Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Long-term viability of chronic invasive neural probes is a necessary condition for extracting robust control signals directly from neural tissue. Although immune/tissue response is a leading factor in the degradation of single neuron recording, we investigate a second component of signal degradation connected to the structural changes associated with microwire electrodes chronically exposed to extracelluar environments in vivo. Scanning electron microscopy is used to assess the surface modifications to the electrodes after an implantation duration of four weeks in rats. The electrode developed a smooth fracture surface, a reduction of the metal diameter, and pitting in the insulation of the electrode structure. Over the duration of implantation, recording properties of the electrode were marked by a reduction in the peak-to-peak amplitude in neuronal firing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240 · cited 3×
“Moreover, the electrodes exhibited smaller dimensions (white bar represents 100 m). Prior studies have demonstrated that tungsten metal is chronically unstable within the brain physiological environment [ 9 ].”
BackgroundInfluentialCeramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129 · cited 2×
“[ 7 ] S. Musallam, B. D. Corneil, B. Greger, H. Scherberger, and R. A. An-”
Background
Cited by
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
“record from large neuronal populations and an in-depth comprehensive study such as this allows us to compare performance with the literature that exists for these electrodes [26, 27, 52, 65–69].”
ResultSelf-citationMechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274
“However, a number of mechanical failure modes can be attributed to the reactive inflammatory environment, including oxidation and corrosion of the device [6, 7].”
Background
Metadata
- Authors
- Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2006-06
- Volume
- 14
- Issue
- 2
- Pages
- 217-221
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1983035812
- Cited by
- 45
- References
- 4
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study. https://app.cochat.ai/papers/10.1109/tnsre.2006.875581
- The paper
- Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R. (2006). Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2006.875581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.