Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Gait rehabilitation robots are of increasing importance in neurorehabilitation. Conventional devices are often criticized because they are limited to reproducing predefined movement patterns. Research on patient-cooperative control strategies aims at improving robotic behavior. Robots should support patients only as much as needed and stimulate them to produce maximal voluntary efforts. This paper presents a patient-cooperative strategy that allows patients to influence the timing of their leg movements along a physiologically meaningful path. In this "path control" strategy, compliant virtual walls keep the patient's legs within a "tunnel" around the desired spatial path. Additional supportive torques enable patients to move along the path with reduced effort. Graphical feedback provides visual training instructions. The path control strategy was evaluated with 10 healthy subjects and 15 subjects with incomplete spinal cord injury. The spatio-temporal characteristics of recorded kinematic data showed that subjects walked with larger temporal variability with the new strategy. Electromyographic data indicated that subjects were training more actively. A majority of iSCI subjects was able to actively control their gait timing. Thus, the strategy allows patients to train walking while being helped rather than controlled by the robot.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and others have successfully been applied in rehabilitation, focusing also on limb and endeffector movements (Duschau-Wicke, von Zitewitz, Caprez, Lunenburger, & Riener, 2010;Holden & Dyar, 2002;Holden, Todorov, Callahan, & Bizzi, 1999).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
In the citing paper
“The haptic assist-as-needed strategy allows patients to control their movements, while still being provided sufficient guidance and support depending on the deviation from the target movement (Duschau-Wicke et al., 2010).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Nonparametric Statistical Inference
(2012) · SpringerReference · doi:10.1007/springerreference_205502 · Cited by 2,386
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Linear Mixed Models: A Practical Guide Using Statistical Software
West, B. T., Welch, K. B., & Gałecki, A. T. (2006) · Thammasat University Digital Collections · Cited by 1,382
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Self-citationRehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714
Pohl, M., Mehrholz, J., Ritschel, C., & Rückriem, S. (2002) · Stroke · doi:10.1161/hs0202.102365 · Cited by 508
Research works printed but not linked: 2
- von zitzewitz, 2006, path control: a new approach in patient-cooperative gait training with the rehabilitation robot lokomat, Joint Meet German Austrian Swiss Soc Biomed Eng
- hermens, 1999, European Recommendations for Surface Electromyography
Cited by
Items 201–300 of 424
Rouse, C. A., Cousin, C. A., Allen, B. C., & Dixon, W. E. (2020) · Automatica · doi:10.1016/j.automatica.2020.109294 · Cited by 12
Koenig, A. C., & Riener, R. (2016) · Springer eBooks · doi:10.1007/978-3-319-28603-7_9 · Cited by 14
Self-citationPezeshki, L., Sadeghian, H., Mohebbi, A., Keshmiri, M., & Haddadin, S. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3552446 · Cited by 11
“In [13] a path control strategy is proposed, employing a basic impedance controller to generate a force field.”
InfluentialMartínez, A., Lawson, B. E., & Goldfarb, M. T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512807 · Cited by 11
An adaptive seamless assist-as-needed control scheme for lower extremity rehabilitation robots
Zhang, X., Yin, G., Li, H., Dong, R., & Hu, H. (2020) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651820970720 · Cited by 15
Three-Dimensional Multi-degree-of-Freedom Arm Therapy Robot (ARMin)
Nef, T., Klamroth-Marganska, V., Keller, U., & Riener, R. (2016) · Springer eBooks · doi:10.1007/978-3-319-28603-7_17 · Cited by 13
Self-citationControl Algorithms in Robot-Assisted Rehabilitation: A Systematic Review
Rad, O. L., & Brișan, C. (2025) · Applied Sciences · doi:10.3390/app15169184 · Cited by 18
Biomechanics of Exoskeleton-Assisted Treadmill Walking
Tommaso, F. D., Tamburella, F., Lorusso, M., Gastaldi, L., Molinari, M., & Tagliamonte, N. L. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304685 · Cited by 13
“Electromyography (EMG) has also been used to assess the quality of human-exoskeleton interaction [8]–[11], even in combination with additional kinetics-based metrics [7], [12].”
BackgroundMethodLeerskov, K., Rikhof, C. J. H., Spaich, E. G., Dosen, S. S., Prange-Lasonder, G. B., Prinsen, E. C., Rietman, J. S., & Struijk, L. N. S. A. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108839 · Cited by 15
Coordinated human-exoskeleton locomotion emerges from regulating virtual energy
Nasiri, R., Dinovitzer, H., Manohara, N., & Arami, A. (2025) · PLoS ONE · doi:10.1371/journal.pone.0292334 · Cited by 10
Naghavi, N., Akbarzadeh, A., Khaniki, O., Kardan, I., & Moradi, A. (2023) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-023-01854-x · Cited by 10
“The original method in [12] uses a constant boundary for the tunnel.”
BackgroundMethodInfluentialA Learning-Based Shared Control Approach for Contact Tasks
Michel, Y., Li, Z., & Lee, D. (2023) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2023.3322332 · Cited by 10
“In this regard, two prominent control strategies can be distinguished: path [1] and flow Control [2].”
MethodOn the control of the MIT-Skywalker
Artemiadis, P., & Krebs, H. I. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626407 · Cited by 12
“More recently ETH Zurich initiated pilot testing on an improved version of their software that affords a more interactive experience [ 12 ].”
MethodA novel approach for robot-assisted upper-limb rehabilitation
Xu, G., Gao, X., Chen, S., Wang, Q., Zhu, B., & Li, J. (2017) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881417736670 · Cited by 10
Path Control of a Rehabilitation Robot Using Virtual Tunnel and Adaptive Impedance Controller
Ding, B., Ai, Q., Liu, Q., & Meng, W. (2014) · International Symposium on Computational Intelligence and Design · doi:10.1109/iscid.2014.204 · Cited by 10
“With the previous rehabilitation robotic devices, such as the Lokomat and Gait Trainer, patients often followed the predefined trajectories and without personal voluntary participation[4].”
BackgroundMethodMeng, W., Zhu, Y., Zhou, Z., Chen, K., & Ai, Q. (2014) · IEEE International Conference on Fuzzy Systems (FUZZ-IEEE) · doi:10.1109/fuzz-ieee.2014.6891705 · Cited by 10
“presented a path control strategy with a virtual wall to keep the patient’s legs within a tunnel around the desired path, again, a constant treadmill speed was used throughout the experiments [11].”
BackgroundMethodIyer, S. S., Joseph, J. V., & Vashista, V. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00015 · Cited by 10
“This is of interest, especially because some of the reported gait rehabilitation paradigms have successfully used robotic leg exoskeletons to apply external forces at multiple leg joints to achieve a desired foot trajectory performance by a hemiparetic stroke patient (Duschau-Wicke et al., 2009; Krishnan et al., 2012;…”
BackgroundMethodInfluentialdel‐Ama, A. J., Moreno, J. C., Gil-Agudo, A. M., & Pons, J. L. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-34546-3_25 · Cited by 10
Jensen, E., Peper, K. K., Egger, M., Müller, F., Shahriari, E., & Haddadin, S. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3323390 · Cited by 9
“To address this, robot control strategies have been developed to intelligently adapt the support level to the needs of the patient (“assist-as-needed”, AAN), e.g. using machine learning approaches [22], [23], [24].”
MethodZou, C., Peng, Z., Zhang, L., Mu, F., Huang, R., & Cheng, H. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3384515 · Cited by 9
“Lokomat is a bilateral gait orthosis for treadmill based robotic gait training [8], which provides a human-like walking posture with body weight support and a COM transfer behaviour control, as well as some impedance control based assist-as-needed control strategies [9].”
On a Robotic Application for Rehabilitation Systems Dedicated to Kids Affected by Cerebral Palsy
Maalej, B., Jribi, R., Ayadi, N., Abdelhedi, F., & Derbel, N. (2018) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd.2018.8570561 · Cited by 9
“However, the trajectories in path control mode can be modified, we are talking about spatial and temporal freedom while a moving force guides patients to walk at the speed of the treadmill, in addition, the suspension system support provides additional forces in the direction of the walking trajectory to overcome musc…”
BackgroundXie, P., Qiu, S., Li, X., Du, Y., Wu, X., & Guo, Z. (2016) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2016.7832015 · Cited by 9
“Besides, the adjustable threshold ε is introduced to compensate jitter error of lower limb and provide force-space window [14] where the subject can change active force freely.”
BackgroundMcGrath, R. L., Pires-Fernandes, M., Knarr, B. A., Higginson, J. S., & Sergi, F. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009258 · Cited by 10
“While the initial approaches lacked interaction control capabilities, later work presented assistance schemes based on the Assist-As-Needed (AAN) principle [6]–[8].”
Method(1995) · Series in medical physics and biomedical engineering · doi:10.1201/9781420050325.ch12 · Cited by 9
Technology of the Robotic Gait Orthosis Lokomat
Marchal–Crespo, L., & Riener, R. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_29 · Cited by 11
Self-citationShima, K., & Shimatani, K. (2016) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.2016.7824200 · Cited by 9
Aurich-Schuler, T., & Labruyère, R. (2019) · Frontiers in Robotics and AI · doi:10.3389/frobt.2019.00109 · Cited by 11
“Path Control offers a spatiotemporal tunnel around the predefined gait trajectory in the sagittal plane which allows a certain degree of individualization (Duschau-Wicke et al., 2010a; Schück et al., 2012).”
Background[Research on assist-as-needed control strategy of wrist function-rehabilitation robot].
Wang, J., Zuo, G., Zhang, J., Shi, C., Song, T., & Guo, S. (2020) · PubMed Central · doi:10.7507/1001-5515.201902023 · Cited by 10
de Miguel-Fernández, J., Lobo-Prat, J., Prinsen, E. C., Font-Llagunes, J. M., & Marchal–Crespo, L. (2022) · Research Square · doi:10.21203/rs.3.rs-1195778/v1 · Cited by 10
Belalcázar-Bolaños, E. A., Torricelli, D., & Pons, J. L. (2023) · Sensors · doi:10.3390/s23249683 · Cited by 12
“A large body of the literature has been devoted to investigating human movement under different perspectives, such as movement mechanisms [27–30], rehabilitation [31–33], robotic aids [34–37], or exercising with the help of a virtual trainer [38–40].”
BackgroundAdaptive Control for Triadic Human-Robot-FES Collaboration in Gait Rehabilitation: A Pilot Study
Christou, A., del‐Ama, A. J., Moreno, J. C., & Vijayakumar, S. (2024) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57147.2024.10611133 · Cited by 8
“As our starting point we deploy a Hybrid Path Controller – a controller that follows the principles of Path Control [34], and provides assistance using a wearable robot and FES.”
MethodAi, X., Santamaria, V., Chen, J., Hu, B., Zhu, C., & Agrawal, S. K. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3221308 · Cited by 8
“These methods have been used in the training of various human movements [8], [9].”
MethodChen, Y., Hu, J. P., Wang, W., Peng, L., Peng, L., & Hou, Z. (2013) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2013.6739769 · Cited by 9
“xd in (9) is the desired position for the end-point on the predefined trajectory at a specific time point, and xd is moving towards the target point at a constant speed, meaning a “virtual moving wall” is pushing the patient towards the target [5].”
BackgroundJumping motion planning for biped robot based on hip and knee joints coordination control
Bian, Y., Shao, J., Yang, J., & Liang, A. (2021) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-021-0236-6 · Cited by 8
Ye, X., Chen, C., Shi, Y., Chen, L., Wang, Z., Zhang, Z., Liu, Y., & Wu, X. (2021) · Micromachines · doi:10.3390/mi12101150 · Cited by 11
“Most lower extremity exoskeletons have a rigid structure with great supportability, and have been successfully applied to the rehabilitation of incapacitated patients [5].”
BackgroundTanaka, T., Matsumura, R., & Miura, T. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19159713 · Cited by 8
“Robot therapy is actively being researched from the viewpoint of motor learning and has a clinical application in rehabilitation [8,9].”
BackgroundDesign and control of a 3-DOF rehabilitation robot for forearm and wrist
Luo, L., Peng, L., Hou, Z., & Wang, W. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037764 · Cited by 8
“Inspired by the virtual tunnel proposed by Duschau-Wicke [12], we applied a “moving window” along with the reference trajectory, where the robot will not provide assistant forces when the patient moves within or ahead of the window.”
MethodFeasibility of Gait Entrainment to Hip Mechanical Perturbation for Locomotor Rehabilitation
Lee, J., Goetz, D., Huber, M. E., & Hogan, N. (2019) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8968024 · Cited by 9
“Conventional therapeutic robots for walking impose preplanned repetitive kinematic trajectories on patients using high-gain trajectory tracking controllers [8], [9].”
BackgroundOn the stiffness analysis of a cable driven leg exoskeleton
Nakka, S., & Vashista, V. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009290 · Cited by 8
Wang, Y., Guo, Y., Tao, Y., Tian, Y., & Wang, H. (2023) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.6996 · Cited by 8
“One is the position tracking error-based AAN (PTEAAN) impedance controller proposed in the work of Duschau-Wicke et al. 22 The width of the tunnel is fixed and selected based on experience.”
Patient cooperative adaptive controller for lower limb Robotic Rehabilitation Device
Anwar, T., & Al-Jumaily, A. A. (2014) · IEEE International Advance Computing Conference · doi:10.1109/iadcc.2014.6779542 · Cited by 7
“But it is evident that RRD focusing on activity of daily living (ADL) increases patients motivation to participate in training which result in a better outcome rather than therapies focusing on single joint only.”
BackgroundMethodInfluentialOn the potential field-based control of the MIT-Skywalker
Artemiadis, P., & Krebs, H. I. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980063 · Cited by 8
“a more interactive experience [16], using a similarly defined impedance controller.”
Gesteme-free context-aware adaptation of robot behavior in human–robot cooperation
Nessi, F., Beretta, E., Gatti, C., Ferrigno, G., & Momi, E. D. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.10.001 · Cited by 8
“enable patients to train in an active, variable and more natural way, with more physiological muscle activity [10].”
BackgroundWeiland, S., Smit, I. H., Reinders‐Messelink, H. A., van der Woude, L. H. V., van Kammen, K., & den Otter, R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198473 · Cited by 9
“However, as the compensatory torques generated by the Lokomat actuators do not fully eliminate interaction torques due to exoskeleton inertia, friction, and gravity [31], this may necessitate a more active control of the swing limb during Lokomat guided walking, in particular at low guidance settings [9,11].”
BackgroundZhou, J., Yang, R., Lyu, Y., & Song, R. (2020) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm49381.2020.9195367 · Cited by 7
“Moreover, the tracking trajectory (in green) can be effectively restricted in the preset joint space even under different types of disturbances and system uncertainties, which is similar to the results in [14].”
BackgroundResultZou, C., Zeng, C., Huang, R., Peng, Z., Zhang, J., & Cheng, H. M. (2023) · Robotica · doi:10.1017/s0263574723001431 · Cited by 8
“…the basic idea is to construct an artificial potential field around the reference position or velocity trajectory and force the robot to move around them, including force field control in Cartesian space [17], velocity field control in Cartesian space [18], and path control in joint space [19].”
BackgroundGait Adaptation to Asymmetric Hip Stiffness Applied by a Robotic Exoskeleton
Abdikadirova, B., Price, M. A., Jaramillo, J. M., Hoogkamer, W., & Huber, M. E. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3354517 · Cited by 12
“A stiffness-based intervention also encourages participants to actively engage in the task [21] and allows them to adjust their gait in response to the applied intervention.”
BackgroundA new impedance control structure for leg Rehabilitation Robot
Mirzaei, A., & Ozgoli, S. (2011) · International Conference on Control, Instrumentation, and Automation · doi:10.1109/icciautom.2011.6356790 · Cited by 7
“But this kind of training is time consuming and demands for several therapists, thus researchers think about new and more automated strategies for rehabilitation [3].”
BackgroundZhang, X., Wenliang, G., Fu, H., Chen, R., Luo, T., & Hashimoto, M. (2018) · Mathematical Problems in Engineering · doi:10.1155/2018/9279627 · Cited by 8
“We believe that the CPG network-based framework presented in this article nicely complements other approaches based on compliance [28–31], adaptation [28, 32, 33], or adaptive learning of a dynamical model for the task at hand [34].”
MethodMcGrath, R. L., & Sergi, F. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779426 · Cited by 7
Position-based High Backdrivable Control Using Load-side Encoder and Backlash
Yamada, S., & Fujimoto, H. (2020) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.20004583 · Cited by 7
Implementation of Impedance Control for Lower-Limb Rehabilitation Robots
Zhou, Y., She, J., Liu, Z., Xu, C. Y., & Yang, Z. (2021) · IEEE International Conference on Industrial Cyber-Physical Systems (ICPS) · doi:10.1109/icps49255.2021.9468210 · Cited by 10
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Mechanisms and machine science · doi:10.1007/978-3-030-20131-9_190 · Cited by 9
An, Q., Ishikawa, Y., Wen, W., Ishiguro, S., Ohata, K., Yamakawa, H., Tamura, Y., Yamashita, A., & Asama, H. (2019) · International Journal of Automation Technology · doi:10.20965/ijat.2019.p0271 · Cited by 7
Virtual Holonomic Constraints for Euler-Lagrange Control Systems
Mohammadi, A. (2016) · TSpace (University of Toronto) · doi:10.13140/rg.2.2.36834.53446 · Cited by 9
A Home-Based Self-Powered Rehabilitation System With Variable Stiffness Mechanism
Shi, K., Gao, Y., Zhang, M., Zhu, L., & Song, A. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3582255 · Cited by 5
Cao, Y., Ma, S., Zhang, M., Liu, J., Huang, J., & Zhang, Z. (2025) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2025.3611266 · Cited by 8
“For assessing human motor abilities, common methods in AAN include position/velocity-based [5], [6], force-based [7], position-force hybrid-based [8], [9], and surface electromyography (sEMG)-based approaches [10], [11], [12].”
Su, C., Chai, A., Tu, X., Zhou, H., Wang, H., Zheng, Z., Cao, J., & He, J. (2017) · International Journal of Pattern Recognition and Artificial Intelligence · doi:10.1142/s0218001417590212 · Cited by 8
Robot-Aided Gait Training with LOPES
van Asseldonk, E. H. F., & van der Kooij, H. (2016) · Springer eBooks · doi:10.1007/978-3-319-28603-7_22 · Cited by 6
Review of Key Technologies for Developing Personalized Lower Limb Rehabilitative Exoskeleton Robots
Tao, J., & Zhou, Z. (2022) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-022-2452-3 · Cited by 8
“To shed some light on individualized gait trajectory planning, Duschauwicke et al. [46-47] presented a patient-cooperative strategy that allows patients to in-fluence their leg movements’ timing along a physiologically meaningful path.”
Model-Agnostic Personalized Knowledge Adaptation for Soft Exoskeleton Robot
Li, N., Chen, W., Yang, Y., Wang, Y., Yang, T. Y., Yu, P., Zhang, C., Wang, W., Xi, N., & Liu, L. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3258505 · Cited by 7
“…controls that can change the equivalent stiffness of robotic systems and realize compliance controls have been successfully used in the human-exoskeleton system with accurate model to achieve appropriate control strategies by real-time adjusting the parameters of HRI models [13], [14], [15], [16].”
MethodHussein, S., & Krüger, J. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975451 · Cited by 6
Hussein, S., Buchel, M., & Krüger, J. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980396 · Cited by 6
“for the Lokomat [12], LOPES [13] or ALEX [14].”
MethodInteractive control methods for rehabilitation robot
Liang, X., Wang, W., Hou, Z., Ren, S., Peng, L., & Jin, H. (2017) · Scientia Sinica Informationis · doi:10.1360/n112017-00072 · Cited by 12
Luo, L., Peng, L., Hou, Z., & Wang, W. (2017) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2017.8324471 · Cited by 6
“presented a “path control” strategy, which kept the patient’s legs within a “tunnel” using a virtual wall [8].”
BackgroundAdaptive Trajectory Control to Achieve Smooth Interaction Force in Robotic Rehabilitation Device
Anwar, T., & Al-Jumaily, A. A. (2014) · Procedia Computer Science · doi:10.1016/j.procs.2014.11.047 · Cited by 6
“Thirdly, musculoskeletal model is used to define trajectory, since 27 musculo tendon actuators and joint stiffness of the leg generated trajectory is also implemented in many RRD[4].”
BackgroundMethodInfluentialKoenig, A. C., & Riener, R. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_3 · Cited by 6
Self-citationA novel approach for representing and generalising periodic gaits
Lin, H.-C., Howard, M., & Vijayakumar, S. (2014) · Robotica · doi:10.1017/s026357471400188x · Cited by 7
Home-Based Rehabilitation: Enabling Frequent and Effective Training
Reed, K. B., Handz̆ić, I., & McAmis, S. (2014) · Trends in augmentation of human performance · doi:10.1007/978-94-017-8932-5_14 · Cited by 7
“mode, or path control [101], which allows patients to freely move their limbs while walking.”
BackgroundDesign of Six-Axis Force/Moment Sensor for Ankle-Rehabilitation Robot
Kim, Y.-G., & Kim, G.-S. (2013) · Journal of Institute of Control Robotics and Systems · doi:10.5302/j.icros.2013.13.1865 · Cited by 5
“그외 재활로봇[3-8]은 환자 의 하지에 힘증강시스템(로봇)을 부착하고 상체를 끈을 이용 하여 고정한 후 걷는 재활훈련을 시키는 로봇이며, 이것은”
Bodo, G., Tessari, F., Buccelli, S., & Laffranchi, M. (2024) · Applied Sciences · doi:10.3390/app14052017 · Cited by 6
Hou, Y., & Kiguchi, K. (2024) · IEEE Access · doi:10.1109/access.2024.3443545 · Cited by 5
“Threshold-based methods and machine learning approaches are applicable for detecting inappropriate motions of the user [18], [19], [20], [21], [22], [23], [48], [49], [50], [51], [52], [53], [54], [55].”
BackgroundMethodInfluentialA new approach for a Patient-Cooperative Upper Limb FES Support based on Vector Fields
Passon, A., Klewe, T., Seel, T., & Schauer, T. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1573 · Cited by 5
Ertop, T. E., Yuksel, T., & Konukseven, E. İ. (2018) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2018.02.012 · Cited by 6
Passon, A., Seel, T., Massmann, J., Freeman, C. T., & Schauer, T. (2018) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2018.8594120 · Cited by 5
“The major advantage of the applied approach, which had been inspired by previous work in rehabilitation robotics [16], [17], is that only the desired spatial movement trajectory 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) Madrid, Spain, October 1-5, 2018”
MethodOne-DOF Wire-Driven Robot Assisting Both Hip and Knee Flexion Motion
Miyake, T., Kobayashi, Y., Fujie, M. G., & Sugano, S. (2019) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2019.p0135 · Cited by 5
Development of a Novel Robotic Rehabilitation System With Muscle-to-Muscle Interface
Bong, J. H., Jung, S., Park, N., Kim, S., & Park, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00003 · Cited by 6
“A number of rehabilitation robots employ the well-known impedance control strategy for the active assist mode and the active resist mode to encourage active participation of the patient and to adjust the dynamic relationship between robot position and contact force (Emken and Reinkensmeyer, 2005; Agrawal et al., 2007;…”
BackgroundMethodA Unified Gait Phase Estimation and Control of Exoskeleton using Virtual Energy Regulator (VER)
Nasiri, R., Dinovitzer, H., & Arami, A. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896572 · Cited by 6
“The path-controller provides position and time tunnels over the designed path which gives the user some freedom in their voluntary motions and time-shift about the desired path timing [7], [12].”
BackgroundThree-Dimensional Multi-Degree-of-Freedom Arm Therapy Robot (ARMin)
Nef, T., Klamroth-Marganska, V., Keller, U., & Riener, R. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_27 · Cited by 6
Self-citationDesign of an 1 DOF Assistive Knee Joint for a Gait Rehabilitation Robot
Lee, S., Shin, S. Y., Lee, J., & Kim, C. (2013) · The Journal of Korea Robotics Society · doi:10.7746/jkros.2013.8.1.008 · Cited by 5
“로봇을 이용한 보행 재활에 가장 많이 사 용되고 있는 Lokomat (Hocoma AG, Switzerland)을 이용 하여 Alexander 등([8])은 Path Control 방법을 통해 보행 재 활이 필요한 환자와 로봇이 서로 상호작용을 하여 재활 효 과를 극대화하려는 연구가 진행되고 있다.”
BackgroundGuo, B., Han, J., Li, X., Wu, P., Zhang, Y., & You, A. (2017) · Advances in Mechanical Engineering · doi:10.1177/1687814017726293 · Cited by 5
Research on an assist-as-needed gait correction control strategy based on admittance control
Wu, J. Y., Guo, S., Yang, F., Wang, X., Sun, Q., & Sun, X. (2025) · Intelligent Service Robotics · doi:10.1007/s11370-025-00593-2 · Cited by 6
“The main idea of this controller is derived from the concept of a virtual tunnel proposed in [37].”
Design of high performance DC motor actuated cable driving system for compact devices
Direkwatana, C., & Suthakorn, J. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v11.i2.pp580-593 · Cited by 5
“In addition, the improvement in accuracy measurement by using load cell which has been shown in [56-59].”
MethodLower Extremity Exoskeleton for Human Spinal Cord Injury: A Comprehensive Review
Wang, T., Song, Z., Wen, H., & Liu, C. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3412809 · Cited by 6
Assist-as-Needed Robotic Strategy Based on Velocity Fields for Enhancing Motor Training
Garcia-Hernandez, N. V., Munguia-Angeles, C., & Parra‐Vega, V. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3445314 · Cited by 6
“To overcome the time constraint in trajectory-following tasks, there has been a proposed creation of a “moving window” (or free zone) along the ideal path [16], [17].”
T-S Fuzzy-Model-Based Tracking Control of Lower Limb Exoskeleton Rehabilitation Robot
Chen, M., Luo, X., Wang, X., Liu, H., & Mo, Y. (2024) · IEEE Conference on Cybernetics and Intelligent Systems · doi:10.1109/cis-ram61939.2024.10673013 · Cited by 4
“Compared with the traditional rehabilitation treatment, the use of lower limb exoskeleton rehabilitation robot can enhance patients' willingness to exercise actively, thereby improving the effect of rehabilitation training [2].”
BackgroundA Linear Rehabilitative Motion Planning Method with a Multi-Posture Lower-Limb Rehabilitation Robot
Wang, X., Lin, M., Sang, L., Wang, H., Feng, Y., Niu, J., Yu, H., & Cheng, B. H. (2024) · Sensors · doi:10.3390/s24237506 · Cited by 5
Miyake, T., Kobayashi, Y., Fujie, M. G., & Sugano, S. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009267 · Cited by 4
“reported that the application of robot assistance as needed encouraged maximum active patient participation [8].”
BackgroundDesigning Personalised Rehabilitation Controllers using Offline Model-Based Optimisation
Christou, A., Gordon, D., Stouraitis, T., & Vijayakumar, S. (2022) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio55434.2022.10011916 · Cited by 5
“[9] is used as an example surrogate controller.”
MethodDevelopment of a Compliant Lower-Limb Rehabilitation Robot Using Underactuated Mechanism
Yang, Y., Guo, J., Yao, Y., & Yin, H. (2023) · Electronics · doi:10.3390/electronics12163436 · Cited by 4
Review of Robot-Assisted Gait Rehabilitation after Stroke
Lv, X., & Wu, Z. (2013) · Journal of Rehabilitation Robotics · Cited by 7
Reference Trajectory Adaptation to Improve Human-Robot Interaction: A Database-Driven Approach
Haufe, F. L., Maggioni, S., & Melendez-Calderon, A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512604 · Cited by 5
“The proposed reference adaptation system combines the safety of prior, fixed reference approaches with the increased patient-cooperation found in more recent work[1, 2, 4, 11].”
Shin, S. Y., Kim, J., Lee, S., Lee, J., Kim, S., & Kim, C. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650498 · Cited by 4
Adaptive Patientenunterstützung für Rehabilitationsroboter
Duschau-Wicke, A., Morger, A., Vallery, H., & Riener, R. (2010) · at - Automatisierungstechnik · doi:10.1524/auto.2010.0836 · Cited by 7
“Die in [10] beschriebene Pfadregelung, die sich wie kürzlich demonstriert [11] ebenfalls als konservatives Kraftfeld implementieren und daher ideal mit dem in diesem Beitrag vorgestellten ILKK kombinieren lässt, ermöglicht eine solche räumlich Beschränkung, während sie gleichzeitig zeitlich freie Bewegungsabläufe erla…”
BackgroundSelf-citationMiyake, T., Kobayashi, Y., Fujie, M. G., & Sugano, S. (2018) · Mechanical Engineering Journal · doi:10.1299/mej.17-00660 · Cited by 4
“Assistance robots are designed for impaired (Duschau-Wicke et al., 2010; Esquenazi et al., 2012) and able-bodied (Collins et al., 2012; Mooney et al., 2014) people.”
BackgroundInfluentialPosition Based Impedance Control Strategy for a Lower Limb Rehabilitation Robot
Liang, X., Wang, W., Hou, Z., Ren, S., Wang, J., Shi, W., Peng, L., & Su, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857186 · Cited by 4
“The impedance control can be used to create a safe, comfortable and natural tactile interaction interface for the patient and improve the active compliance of the rehabilitation robot to avoid excessive confrontation between the mechanism and the human body and the risk of re-injury of the affected limb [9], [10].”
Qian, Y., Xiong, J., Yu, H., & Fu, C. (2026) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2026.3660874 · Cited by 7
“Compared to most AAN exoskeleton controls [14], [15], [16], [17], [18], [19], the proposed AAN control stimulated the subjects’ participation further by not following a predefined joint trajectory and only focused on minimizing the symmetry errors through as little assistance as possible, which…”
Optimizing Human–Exoskeleton Physical Interaction Through Spatial Trajectory Adaptation
Shushtari, M., Murray, L., Siavashani, A. G., & Arami, A. (2026) · IEEE Transactions on Robotics · doi:10.1109/tro.2026.3663979 · Cited by 4
“…strategy, particularly for users with partial impairments such as poststroke patients or individuals with incomplete spinal cord injury (iSCI), as the exoskeleton must encourage those to use their remaining motor capacity while providing the minimum required assistance for locomotion [3], [4], [5].”
A Bibliometric Analysis: The Application of Robotic Technology in Spine Surgery in the Past 30 Years
Zhou, Y., Ma, C., Wei, Z., & Kang, X. (2024) · Journal of Biomedical Research & Environmental Sciences · doi:10.37871/jbres1873 · Cited by 3
Preliminary Virtual Constraint-Based Control Evaluation on a Pediatric Lower-Limb Exoskeleton
Goo, A. C., Laubscher, C. A., Wajda, D. A., & Sawicki, J. T. (2024) · Bioengineering · doi:10.3390/bioengineering11060590 · Cited by 4
Metadata
- Authors
- Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R.
- Affiliations
- University of Zurich (CH)
- ORCID
- Riener, Robert
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-02
- Volume
- 18
- Issue
- 1
- Pages
- 38-48
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2147582248
- Semantic Scholar
- 636b7cc7f0480d0c421d94482805e1622e0ca1ff
- Cited by
- 421
- References
- 35
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 29 · 2023: 26 · 2022: 23 · 2021: 27 · 2020: 34 · 2019: 33 · 2018: 36 · 2017: 34 · 2016: 27 · 2015: 16 · 2014: 25 · 2013: 25 · 2012: 18
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.zora.uzh.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- National Institute on Disability and Rehabilitation Research (H133E070013)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- gait rehabilitation robot, path control, incomplete spinal cord injury, neurorehabilitation, gait timing, electromyography, gait kinematics, visual feedback, voluntary effort
- MeSH terms
- Humans, Leg, Male, Man-Machine Systems, Robotics, Therapy, Computer-Assisted, User-Computer Interface, Gait Disorders, Neurologic, Physical Therapy Modalities
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.