Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Control schemes for powered ankle-foot prostheses rely upon fixed torque-ankle state relationships obtained from measurements of intact humans walking at target speeds and across known terrains. Although effective at their intended gait speed and terrain, these controllers do not allow for adaptation to environmental disturbances such as speed transients and terrain variation. Here we present an adaptive muscle-reflex controller, based on simulation studies, that utilizes an ankle plantar flexor comprising a Hill-type muscle with a positive force feedback reflex. The model's parameters were fitted to match the human ankle's torque-angle profile as obtained from level-ground walking measurements of a weight and height-matched intact subject walking at 1 m/s. Using this single parameter set, clinical trials were conducted with a transtibial amputee walking on level ground, ramp ascent, and ramp descent conditions. During these trials, an adaptation of prosthetic ankle work was observed in response to ground slope variation, in a manner comparable to intact subjects, without the difficulties of explicit terrain sensing. Specifically, the energy provided by the prosthesis was directly correlated to the ground slope angle. This study highlights the importance of neuromuscular controllers for enhancing the adaptiveness of powered prosthetic devices across varied terrain surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Energy cost of walking of amputees: the influence of level of amputation.
Waters, R. L., Perry, J., Antonelli, D. J., & Hislop, H. J. (1976) · PubMed · Cited by 873
Energy cost of walking of amputees: the influence of level of amputation
Waters, R., Perry, J., Antonelli, D., & Hislop, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00007 · Cited by 842
Energetics of Actively Powered Locomotion Using the Simplest Walking Model
Kuo, A. D. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427703 · Cited by 736
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047592 · Cited by 627
Self-citationDesign and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Biomechanical Motor Patterns in Normal Walking
Winter, D. A. (1983) · Journal of Motor Behavior · doi:10.1080/00222895.1983.10735302 · Cited by 530
Biomechanics of below-knee amputee gait
Winter, D. A., & Sienko, S. E. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90142-x · Cited by 521
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“in both terrain [172] and gait speed [190] in a transtibial prosthesis.”
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“It is important to mention that classical and modern synthesis techniques have been recently used in the design and implementation of controllers for active hard robotic prosthetic systems [38, 41, 42, 48–50].”
MethodBiorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Self-citationJiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationQuintero, D., Villarreal, D. J., Lambert, D. J., Kapp, S., & Gregg, R. D. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2794536 · Cited by 252
“In order for the rigid ankle actuator to achieve compliant and forceful interaction with the ground [11], [43], [44], a uniaxial force sensor (Futek, LCM200) is installed inline with the ankle’s ball screw to provide feedback for a closed torque loop (Section III-B).”
Gregg, R. D., Lenzi, T., Hargrove, L. J., & Sensinger, J. W. (2014) · IEEE Transactions on Robotics · doi:10.1109/tro.2014.2361937 · Cited by 218
Estimation of Human Ankle Impedance During the Stance Phase of Walking
Rouse, E. J., Hargrove, L. J., Perreault, E. J., & Kuiken, T. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2307256 · Cited by 207
“Currently, the impedance of these devices is governed by sophisticated control systems that model muscle behavior [11], emulate user-specific spring and damper values [9], or use phase plane invariants [12].”
Simon, A. M., Ingraham, K. A., Fey, N. P., Finucane, S. B., Lipschutz, R. D., Young, A. J., & Hargrove, L. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099387 · Cited by 207
“Powered devices use a variety of control methods such as finite state machines in combination with an impedance-based model [7], artificial reflexes [8], or complementary motion estimation [9].”
BackgroundNeural Data-Driven Musculoskeletal Modeling for Personalized Neurorehabilitation Technologies
Sartori, M., Llyod, D. G., & Farina, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2538296 · Cited by 188
“In [156] and [157], a transtibial ankle prosthesis controller was developed based on a reflex-based neuromuscular model of the ankle joint muscles.”
MethodDesign and Validation of a Powered Knee–Ankle Prosthesis With High-Torque, Low-Impedance Actuators
Elery, T., Rezazadeh, S., Nesler, C., & Gregg, R. D. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2020.3005533 · Cited by 181
“This smooth transition paradigm can be considered as an extension of the methods proposed in [60] and [61], in which transition to stance is detected without contact sensing.”
MethodEstimation of Quasi-Stiffness and Propulsive Work of the Human Ankle in the Stance Phase of Walking
Shamaei, K., Sawicki, G. S., & Dollar, A. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059935 · Cited by 178
“Recently, researchers in the field of prosthetics and orthotics have moved toward quasi-passive systems and implemented impedance control methods in their designs [10,12,44,47].”
BackgroundSartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148
“Although online modelling was previously employed in 584 lower limb prostheses [50] and robotic exoskeleton [51,52] scenarios, our study proposes a paradigm never 585 presented for online myoelectric prosthesis control in transradial amputees.”
MethodA review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
The neuromechanics of animal locomotion: From biology to robotics and back
Ramdya, P., & Ijspeert, A. J. (2023) · Science Robotics · doi:10.1126/scirobotics.adg0279 · Cited by 92
“For instance, they were used to control an ankle prosthesis ( 57 , 58 ), an ankle-and-knee prosthesis ( 59 ), exoskeletons ( 60 ), and a simulated torque-controlled bipedal robot ( 61 ).”
MethodA Locomotion Intent Prediction System Based on Multi-Sensor Fusion
Chen, B., Zheng, E., & Wang, Q. (2014) · Sensors · doi:10.3390/s140712349 · Cited by 69
“Compared with passive lower-limb prostheses, powered prostheses can provide necessary power in certain periods to make the locomotion more natural, but they need more complex control strategies [7–12] and more locomotion information from amputees.”
Background
Metadata
- Authors
- Eilenberg, M. F., Geyer, H., & Herr, H.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-04
- Volume
- 18
- Issue
- 2
- Pages
- 164-173
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2147809815
- Cited by
- 419
- References
- 30
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.