Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Gait rehabilitation robots are of increasing importance in neurorehabilitation. Conventional devices are often criticized because they are limited to reproducing predefined movement patterns. Research on patient-cooperative control strategies aims at improving robotic behavior. Robots should support patients only as much as needed and stimulate them to produce maximal voluntary efforts. This paper presents a patient-cooperative strategy that allows patients to influence the timing of their leg movements along a physiologically meaningful path. In this "path control" strategy, compliant virtual walls keep the patient's legs within a "tunnel" around the desired spatial path. Additional supportive torques enable patients to move along the path with reduced effort. Graphical feedback provides visual training instructions. The path control strategy was evaluated with 10 healthy subjects and 15 subjects with incomplete spinal cord injury. The spatio-temporal characteristics of recorded kinematic data showed that subjects walked with larger temporal variability with the new strategy. Electromyographic data indicated that subjects were training more actively. A majority of iSCI subjects was able to actively control their gait timing. Thus, the strategy allows patients to train walking while being helped rather than controlled by the robot.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and others have successfully been applied in rehabilitation, focusing also on limb and endeffector movements (Duschau-Wicke, von Zitewitz, Caprez, Lunenburger, & Riener, 2010;Holden & Dyar, 2002;Holden, Todorov, Callahan, & Bizzi, 1999).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
In the citing paper
“The haptic assist-as-needed strategy allows patients to control their movements, while still being provided sufficient guidance and support depending on the deviation from the target movement (Duschau-Wicke et al., 2010).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Nonparametric Statistical Inference
(2012) · SpringerReference · doi:10.1007/springerreference_205502 · Cited by 2,386
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Linear Mixed Models: A Practical Guide Using Statistical Software
West, B. T., Welch, K. B., & Gałecki, A. T. (2006) · Thammasat University Digital Collections · Cited by 1,382
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Self-citationRehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714
Pohl, M., Mehrholz, J., Ritschel, C., & Rückriem, S. (2002) · Stroke · doi:10.1161/hs0202.102365 · Cited by 508
Research works printed but not linked: 2
- von zitzewitz, 2006, path control: a new approach in patient-cooperative gait training with the rehabilitation robot lokomat, Joint Meet German Austrian Swiss Soc Biomed Eng
- hermens, 1999, European Recommendations for Surface Electromyography
Cited by
Items 301–400 of 424
Sun, J., Foroutani, Y., & Rosén, J. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3480157 · Cited by 3
“The restoring force can be generated by virtual springs [14], [15], spring damper systems [16], or viscoelastic couplings [17].”
Jung, C.-Y., Choi, J., Park, S., & Kim, S. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354174 · Cited by 4
“In [4] and [5], the patients were allowed to move their legs so that the trajectories in the joint space were deviated from the pre-defined nominal trajectory.”
BackgroundMiyake, T., Kobayashi, Y., Fujie, M. G., & Sugano, S. (2018) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2018.8664811 · Cited by 4
“The application of robot assistance as needed encourages maximum active patient participation [5].”
BackgroundImproving short-term retention after robotic training by leveraging fixed-gain controllers
Losey, D. P., Blumenschein, L. H., Clark, J. P., & O’Malley, M. K. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319866311 · Cited by 4
Design and Investigation on Control System of a Rehabilitation Robot Based on Walking Gait
Liu, Y., Zhang, L., Song, Q., Shuang, F., & Ge, Y. (2011) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-25541-0_38 · Cited by 3
“Gait rehabilitation training robot is a new robotic application in the medical field, and its main function is to help patient with lower limbs movement disorders complete the necessary health trainings and regain some of their prior functional abilities [4],[13],[14].”
Neckel, N. D., & Dai, H. (2021) · Behavioural Brain Research · doi:10.1016/j.bbr.2021.113415 · Cited by 3
Ergodic Shared Control: Closing the Loop on pHRI Based on Information Encoded in Motion
Fitzsimons, K., & Murphey, T. D. (2022) · ACM Transactions on Human-Robot Interaction · doi:10.1145/3526106 · Cited by 10
“Potential fields can limit the distance from the path [10, 33] or, in the case of error augmentation, push users away from the desired path.”
BackgroundXue, H., Michel, Y., & Lee, D. (2023) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-023-02023-w · Cited by 3
“Future work will also focus testing in comparison to control approaches not necessarily focused on DS, for example the path control paradigm [26].”
BackgroundDesign and Development of a Wearable Rehabilitation Robot
He, W., Ge, S. S., Guo, W., Zhao, Z., Zhang, J., Xiao, S., & Nuraisha, F. P. Q. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-34103-8_54 · Cited by 3
Preliminary results of force/torque sensorless impedance control for Walkbot
Tran, Q. V., Kim, S., Lee, K.-H., & Ryu, J. (2015) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2015.7358840 · Cited by 3
Tan, A. Q., & Dhaher, Y. Y. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318900 · Cited by 3
“A critical challenge to adaptive controller development is the incorporation of cooperative control algorithms that modulate the level of guidance according to the user’s intention [12].”
BackgroundDesign, Modeling, and Control of a Portable Leg Rehabilitation System
Goher, K. M., & Fadlallah, S. O. (2017) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4035815 · Cited by 3
Cognitive and Physiological Intent for the Adaptation of Motor Prostheses
Nataraj, R., Sanford, S., Liu, M., Walsh, K., Wilder, S., Santo, A., & Hollinger, D. S. (2020) · Springer eBooks · doi:10.1007/978-3-030-38740-2_8 · Cited by 4
Robot-Assisted Gait Training for Children and Youth with Cerebral Palsy
van Hedel, H. J. A., & Meyer‐Heim, A. (2020) · Springer eBooks · doi:10.1007/978-3-319-74558-9_172 · Cited by 3
Minkes-Weiland, S., Reinders‐Messelink, H. A., Boonstra, A. M., van der Woude, L. H. V., & den Otter, R. (2022) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.22.07539-6 · Cited by 5
Exoskeletal Robotics for Functional Substitution
Pons, J. L., Moreno, J. C., & Rocón, E. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch17 · Cited by 3
Fusing Electrical Stimulation and Wearable Robots with Humans to Restore and Enhance Mobility
Schauer, T., Fosch‐Villaronga, E., & Moreno, J. C. (2023) · Wiley eBooks · doi:10.1002/9781119857433.ch13 · Cited by 6
Zheng, Z., & Song, R. (2024) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm62033.2024.10715823 · Cited by 2
“As found in [20] [24], the increasing compliance may result in the increasing leg motion error.”
BackgroundOrhan, A., Hoàng, D., Bruneau, O., Berret, B., & Geffard, F. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3592058 · Cited by 2
“Although the absence of bio-information inevitably limits movement prediction capabilities, efficient and comfortable assistance have still been successfully achieved, especially in repetitive tasks when human movement demonstrations are available [13], [14], [16].”
Rahmani, K., Davoudi, M., Alamdar, M. S., & Nasiri, R. (2025) · Scientific Reports · doi:10.1038/s41598-025-10074-2 · Cited by 2
“…are derived from the gait parameters that were formerly introduced in the lower limb rehabilitation literature, such as gait path: knee-hip angle profile 51 , limit cycle: hip/knee velocity-angle profile 52 , and gait speed: Frobenius norm of hip-knee velocity as a function of gait cycle 53 .”
A Two-Layer Adaptive Assist-As-Needed Control Scheme for Rehabilitation Robotics
Zhang, M., Li, H., Shi, K., & Song, A. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3597481 · Cited by 5
“Similarly, controllers described in [11], [12], [13] define assistive torque profiles based on specific task requirements, providing corrective torques when the user’s motion deviates from the desired trajectory.”
Squat Training Assisted by a Rigid-Soft Hybrid Knee Exoskeleton: A Preliminary Study
Dai, X., Xu, M. Y., Zhong, H., Zhou, Z., Wang, R., Rong, X., Li, Y., & Wang, Q. (2025) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2025.3604140 · Cited by 3
“In the squatting phase, the exoskeleton follows an Assist-As-Needed (AAN) strategy, delivering force/torque support to the knee joint to compensate for the wearer’s physical disability [23].”
Zou, Y., Cheng, L., Yu, Z., Zhang, H., Han, L., Wang, Y., & Liu, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3029-1 · Cited by 2
“Recent studies have introduced impedance controllers that minimize intervention by establishing a torque-free zone around the reference path [15, 16].”
Li, S., Yang, Y., Cheng, S., Zhang, L., & Yu, H. (2026) · Expert Review of Medical Devices · doi:10.1080/17434440.2026.2640198 · Cited by 2
“Different from Banala, Duschau-Wicke [55] designed a torque field tunnel with adjustable width and shape in joint space and introduced a ‘moving window’ as front wall and back wall in virtual tunnel for effectively controlling the path of patient’s training.”
A novel approach for generalising walking gaits across embodiments and behaviours
Lin, H.-C., Howard, M., & Vijayakumar, S. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913912 · Cited by 3
Accurate Real-time Phase Estimation for Normal and Asymmetric Gait
Shushtari, M., Dinovitzer, H., Weng, J., & Arami, A. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896410 · Cited by 2
“In the active mode, the exoskeleton joints were controlled using an impedance controller with gait-phase dependent reference trajectory (similar to the Path Control method [11]) with the following joint stiffness (K) and damping (D) coefficients: KHip = 300 N.”
BackgroundMethodBeck, B. R. G., Tipper, J. L., & Su, S. W. (2022) · Australian & New Zealand Control Conference (ANZCC) · doi:10.1109/anzcc56036.2022.9966949 · Cited by 4
Model-Based Optimization for the Personalization of Robot-Assisted Gait Training
Christou, A., Gordon, D., Stouraitis, T., Moreno, J. C., & Vijayakumar, S. (2025) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2025.3550649 · Cited by 2
“This is expressed as [39]: Based on the true joint angle error, (cid:5) q , a proportional-derivative (PD) controller is used to ensure that assistive forces are provided by the exoskeleton in order to guide the user closer to the reference path.”
Hu, J. P., Hou, Z., Chen, Y., Peng, L., & Peng, L. (2013) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2013.6739767 · Cited by 4
“The common solution is to build an impedance free area around the predefined path for the spatial freedom where patients can move their injured limbs autonomously, but when they exceed outside, resistance occurs [9]–[13].”
BackgroundGrzechca, D. E., Ziębiński, A., Komorowski, D., Hanzel, K., Pokuciński, S., Klonowski, K., & Siwek, S. (2020) · Lecture notes in business information processing · doi:10.1007/978-3-030-44322-1_31 · Cited by 2
Neurorehabilitation robot system for neurological patients using H-infinity impedance controller
Kim, W., Lee, D., Yun, D., Ji, Y., Kang, M.-S., Han, J., & Han, C.-S. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281313 · Cited by 2
Adaptive trajectory control based robotic rehabilitation device
Anwar, T., & Al-Jumaily, A. A. (2014) · Middle East Conference on Biomedical Engineering · doi:10.1109/mecbme.2014.6783256 · Cited by 2
Eom, S.-H., & Lee, E.-H. (2016) · Technology and Health Care · doi:10.3233/thc-161188 · Cited by 2
Design of a compliant knee-motion actuator for lower extremity exoskeletons
Bai, K., Lee, K.-M., Lu, J., & Mi, Y. (2016) · IEEE International Conference on Advanced Intelligent Mechatronics (AIM) · doi:10.1109/aim.2016.7576840 · Cited by 2
“also restrict the force/torque manipulation which is the key for implementation of cooperative control strategies [17-18] between the wearer and the LEE.”
BackgroundMinimum Variance Estimation of Load-side External Torque Using Load-side Encoder and Torque Sensor
Yamada, S., & Fujimoto, H. (2018) · Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE) · doi:10.23919/sice.2018.8492670 · Cited by 2
“Also, cooperative robots are expected to be applied in humansupport fields to overcome aging society by reducing caregivers’ burden [2].”
BackgroundDesign and Control of a Novel Series Elastic Actuator for Knee Exoskeleton
Qian, C., Zhu, A., Song, J., Shen, H., Zhang, X., & Cao, G. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-27535-8_56 · Cited by 2
A Modified Patient-Cooperative Robot-Aided Gait Rehabilitation Algorithm Based on Path Control
Mahmoudi, A., & Najafi, F. (2019) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom48714.2019.9071862 · Cited by 2
“Where ?̃?sup (S) is the differentiation vector of the reference trajectory with respect to the relative position in the gait cycle, ksup is a scalar factor that determines the amount of support and according to [10] should be set to 5 to 7 (N.”
BackgroundMethodInfluentialvan Dellen, F., Aurich-Schuler, T., Hesse, N., & Labruyère, R. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01200-0 · Cited by 2
Motion-Assist Arm with a Passive Joint for an Upper Limb
KOZUKA, H., Uchijima, D., & TACHIYA, H. (2020) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2020.p0183 · Cited by 2
Lim, H. B. (2012) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/49512 · Cited by 2
Gait locomotion generation and leg muscle evaluation for overground walking rehabilitation robots
Wang, P. (2012) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/50714 · Cited by 2
“Furthermore, virtual force/velocity field control [87], path control [137] and virtual model control [92] are proposed for specified devices.”
Designing smart garments for rehabilitation
Wang, Q. (2018) · TU/e Research Portal · Cited by 3
Skill-Assist Arm Using Passive Joints to Aid Spatial Movement of Human Limbs
KOZUKA, H., & TACHIYA, H. (2024) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2024.3504291 · Cited by 1
“Devices assisting the path of the human limb have been previously developed [6], [7], [8], and many of them use impedance control [9].”
Assist-As-Needed Control of Soft Ankle Orthosis for Walking in Patients with Foot Drop
Sheikhi, P., Zareinejad, M., & Talebi, H. A. (2024) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom64545.2024.10903538 · Cited by 1
“The impedance controller’s design in general is analogous to that presented in [14].”
González-Mejía, S., & Ramírez-Scarpetta, J. M. (2025) · Tecnura · doi:10.14483/22487638.23473 · Cited by 1
“A state-of-the-art review of control strategies for robotic rehabilitation is presented in (59, 61) explains a patient-cooperative strategy that influences leg-movement synchronization along a physiological trajectory.”
Akıncı, M., Akıncı, M., Burak, M., Erturan, S., & Uzun, Ö. (2025) · İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi · doi:10.38079/igusabder.1644772 · Cited by 1
Yu, S., Fu, R., Ye, C., & Li, H. (2026) · Journal of Mechanisms and Robotics · doi:10.1115/1.4071421 · Cited by 1
Lower Extremity Flexible Assist Devices for Locomotion
Wu, M., & Landry, J. M. (2011) · Springer eBooks · doi:10.1007/978-1-4471-2277-7_20 · Cited by 2
A data-driven 3D vision feedback system for bilateral rehabilitation application
Xiang, K., Guo, S., & Zhibin, S. (2012) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2012.6285086 · Cited by 2
“Duschau-Wicke and et al [19] presented a patient-cooperative strategy by showing a compliant virtual wall on a screen.”
BackgroundModelling and control of a leg rehabilitation system for a reconfigurable wheelchair
Fadlallah, S. O., & Goher, K. (2013) · IEEE International Conference on Control System, Computing and Engineering · doi:10.1109/iccsce.2013.6719952 · Cited by 1
“[10] presented a patientcooperative strategy which allows patients to influence the timing of their leg movement along a meaningful path named Path Control method.”
BackgroundDevelopment of a robot-aided neuromuscular rehabilitation method using perturbing forces
Lee, S., & Kim, C. (2013) · IEEE International Symposium on Robotics (ISR) · doi:10.1109/isr.2013.6695681 · Cited by 1
Design of A Novel Gait Simulator for Rehabilitation Training
Liu, Y., Song, Q., Wang, B., Liu, Y., Nie, Y., Wang, H., & Shuang, F. (2013) · Cited by 1
Robot-Assisted Gait Training for Children and Youth with Cerebral Palsy
van Hedel, H. J. A., & Meyer‐Heim, A. (2019) · Springer eBooks · doi:10.1007/978-3-319-50592-3_172-1 · Cited by 1
An Assist-as-Needed Impedance Controller for Rehabilitation Robots
Asl, H. J., Yamashita, M., & Narikiyo, T. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-26118-4_11 · Cited by 1
Robotic Light Touch Assists Human Balance Control During Maximum Forward Reaching
Johannsen, L., Potwar, K., Saveriano, M., Endo, S., & Lee, D. (2020) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720820950534 · Cited by 1
Maddalena, M., & Saadat, M. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1890046 · Cited by 1
Severini, G., Koenig, A. C., Cajigas, I., Lesniewski-Laas, N., Niemi, J. B., & Bonato, P. (2023) · iScience · doi:10.1016/j.isci.2023.107038 · Cited by 2
Courtois, G., Dequidt, A., Chevrie, J., Bonnet, X., & Pudlo, P. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304696 · Cited by 1
“Currently the gait training consists mainly in reproducing a gait pattern commonly obtained based on mean gait data picked from healthy subjects [9], [10].”
BackgroundBodo, G., Giannattasio, R., Ramadoss, V., Tessari, F., & Laffranchi, M. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719791 · Cited by 1
“A significant amount of research in TIVeF controls is implemented in the joint domain [6], [10].”
BackgroundMethodNetwork-aware Shared Autonomy in Bilateral Teleoperation
Chen, X., Michel, Y., Sadeghian, H., & Haddadin, S. (2024) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids58906.2024.10769942 · Cited by 1
“Similar to [11], the force field is designed as a combination of the path [24] and flow control [25] laws, such that: To establish temporal independence within the force field, the desired position xxx d , s is determined as the closest point on the learned trajectory xxx d , a to the current…”
Wu, M., & Landry, J. M. (2016) · Springer eBooks · doi:10.1007/978-3-319-28603-7_21 · Cited by 1
Trajectory adaptation method for fast walking control of an exoskeleton
Lee, S., Seo, C., Choi, B., Kim, B., & Kim, S. (2017) · IEEE RO-MAN · doi:10.1109/roman.2017.8172439 · Cited by 1
“And because the arbitrary modification of the patient with impaired leg may lead an unphysiological gait pattern, the normal force along the trajectory was used to keep the limb move within a virtual wall [10].”
MethodExoskeletons Control via Computed Torque for Lower Limb Rehabilitation
Jribi, R., Maalej, B., & Derbel, N. (2020) · Studies in systems, decision and control · doi:10.1007/978-981-15-1819-5_7 · Cited by 1
Mogharabi, M., Esfahani, M. K., Tahamipour-Z., S. M., Akbarzadeh, A., & Kardan, I. (2021) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom54204.2021.9663442 · Cited by 1
Luu, T. P. (2014) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/58912 · Cited by 1
“To address those limitations mentioned above, subject-cooperative control strategies are being developed by many research groups [26, 27, 32-37, 39-43].”
BackgroundMethodInfluentialPérez‐Nombela, S., del‐Ama, A. J., Reyes-Guzmán, A. D. L., Gil-Agudo, A. M., Rueda, F. M., & Torricelli, D. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-34546-3_109
dos Santos, W. M. (2013) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.18.2013.tde-07112013-095345 · Cited by 2
Human-in-the-loop control during robot-assisted gait rehabilitation
Koenig, A. C. (2011) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-006483779
Miyake, T., Kobayashi, Y., Fujie, M. G., & Sugano, S. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844606
PREPARE A BIOLOID HUMANOID ROBOT TO COMPLETE THE TASKS OF THE CEABOT COMPETITION
Masiá, J., RUFINO, J. R., GILABERT, M., BENAVENT, A., & SANDOVAL, M. (2015) · ANNALS OF THE ORADEA UNIVERSITY Fascicle of Management and Technological Engineering · doi:10.15660/auofmte.2015-1.3119
Li, F., Wu, Z., & Qian, J. (2017) · International Journal of Control and Automation · doi:10.14257/ijca.2017.10.3.03
Design of adaptive regulator for lower extremity rehabilitation robot
Li, F., Hou, W., Qin, X., Wang, S., Zhang, X., & Liu, J. (2017) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2017.8015794
“It has been proved that task-oriented repetitive movements can improve muscular strength and movement coordination in patients with impairments resulting from neurological or orthopedic problems due to brain plasticity [1-3].”
BackgroundThe effects of gait retraining on muscle coordination and functional walking ability post-stroke
Srivastava, S. (2014) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/pdqt-aa13 · Cited by 2
Neuromuscular control of Lokomat guided gait: evaluation of training parameters
van Kammen, K. (2018) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Assessing the effect of walking with a linkage-based gait trainer by analysing muscle activation
Kora, K., Ward, S., & McDaid, A. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438736
“This ‘slacking’ effect has been found in some cases of robotic gait rehabilitation, where patients rely on the help of the device to move their legs [14].”
BackgroundControle de impedância adaptativo dirigido por EMG para reabilitacão robótica
Peña, G. G. (2017) · doi:10.11606/t.18.2019.tde-19032019-144320 · Cited by 2
TransforMe : exoskeleton for gait rehabilitation
Tutak, J. S., & Chmielewski, P. (2016) · Aparatura Badawcza i Dydaktyczna
Koopman, B. (2014) · doi:10.3990/1.9789036537667
“It is believed that, to promote neural plasticity, gait training should be task-specific, repetitive, meaningful, intensive, should start as soon as possible [40-53], and should provide appropriate afferent feedback [54].”
BackgroundMethodControl Algorithm of a Wearable Walking Robot for a Patient with Hemiplegia
Cho, C. (2020) · The Journal of Korea Robotics Society · doi:10.7746/jkros.2020.15.4.323
The Effect of Pelvic Movements of a Gait Training System for Stroke PatientsPreprint
Son, C., Lee, A., Lee, J., Kim, D., Kim, S., Chun, M. H., & Choi, J. (2021) · Research Square · doi:10.21203/rs.3.rs-254165/v1
Tanaka, T., Matsumura, R., Kato, N., & Hashimoto, N. (2021) · International Journal of New Technology and Research · doi:10.31871/ijntr.7.4.7
Evaluation of motor primitive-based adaptive control algorithms for lower limb exoskeletons
Nunes, P. F. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.18.2021.tde-02072021-124003
Changes in Muscle Activity with Assistance Level During Exoskeletal Gait in Acute StrokePreprint
O’Callaghan, B., Flood, M. W., Tonellato, M., Fingleton, C., Lowery, M. M., & Lennon, O. C. (2021) · Research Square · doi:10.21203/rs.3.rs-674617/v1 · Cited by 1
“In these tests, multiple comparisons were accounted for by Bonferroni adjustment as in (26,38) (αACC = 0.”
MethodWearable Lower Limb Exoskeletons for paraplegia: A Review
Kapula, P. R., Pasha, I. A., Kumar, B., & Sowmya, V. (2021) · International Conference on Technological Advancements and Innovations (ICTAI) · doi:10.1109/ictai53825.2021.9673413 · Cited by 1
Xie, S. Q. (2015) · Springer tracts in advanced robotics · doi:10.1007/978-3-319-19896-5_2
Ferrigno, G., Pedrocchi, A., Momi, E. D., Ambrosini, E., & Beretta, E. (2015) · CRC Press eBooks · doi:10.1201/b19147-3
Clinical Application of Rehabilitation Therapy Technologies to Children with CNS Damage
van Hedel, H. J. A., Aurich-Schuler, T., & Lieber, J. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_14
van Dellen, F., Aurich-Schuler, T., Hesse, N., & Labruyère, R. (2023) · Figshare · doi:10.6084/m9.figshare.23292068
Zhou, J., Sun, Y., Luo, L., Zhang, W., & Wei, Z. (2024) · Processes · doi:10.3390/pr12050924
González-Mejía, S., & Ramírez-Scarpetta, J. M. (2024) · Research Square · doi:10.21203/rs.3.rs-4602369/v1
Chen, L., Han, Y., Liu, C., Li, B., Huang, J., & Qiu, J. (2024) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm62033.2024.10715969
“[17], the posture correction module uses a radius w as the measurement standard to create a virtual tunnel around the reference trajectory.”
MethodShushtari, M., & Arami, A. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719865 · Cited by 1
“Their effectiveness relies heavily on their control strategy, particularly for users with partial impairments such as incomplete spinal cord injuries (iSCI), as the exoskeleton must encourage them to use their remaining motor capacity while providing just enough assistance for loco-motion [3], [4].”
BackgroundMethodA Novel Control Method of a 5-DOF Exoskeleton Robot for Post-Stroke Rehabilitation Training
Tong, L., Yang, F., Wang, C., & Peng, L. (2024) · International Convention on Rehabilitation Engineering & Assistive Technology · doi:10.1109/i-create62067.2024.10776214
Yoon, M.-H., Woo, B.-S., Park, Y.-H., Lee, D.-H., Kim, E.-S., Choi, J.-O., Lim, J.-H., Han, D.-S., & Yoon, T. (2024) · Physical Therapy Korea · doi:10.12674/ptk.2024.31.3.233
“These elements reflect the process by which stroke patients experience and resolve various movement patterns and errors through active engagement, and are closely associated with the plasticity of the central nervous system [26].”
Trigili, E., McKinney, Z., Crea, S., & Vitiello, N. (2025) · Springer eBooks · doi:10.1007/978-3-319-77270-7_6
Neckel, N. D. (2025) · Neurorehabilitation and neural repair · doi:10.1177/15459683251339809
Shahriari, E., Lachner, J., Haddadin, S., & Hogan, N. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3578848
“A diverse range of AAN policies has been proposed, spanning from tunnel-based methods with moving virtual walls [11], [12] to model-based adaptive controllers with a diminishing assisting force [13], [14], to methods incorporating reinforcement learning techniques [15], [16].”
Metadata
- Authors
- Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R.
- Affiliations
- University of Zurich (CH)
- ORCID
- Riener, Robert
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-02
- Volume
- 18
- Issue
- 1
- Pages
- 38-48
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2147582248
- Semantic Scholar
- 636b7cc7f0480d0c421d94482805e1622e0ca1ff
- Cited by
- 421
- References
- 35
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 29 · 2023: 26 · 2022: 23 · 2021: 27 · 2020: 34 · 2019: 33 · 2018: 36 · 2017: 34 · 2016: 27 · 2015: 16 · 2014: 25 · 2013: 25 · 2012: 18
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.zora.uzh.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- National Institute on Disability and Rehabilitation Research (H133E070013)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- gait rehabilitation robot, path control, incomplete spinal cord injury, neurorehabilitation, gait timing, electromyography, gait kinematics, visual feedback, voluntary effort
- MeSH terms
- Humans, Leg, Male, Man-Machine Systems, Robotics, Therapy, Computer-Assisted, User-Computer Interface, Gait Disorders, Neurologic, Physical Therapy Modalities
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.