Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Gait rehabilitation robots are of increasing importance in neurorehabilitation. Conventional devices are often criticized because they are limited to reproducing predefined movement patterns. Research on patient-cooperative control strategies aims at improving robotic behavior. Robots should support patients only as much as needed and stimulate them to produce maximal voluntary efforts. This paper presents a patient-cooperative strategy that allows patients to influence the timing of their leg movements along a physiologically meaningful path. In this "path control" strategy, compliant virtual walls keep the patient's legs within a "tunnel" around the desired spatial path. Additional supportive torques enable patients to move along the path with reduced effort. Graphical feedback provides visual training instructions. The path control strategy was evaluated with 10 healthy subjects and 15 subjects with incomplete spinal cord injury. The spatio-temporal characteristics of recorded kinematic data showed that subjects walked with larger temporal variability with the new strategy. Electromyographic data indicated that subjects were training more actively. A majority of iSCI subjects was able to actively control their gait timing. Thus, the strategy allows patients to train walking while being helped rather than controlled by the robot.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and others have successfully been applied in rehabilitation, focusing also on limb and endeffector movements (Duschau-Wicke, von Zitewitz, Caprez, Lunenburger, & Riener, 2010;Holden & Dyar, 2002;Holden, Todorov, Callahan, & Bizzi, 1999).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
In the citing paper
“The haptic assist-as-needed strategy allows patients to control their movements, while still being provided sufficient guidance and support depending on the deviation from the target movement (Duschau-Wicke et al., 2010).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Duschau-Wicke et al., 2010
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Nonparametric Statistical Inference
(2012) · SpringerReference · doi:10.1007/springerreference_205502 · Cited by 2,386
International Standards for Neurological and Functional Classification of Spinal Cord Injury
Maynard, F. M., Bracken, M. B., Creasey, G., Jr, J. F. D., Donovan, W. H., Ducker, T. B., Garber, S. L., Marino, R. J., Stover, S. L., Tator, C. H., et al. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100432 · Cited by 2,048
Linear Mixed Models: A Practical Guide Using Statistical Software
West, B. T., Welch, K. B., & Gałecki, A. T. (2006) · Thammasat University Digital Collections · Cited by 1,382
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,286
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Self-citationRehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714
Pohl, M., Mehrholz, J., Ritschel, C., & Rückriem, S. (2002) · Stroke · doi:10.1161/hs0202.102365 · Cited by 508
Research works printed but not linked: 2
- von zitzewitz, 2006, path control: a new approach in patient-cooperative gait training with the rehabilitation robot lokomat, Joint Meet German Austrian Swiss Soc Biomed Eng
- hermens, 1999, European Recommendations for Surface Electromyography
Cited by
Items 401–424 of 424
Masuya, K. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3592132
“Othermethodinvolves generatingavectorfieldbasedoncriteriasuchastheenergy field[10]ordistancefromthedesiredorbit[14],[15],[16], [17], [18], [19].”
Period Motion Tracking of Lower Limb Exoskeleton: A New Time-Independent Control Approach
Zhang, J., Shu, Z., & Xu, J. (2025) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2025.3610977
“For instance, Duschau-Wicke et al. [13] established the virtual tunnel around the reference signal in joint space in the control of the rehabilitation exoskeleton so that the patients can participate in walking more autonomously [14].”
3D Path Control: Can we use lower limb inter-joint coordination to assist gait and balance?
Orhan, Z. Ö., Ijspeert, A. J., & Bouri, M. (2025) · IEEE RO-MAN · doi:10.1109/ro-man63969.2025.11217626
“A key example is the ”Path Control” strategy introduced in [24], [25], which guides the user along a desired joint coordination pattern while allowing freedom in movement timing.”
Alingh, J. F., Fleerkotte, B. M., Groen, B. E., Rietman, J. S., Weerdesteyn, V., van Asseldonk, E. H. F., Geurts, A. C. H., & Buurke, J. H. (2021) · Figshare · doi:10.6084/m9.figshare.13725162
van Dellen, F., Aurich-Schuler, T., Hesse, N., & Labruyère, R. (2023) · Figshare · doi:10.6084/m9.figshare.23292065
Alingh, J. F., Fleerkotte, B. M., Groen, B. E., Rietman, J. S., Weerdesteyn, V., van Asseldonk, E. H. F., Geurts, A. C. H., & Buurke, J. H. (2021) · Figshare · doi:10.6084/m9.figshare.13725165
van Dellen, F., Aurich-Schuler, T., & Labruyère, R. (2024) · Figshare · doi:10.6084/m9.figshare.26598602
van Dellen, F., & Labruyère, R. (2022) · Figshare · doi:10.6084/m9.figshare.19642075
van Dellen, F., Aurich-Schuler, T., & Labruyère, R. (2024) · Figshare · doi:10.6084/m9.figshare.26598605
van Dellen, F., & Labruyère, R. (2022) · Figshare · doi:10.6084/m9.figshare.19642078
van Dellen, F., Aurich-Schuler, T., & Labruyère, R. (2024) · Figshare · doi:10.6084/m9.figshare.26598608
Li, X., & Yu, H. (2025) · Springer eBooks · doi:10.1007/978-981-96-9544-7_2
Zheng, Z., Wang, Y., Jian, C., Zhao, S., & Song, R. (2025) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm65671.2025.11293662 · Cited by 1
“…based on the capabilities of the users [19] [20] [21] ; Path-based controllers, by creating a “ virtual tunnel ” to restrict the range of motion of the paretic limb, prevent it from exceeding the boundaries, thus applying constraint forces to avoid inappropriate interjoint movement [22] [23] [24].”
Elstohy, M., & Gwak, K. (2026) · International Journal of Dynamics and Control · doi:10.1007/s40435-026-02026-z · Cited by 1
“Incorporating patient movement intention further boosts engagement and therapeutic efficacy [5, 6].”
Zhou, Z., Xu, H., Sun, Y., Ni, W., Ran, L., Hu, H., Zhang, X., & Liu, G. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3670526
“To date, control strategies can generally be divided into four categories: position tracking control [12], [13], [14], force and impedance control [15], [16], biosignal-based control [17], [18], and adaptive con-trol [19].”
Zhao, L., Zhu, C., Xie, Y., Wang, L., Luo, X., Lu, L., Ji, Y., Zeng, X., Wu, S., Huang, P., et al. (2026) · Digital Health · doi:10.1177/20552076261432283 · Cited by 1
Motion generation of four-limb robots using whole-body torque control
Du, W. (2020) · theses.fr (ABES) · doi:10.70675/4c032e31z5e88z4a0fzaeb9z22c05819b83a · Cited by 1
Alaoui, O. M. (2021) · theses.fr (ABES) · doi:10.70675/1eeb9e49zaae4z4fd0z83f3z1d176066fafc · Cited by 5
Control-enabled gait training with self-balanced lower-limb exoskeletons
Brunet, M. (2023) · theses.fr (ABES) · doi:10.70675/b4c3d9c6z480bz41b3zb292z1d24faf7cadd
Parallel Mechanism-Type Skill-Assist Arm Using a Passive-State Actuator to Aid Movement of Limbs
Tanaka, K., KOZUKA, H., & TACHIYA, H. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3685910
“In such devices, when the operator inputs a displacement in a direction deviating from the target trajectory, the arm generates a reactive force to return the output point to the trajectory [7], [8], [9].”
Gherle, A., Nistor-Cseppento, C. D., Cevei, M. L., Hodișan, R., & Lazăr, L. (2026) · Balneo and PRM Research Journal · doi:10.12680/balneo.2026.1014
Balance Assist During Walking With a Lower-Limb Power-Assist Robot Using Multiple Virtual Tunnels
Chen, J. Y., Nishikawa, S., & Kiguchi, K. (2026) · IEEE Access · doi:10.1109/access.2026.3726464
“Among such approaches, the concept of a ‘‘virtual tunnel’’ has been introduced in previous research [39], [40], [41], [42], where an allowable range of motion is defined by a set of thresholds along the ideal joint or task-space temporal trajectory, and inappropriate motion is identified when the…”
Li, H., Kou, J., Fu, X., Yang, Z., Shen, X., Sun, Z., Wang, Y., Shi, Y., Zhang, C., & Xie, F. (2026) · SmartSys · doi:10.1002/sys3.70040 · Cited by 1
Speed Regulation and Modulation in High-Gain Velocity-Field Control
Nasiri, R., Tang, L., Goldfarb, M., & Arami, A. (2026) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob66782.2026.11681089
“In 2009, Duschau-Wicke et al. [10] introduced an early AAN controller known as the path controller, which applies joint-level impedance towards the nearest joint configuration on a reference path when the deviation exceeds a defined channel threshold, allowing users to retain some gait variability…”
Metadata
- Authors
- Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R.
- Affiliations
- University of Zurich (CH)
- ORCID
- Riener, Robert
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-02
- Volume
- 18
- Issue
- 1
- Pages
- 38-48
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2147582248
- Cited by
- 421
- References
- 35
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 29 · 2023: 26 · 2022: 23 · 2021: 27 · 2020: 34 · 2019: 33 · 2018: 36 · 2017: 34 · 2016: 27 · 2015: 16 · 2014: 25 · 2013: 25 · 2012: 18
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- green
- www.zora.uzh.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- National Institute on Disability and Rehabilitation Research (H133E070013)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Keywords
- gait rehabilitation robot, path control, incomplete spinal cord injury, neurorehabilitation, gait timing, electromyography, gait kinematics, visual feedback, voluntary effort
- MeSH terms
- Humans, Leg, Male, Man-Machine Systems, Robotics, Therapy, Computer-Assisted, User-Computer Interface, Gait Disorders, Neurologic, Physical Therapy Modalities
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.