CoChat

Evaluation of the stability of intracortical microelectrode arrays

Xindong Liu, McCreery, D.B., Bullara, L.A., Agnew, W.F. · 2006 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 84

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In order to use recorded neural activities from the brain as control signals for neuroprosthesis devices, it is important to maintain a stable interface between chronically implanted microelectrodes and neural tissue. Our previous paper introduced a method to quantify the stability of the recording microelectrodes. In this paper, the method is refined 1) by incorporating stereotypical behavioral patterns into the spike sorting program and 2) by using a classifier based on Bayes theorem for assigning the recorded action potentials to the underlying neural generators. An improved method for calculating stability index is proposed. The results for the stability of microelectrode arrays that differ in structure are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2006.870495

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 84

Metadata

Authors
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2006-03
Volume
14
Issue
1
Pages
91-100
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2157953129
Cited by
84
References
3
FWCI
1.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the stability of intracortical microelectrode arrays. https://app.cochat.ai/papers/10.1109/tnsre.2006.870495
The paper
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006). Evaluation of the stability of intracortical microelectrode arrays. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2006.870495

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.