Evaluation of the stability of intracortical microelectrode arrays
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In order to use recorded neural activities from the brain as control signals for neuroprosthesis devices, it is important to maintain a stable interface between chronically implanted microelectrodes and neural tissue. Our previous paper introduced a method to quantify the stability of the recording microelectrodes. In this paper, the method is refined 1) by incorporating stereotypical behavioral patterns into the spike sorting program and 2) by using a classifier based on Bayes theorem for assigning the recorded action potentials to the underlying neural generators. An improved method for calculating stability index is proposed. The results for the stability of microelectrode arrays that differ in structure are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · cited 2×
“implantation techniques have also made it possible for the implanted microelectrodes to achieve a long-term interface with the neural tissue [7]–[12].”
BackgroundSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“implantation techniques have also made it possible for the implanted microelectrodes to achieve a long-term interface with the neural tissue [7]–[12].”
Background
Cited by
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(16, 17) Additionally, recently Ludwig et al.”
Background
Metadata
- Authors
- Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-03
- Volume
- 14
- Issue
- 1
- Pages
- 91-100
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2157953129
- Cited by
- 84
- References
- 3
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the stability of intracortical microelectrode arrays. https://app.cochat.ai/papers/10.1109/tnsre.2006.870495
- The paper
- Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006). Evaluation of the stability of intracortical microelectrode arrays. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2006.870495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.