The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Simultaneous and Proportional Estimation of Hand Kinematics From EMG During Mirrored Movements at Multiple Degrees-of-Freedom
Open accessAbstract
This paper proposes and tests on able-bodied subjects a control strategy that can be practically applied in unilateral transradial amputees for simultaneous and proportional control of multiple degrees-of-freedom (DOFs). We used artificial neural networks to estimate kinematics of the complex wrist/hand from high-density surface electromyography (EMG) signals of the contralateral limb during mirrored bilateral movements in free space. The movements tested involved the concurrent activation of wrist flexion/extension, radial/ulnar deviation, forearm pronation/supination, and hand closing. The accuracy in estimation was in the range 79%-88% (r(2) index) for the four DOFs in six able-bodied subjects. Moreover, the estimation of the pronation/supination angle (wrist rotation) was influenced by the reduction in the number of EMG channels used for the estimation to a greater extent than the other DOFs. In conclusion, the proposed method and set-up provide a viable means for proportional and simultaneous control of multiple DOFs for hand prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for the solution of certain non-linear problems in least squares
Levenberg, K. (1944) · Quarterly of Applied Mathematics · doi:10.1090/qam/10666 · Cited by 12,359
Analysis of a complex of statistical variables into principal components.
Hotelling, H. (1933) · Journal of Educational Psychology · doi:10.1037/h0071325 · Cited by 9,633
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Analysis of a complex of statistical variables into principal components.
Hotelling, H. (1933) · Journal of Educational Psychology · doi:10.1037/h0070888 · Cited by 1,979
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
European recommendations for surface electromyography results of the SENIAM project
Hermens, H. J. (1999) · Cited by 581
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Self-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Self-citationLucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Self-citationHargrove, L. J., Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039590 · Cited by 219
Persistent hand motor commands in the amputees' brain
Reilly, K. T. (2006) · Brain · doi:10.1093/brain/awl154 · Cited by 175
Selective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 172
Hargrove, L. J., Losier, Y. G., Lock, B. A., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353424 · Cited by 170
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Fine detection of grasp force and posture by amputees via surface electromyography
Castellini, C., Gruppioni, E., Davalli, A., & Sandini, G. (2009) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2009.08.008 · Cited by 160
Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
Silcox, D. H., Rooks, M. D., Vogel, R., & Fleming, L. L. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199312000-00007 · Cited by 144
Electromyogram-based neural network control of transhumeral prostheses
Pulliam, C. L., Lambrecht, J. M., & Kirsch, R. F. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.12.0237 · Cited by 105
Sebelius, F., Eriksson, L., Balkenius, C., & Laurell, T. (2006) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331332546 · Cited by 59
High-density EMG E-Textile systems for the control of active prostheses
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627455 · Cited by 57
Self-citationEnhanced EMG signal processing for simultaneous and proportional myoelectric control
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. K. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332745 · Cited by 54
Self-citationMuceli, S., Jiang, N., & Farina, D. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627622 · Cited by 40
Self-citationFarina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 16
Self-citation
Cited by
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Self-citationSurface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Metadata
- Authors
- Muceli, S., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-05
- Volume
- 20
- Issue
- 3
- Pages
- 371-378
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1964025242
- Cited by
- 285
- References
- 32
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.