-foot orthosis.”
BackgroundManufacture of Passive Dynamic Ankle–Foot Orthoses Using Selective Laser Sintering
Faustini, M. C., Neptune, R. R., Crawford, R. H., & Stanhope, S. J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912638 · Cited by 209
“For the purpose of this study, the classification active dynamic orthosis contains those devices that use motors [1], pumps [2], and actuators [3] to actively control the magnitude of joint assistance and level of mechanical energy transferred.”
MethodDevelopment of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
A PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185
Development of single leg version of HAL for hemiplegia
Kawamoto, H., Hayashi, T., Sakurai, T., Eguchi, K., & Sankai, Y. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333698 · Cited by 182
A portable powered ankle-foot orthosis for rehabilitation
Shorter, K. A., Kogler, G. F., Loth, E., Durfee, W. K., & Hsiao-Wecksler, E. T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.04.0054 · Cited by 180
“The SEAs used by Blaya and Herr [9] and Boehler et al.”
MethodHobbs, B., & Artemiadis, P. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00019 · Cited by 178
“Another active ankle-foot orthosis presented in Blaya and Herr (2004) tests the idea of modulating impedance of the orthotic joint throughout the gait cycle to treat drop-foot gait.”
BackgroundA Tutorial Survey and Comparison of Impedance Control on Robotic Manipulation
Song, P., Yu, Y., & Zhang, X. (2019) · Robotica · doi:10.1017/s0263574718001339 · Cited by 169
Soft exosuit for hip assistance
Asbeck, A. T., Schmidt, K., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.025 · Cited by 167
Bio-inspired active soft orthotic device for ankle foot pathologies
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094933 · Cited by 130
“Previous work has shown the efficacy of adaptive control with active devices [4].”
BackgroundFusion of Multi-Sensor-Based Biomechanical Gait Analysis Using Vision and Wearable Sensor
Bijalwan, V., Semwal, V. B., & Mandal, T. K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3066473 · Cited by 122
(2008) · doi:10.1109/aim.2008.4601855 · Cited by 15
“motion capture system for objective diagnoses [1] and humancentered robots for assistance [2-6] and for rehabilitation [79].”
Background
Metadata
- Authors
- Blaya, J. A., & Herr, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2004-03
- Volume
- 12
- Issue
- 1
- Pages
- 24-31
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2127927857
- Cited by
- 741
- References
- 28
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.