Simultaneous and Proportional Estimation of Hand Kinematics From EMG During Mirrored Movements at Multiple Degrees-of-Freedom
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
This paper proposes and tests on able-bodied subjects a control strategy that can be practically applied in unilateral transradial amputees for simultaneous and proportional control of multiple degrees-of-freedom (DOFs). We used artificial neural networks to estimate kinematics of the complex wrist/hand from high-density surface electromyography (EMG) signals of the contralateral limb during mirrored bilateral movements in free space. The movements tested involved the concurrent activation of wrist flexion/extension, radial/ulnar deviation, forearm pronation/supination, and hand closing. The accuracy in estimation was in the range 79%-88% (r(2) index) for the four DOFs in six able-bodied subjects. Moreover, the estimation of the pronation/supination angle (wrist rotation) was influenced by the reduction in the number of EMG channels used for the estimation to a greater extent than the other DOFs. In conclusion, the proposed method and set-up provide a viable means for proportional and simultaneous control of multiple DOFs for hand prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for the solution of certain non-linear problems in least squares
Levenberg, K. (1944) · Quarterly of Applied Mathematics · doi:10.1090/qam/10666 · Cited by 12,359
Analysis of a complex of statistical variables into principal components.
Hotelling, H. (1933) · Journal of Educational Psychology · doi:10.1037/h0071325 · Cited by 9,633
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Analysis of a complex of statistical variables into principal components.
Hotelling, H. (1933) · Journal of Educational Psychology · doi:10.1037/h0070888 · Cited by 1,979
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 3×
“In myoelectric control, not more than eight bipolar channels are usually employed as the source of control [4], [8], [10], [11].”
BackgroundElectromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 1×
“Regarding the processing time, it must be taken into account that some signal processing frameworks compensate for the reduced number of channels increasing the number of feature extracted from them [30], while the scheme that we proposed simply relies on the signal envelope [27], [31].”
European recommendations for surface electromyography results of the SENIAM project
Hermens, H. J. (1999) · Cited by 581
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Cited by
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
“Another group recorded angles of the controlateral hand with a camera system and used it for angle estimation [127].”
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Linear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365
Self-citationSurface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
“For the continuous task training phase, participants performed a bilateral mirrored behavioral task in which finger position from their intact hand and EMG data from their amputated limb were recorded (34).”
MethodJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Self-citationProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Self-citationIson, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“Muceli et al [49] compare this method with applying NMF on both DOF at once, noting that full simultaneous control can be obtained using three synergies instead of four when applying separately on each DOF.”
BackgroundMethodInfluentialIs Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218
“The efficacy of this scheme in realizing SPC has been now extensively demonstrated in able-bodied subjects [8], [10], as well as transradial amputees [9], [13], both in offline analysis [8]–[11], and in online validations [13].”
BackgroundResultSelf-citationHahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3630 · Cited by 216
Self-citationNgeo, J. G., Tamei, T., & Shibata, T. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-122 · Cited by 198
“Participants Similar to contemporary studies that proposed new EMGbased control strategies for hand control [5,7,11-13], healthy, able-bodied subjects participated in the experiments, which can be an initial basis before testing with disabled or amputated subjects.”
BackgroundResultStango, A., Negro, F., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2366752 · Cited by 191
“Recently, the use of high density (HD) EMG has been proposed as an input signal for prosthetic control [1], [3], supported by the improvement in grid electrode technology and by the development of more powerful microprocessors.”
BackgroundMethodSelf-citationSamuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“and proportional control of multiple DOFs joint movements to realize more intuitive and advanced control of artificial limbs [70]–[72].”
BackgroundAtzori, M., & Müller, H. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00162 · Cited by 183
“Supervised methods (Nielsen et al., 2011; Muceli and Farina, 2012; Ameri et al., 2014a,b; Gijsberts et al., 2014b; Hahne et al., 2014) are usually based on regression techniques (e.g., Linear Regression, LR, Artificial Neural Networks, ANN, Support Vector Machines, SVM) that require a reliable…”
MethodAn Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
“Muceli [24] proposed a proportional control strategy that could be practically applied in amputees for the real-time control of multiple degrees-of-freedom.”
BackgroundMuceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172
“Both linear [4] and nonlinear approaches [5], [6] have”
BackgroundSelf-citationMulti-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 172
“For most commercial myo-prosthetic hands, two electrode pairs on the extensor and the flexor respectively are usually adopted due to space limitations [27], power consumption [25], real-time performance [28], etc.”
BackgroundRegression convolutional neural network for improved simultaneous EMG control
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0e2e · Cited by 170
Advancing Muscle-Computer Interfaces with High-Density Electromyography
Amma, C., Krings, T., Böer, J., & Schultz, T. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702501 · Cited by 168
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“[109].”
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Lukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
“Low training times are frequently included in literature as a desired characteristic of prosthetic hand controllers [14, 21, 48].”
BackgroundUse of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
“…2014b, Smith et al., 2015a) and nonlinear (Jiang et al., 2012, Hahne et al., 2014, Kamavuako et al., 2012, Ameri et al., 2014, Ngeo et al., 2014, Muceli and Farina, 2012) methods of mapping EMG activity to prosthesis movement have been evaluated, though a large emphasis of real-time evaluation…”
MethodNeuroengineering: Deciphering neural drive
Ortiz-Catalan, M. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0034 · Cited by 13
Metadata
- Authors
- Muceli, S., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-05
- Volume
- 20
- Issue
- 3
- Pages
- 371-378
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W1964025242
- Cited by
- 285
- References
- 32
- FWCI
- 9.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.