Self-Paced Operation of an SSVEP-Based Orthosis With and Without an Imagery-Based “Brain Switch:” A Feasibility Study Towards a Hybrid BCI
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This work introduces a hybrid brain-computer interface (BCI) composed of an imagery-based brain switch and a steady-state visual evoked potential (SSVEP)-based BCI. The brain switch (event related synchronization (ERS)-based BCI) was used to activate the four-step SSVEP-based orthosis (via gazing at a 8 Hz LED to open and gazing at a 13 Hz LED to close) only when needed for control, and to deactivate the LEDs during resting periods. Only two EEG channels were required, one over the motor cortex and one over the visual cortex. As a basis for comparison, the orthosis was also operated without using the brain switch. Six subjects participated in this study. This combination of two BCIs operated with different mental strategies is one example of a "hybrid" BCI and revealed a much lower rate of FPs per minute during resting periods or breaks compared to the SSVEP BCI alone ( FP=1.46+/-1.18 versus 5.40 +/- 0.90). Four out of the six subjects succeeded in operating the self-paced hybrid BCI with a good performance (positive prediction value PPVb > 0.70).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“This means that both types of BCIs fulfill the requirements of a BCI, namely non-muscular control, extraction of specific brain signal features that reflect the user’s intent, real time processing and feedback [ 3 ].”
BackgroundMethodSelf-citationEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 4×
“…by flickering lights [5], by recognition of motor-related potentials [6], or by detection of the peri-imagery event-related desynchronization (ERD, [7]) and postimagery beta event related synchronization (ERS, [7] i.e., an increase (following a decrease) of spectral amplitudes of central beta…”
BackgroundInfluentialSelf-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“RAIN-COMPUTER interfaces (BCIs) are primarily developed for severely disabled people to improve their quality of life [ 1 ]–[4], but can also be used by healthy people to decrease their workload at the workspace, such as by providing a “third-hand.” Such a “third hand” can be used to press a button, switch on an appar…”
BackgroundDesign and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Brain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589
Self-citationNeuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317
Self-citationBeta rebound after different types of motor imagery in man
Pfurtscheller, G., Neuper, C., Brunner, C., & da Silva, F. L. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2004.12.034 · Cited by 302
Self-citationToward a hybrid brain–computer interface based on imagined movement and visual attention
Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026007 · Cited by 291
Self-citationKelly, S. P., Lalor, E. C., Reilly, R. B., & Foxe, J. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847369 · Cited by 233
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Self-citationA Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
“proposed a hybrid BCI, where an MI-based brain switch was used to turn ON/OFf an SSVEP-based BCI [25].”
MethodInfluentialProgress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Temporally Constrained Sparse Group Spatial Patterns for Motor Imagery BCI
Zhang, Y., Nam, C. S., Zhou, G., Jin, J., Wang, X., & Cichocki, A. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2841847 · Cited by 330
Brain–Computer Interfaces: A Gentle Introduction
Graimann, B., Allison, B., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_1 · Cited by 298
Self-citationLong, J., Li, Y., Wang, H., Yu, T., Pan, J., & Li, F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2197221 · Cited by 293
Toward a hybrid brain–computer interface based on imagined movement and visual attention
Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026007 · Cited by 291
Self-citationAn SSVEP BCI to Control a Hand Orthosis for Persons With Tetraplegia
Ortner, R., Allison, B. Z., Korisek, G., Gaggl, H., & Pfurtscheller, G. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2076364 · Cited by 281
Self-citationL1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“…feature set in order to enhance the performance or efficiency of the BCI system (Allison et al., 2010; Brunner et al., 2010; Li, Long, et al., 2010; Pfurtscheller et al., 2010; Rebsamen et al., 2010; Wei, Wang, Gao & Gao, 2007), whereas other studies used various kinds of features independently…”
ResultA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Simultaneous acquisition of EEG and NIRS during cognitive tasks for an open access dataset
Shin, J., von Lühmann, A., Kim, D.-W., Mehnert, J., Hwang, H.-J., & Müller, K.-R. (2018) · Scientific Data · doi:10.1038/sdata.2018.3 · Cited by 218
A Review of Hybrid Brain-Computer Interface Systems
Amiri, S., Fazel-Rezai, R., & Asadpour, V. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/187024 · Cited by 209
“In [16], one BCI (ERD) was used as a switch for another BCI (SSVEP) and the false positive rate was decreased for this sequential hybrid BCI.”
BackgroundMethodInfluentialMa, J., Zhang, Y., Cichocki, A., & Matsuno, F. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369483 · Cited by 209
“[17] [30] [31] [32] [33] ! !”
An Asynchronous P300 BCI With SSVEP-Based Control State Detection
Panicker, R. C., Puthusserypady, S., & Sun, Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116018 · Cited by 203
McMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A. D., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 188
“Two goals of hybrid BMIs are to decrease the number of false positives and to utilize a second input signal for natural control that complements the primary input modality.”
BackgroundInfluentialEEG feature comparison and classification of simple and compound limb motor imagery
Yi, W., Qiu, S., Qi, H., Zhang, L., Wan, B., & Ming, D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-106 · Cited by 183
“On the other hand, motor imagery has already been applied as a brain switch in a hybrid BCI system by detecting the postimagery beta event-related synchronization (ERS) of foot movement imagination to turn on/off a four-step electrically driven hand orthosis with two flickering lights in order to reduce the false posi…”
EEG-Based Control for Upper and Lower Limb Exoskeletons and Prostheses: A Systematic Review
AL-Quraishi, M. S., Elamvazuthi, I., Daud, S. A., Parasuraman, S., & Borboni, A. (2018) · Sensors · doi:10.3390/s18103342 · Cited by 164
“The BMI showed consistent performance with average true positive rate (TPR) = 62.7 ± 21.4% and 67.1 ± 14.6% on day ± 27.5 ± 35. ms before the closed-loop to carry out better performance across several days without system recalibration.”
BackgroundInfluentialLi, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“Multimodal BCIs combining MI and SSVEPs have also been reported [25], [26] and used in various applications, such as for controlling a cursor [26] or an orthosis [27].”
MethodInfluentialEnhancing brain-machine interface (BMI) control of a hand exoskeleton using electrooculography (EOG)
Witkowski, M., Cortese, M., Cempini, M., Mellinger, J., Vitiello, N., & Soekadar, S. R. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-165 · Cited by 83
“A possible strategy to increase safety of brain-controlled assistive systems in daily life environments is to use a switch mechanism turning the BMI system off or into sleep mode when active brain control is not needed or desired [7,8].”
BackgroundSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“As such, SSVEP BMIs have been applied to a broad range of applications including virtual spellers and such external devices as hand orthoses [85].”
BackgroundBenchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
“…a desired BCI command by looking at its corresponding part of the screen, and the BCI recognizes the command by measuring the dominant frequency of the visual cortex’s EEG activity (Middendorf et al., 2000; Gao et al., 2003; Pfurtscheller et al., 2010; Ortner et al., 2011; Sakurada et al., 2013).”
BackgroundGuo, M., Jin, J., Jiao, Y., Wang, X., & Cichockia, A. (2019) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2019.00024 · Cited by 18
“…(Pfurtscheller and Neuper, 2001; Wang et al., 2006; Hwang et al., 2009; Jiao et al., 2018), steady-state visual evoked potentials (SSVEP) BCI (Ortner et al., 2011; Jiao et al., 2016; Nakanishi et al., 2018; Zhang et al., 2018), hybrid BCI (Pfurtscheller et al., 2010; Li et al., 2016), and so on.”
Background
Metadata
- Authors
- Pfurtscheller, G., Solis-Escalante, T., Ortner, R., Linortner, P., & Muller-Putz, G. R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-08
- Volume
- 18
- Issue
- 4
- Pages
- 409-414
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2168138788
- Cited by
- 276
- References
- 21
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.