CoChat

Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation

Open access
Roetenberg, D., Luinge, H.J., Baten, C.T.M., Veltink, P.H. · 2005 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 588

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

This paper describes a complementary Kalman filter design to estimate orientation of human body segments by fusing gyroscope, accelerometer, and magnetometer signals from miniature sensors. Ferromagnetic materials or other magnetic fields near the sensor module disturb the local earth magnetic field and, therefore, the orientation estimation, which impedes many (ambulatory) applications. In the filter, the gyroscope bias error, orientation error, and magnetic disturbance error are estimated. The filter was tested under quasi-static and dynamic conditions with ferromagnetic materials close to the sensor module. The quasi-static experiments implied static positions and rotations around the three axes. In the dynamic experiments, three-dimensional rotations were performed near a metal tool case. The orientation estimated by the filter was compared with the orientation obtained with an optical reference system Vicon. Results show accurate and drift-free orientation estimates. The compensation results in a significant difference (p < 0.01) between the orientation estimates with compensation of magnetic disturbances in comparison to no compensation or only gyroscopes. The average static error was 1.4 degrees (standard deviation 0.4) in the magnetically disturbed experiments. The dynamic error was 2.6 degrees root means square.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2005.847353

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 8

  1. 10.1016/S0140-3664(02)00249-9 · doi:10.1016/s0140-3664(02)00249-9
  2. Geomagnetism, P.N
  3. Xsens
  4. Baten, Estimating body segment body orientation applying inertial sensing
  5. 10.4271/970602 · doi:10.4271/970602
  6. 10.1016/S0924-4247(01)00860-3 · doi:10.1016/s0924-4247(01)00860-3
  7. 10.1061/(ASCE)0893-1321(2003)16:2(65) · doi:10.1061/(asce)0893-1321(2003)16:2(65
  8. 2003, Analog Devices

Cited by

See all 588

Metadata

Authors
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2005-09
Volume
13
Issue
3
Pages
395-405
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2155067987
Cited by
588
References
29
FWCI
35.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.