Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
For gait rehabilitation robots, an important question is how to ensure stable gait, while avoiding any interaction forces between robot and human in case the patient walks correctly. To achieve this, the definition of "correct" gait needs to adapted both to the individual patient and to the situation. Recently, we proposed a method for online trajectory generation that can be applied for hemiparetic subjects. Desired states for one (disabled) leg are generated online based on the movements of the other (sound) leg. An instantaneous mapping between legs is performed by exploiting physiological interjoint couplings. This way, the patient generates the reference motion for the affected leg autonomously. The approach, called Complementary Limb Motion Estimation (CLME), is implemented on the LOPES gait rehabilitation robot and evaluated with healthy subjects in two different experiments. In a previously described study, subjects walk only with one leg, while the robot's other leg acts as a fake prosthesis, to simulate complete loss of function in one leg. This study showed that CLME ensures stable gait. In a second study, to be presented in this paper, healthy subjects walk with both their own legs to assess the interference with self-determined walking. Evaluation criteria are: Power delivered to the joints by the robot, electromyography (EMG) distortions, and kinematic distortions, all compared to zero torque control, which is the baseline of minimum achievable interference. Results indicate that interference of the robot is lower with CLME than with a fixed reference trajectory, mainly in terms of lowered exchanged power and less alteration of EMG. This implies that subjects can walk more naturally with CLME, and they are assisted less by the robot when it is not needed. Future studies with patients are yet to show whether these properties of CLME transfer to the clinical domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jolliffe, I. (2005) · Encyclopedia of Statistics in Behavioral Science · doi:10.1002/0470013192.bsa501 · Cited by 14,310
LIII. On lines and planes of closest fit to systems of points in space
Pearson, K. (1901) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440109462720 · Cited by 11,934 · cited 1×
“We have investigated two simple linear ones among them: PCA [ 38 ], [39], which is frequently used to analyze joint synergies, e.g., in [24], and BLUE from standard linear regression [40].”
MethodThe co-ordination and regulation of movements
(1969) · Brain Research · doi:10.1016/0006-8993(69)90278-9 · Cited by 5,043
The co-ordination and regulation of movements
Foley, J. (1968) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(68)90166-4 · Cited by 3,420
Optimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746 · cited 1×
“The important question remains what the “correct” motion is. Although it is possible to generate trajectories for a given task that resemble the average pattern of a healthy subject, e.g., using optimization [ 13 ], such a reference is not tailored to the individual patient and situation.”
BackgroundTreadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Taub, E., Uswatte, G., & Pidikiti, R. D. (1999) · PubMed · Cited by 1,168
IV.—On Least Squares and Linear Combination of Observations
Aitken, A. C. (1936) · Proceedings of the Royal Society of Edinburgh · doi:10.1017/s0370164600014346 · Cited by 948
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
(2003) · Technometrics · doi:10.1198/tech.2003.s783 · Cited by 908
Cited by
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Non-phase-based controllers Complementary Limb Motion Estimation (CLME) infers the intended motion of affected limbs from the motion of the residual limbs, and maps this to a reference trajectory for robotic P/O joints to track [191].”
Self-citationRecent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“Vallery et al [63] (Zurich, Switzerland) also proposed an online trajectory generation method, called the “complementary limb motion estimation,” which is applied for hemiparetic patients.”
MethodRecent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
Powered Hip Exoskeletons Can Reduce the User's Hip and Ankle Muscle Activations During Walking
Lenzi, T., Carrozza, M. C., & Agrawal, S. K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2248749 · Cited by 215
Simon, A. M., Ingraham, K. A., Fey, N. P., Finucane, S. B., Lipschutz, R. D., Young, A. J., & Hargrove, L. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099387 · Cited by 207
“Powered devices use a variety of control methods such as finite state machines in combination with an impedance-based model [7], artificial reflexes [8], or complementary motion estimation [9].”
BackgroundOscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
“This rehabilitative control strategy, commonly referred as ‘‘assist-as-needed’’, has been proved to be an effective way to increase the outcome of robot-mediated rehabilitation therapy by promoting motor recovery [1, 11, 12, 45, 54].”
BackgroundMethodInfluentialSelf-citationHuman–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
“Complementing other approaches based on compliance [5], [ 6 ], [52], [53], adaptation [5], [54], or adaptive learning of a dynamical model for the task at hand [55], our method opens new perspectives for providing assistance-as-needed based on movement primitives.”
BackgroundMethodCao, J., Xie, S. Q., Das, R., & Zhu, G. L. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.005 · Cited by 153
“CLME was implemented on LOPES gait rehabilitation robot and evaluation studies were also conducted, which indicates that (1) CLME was able to produce stable gait for the impaired leg; (2) patients can walk more naturally with CLME than with a fixed reference trajectory [69,70].”
MethodWang, Y., Cheng, X., Jabban, L., Sui, X., & Zhang, D. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3167686 · Cited by 70
EMG and Joint Angle-Based Machine Learning to Predict Future Joint Angles at the Knee
Coker, J., Chen, H., Schall, M. C., Gallagher, S., & Zabala, M. (2021) · Sensors · doi:10.3390/s21113622 · Cited by 56
“In lieu of leveraging gait phase information, actuation information may be inferred based on movements of other body segments [19].”
BackgroundAdaptive oscillators with human-in-the-loop: Proof of concept for assistance and rehabilitation
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Chiara Carrozza, M., & Ijspeert, A. J. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5628021 · Cited by 52
Oscillator-based walking assistance: A model-free approach
Ronsse, R., Koopman, B., Vitiello, N., Lenzi, T., De Rossi, S. M. M., van den Kieboom, J., van Asseldonk, E., Carrozza, M. C., van der Kooij, H., & Ijspeert, A. J. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975352 · Cited by 50
“3), a treadmill-based lower-limb exoskeleton developed at the University of Twente [9], [19]–[21], and capable of assisting 8 DOFs of the lower-limbs (right and left hip abduction/adduction, hip flexion/extension, and knee flexion/extension, forward/backward and sideways movements of the pelvis) by providing torques t…”
BackgroundMethod
Metadata
- Authors
- Vallery, H., van Asseldonk, E. H. F., Buss, M., & van der Kooij, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-02
- Volume
- 17
- Issue
- 1
- Pages
- 23-30
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2099297971
- Cited by
- 228
- References
- 41
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.