The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A somatotopic bidirectional hand prosthesis with transcutaneous electrical nerve stimulation based sensory feedback
Open accessAbstract
According to amputees, sensory feedback is amongst the most important features lacking from commercial prostheses. Although restoration of touch by means of implantable neural interfaces has been achieved, these approaches require surgical interventions, and their long-term usability still needs to be fully investigated. Here, we developed a non-invasive alternative which maintains some of the advantages of invasive approaches, such as a somatotopic sensory restitution scheme. We used transcutaneous electrical nerve stimulation (TENS) to induce referred sensations to the phantom hand of amputees. These sensations were characterized in four amputees over two weeks. Although the induced sensation was often paresthesia, the location corresponded to parts of the innervation regions of the median and ulnar nerves, and electroencephalographic (EEG) recordings confirmed the presence of appropriate responses in relevant cortical areas. Using these sensations as feedback during bidirectional prosthesis control, the patients were able to perform several functional tasks that would not be possible otherwise, such as applying one of three levels of force on an external sensor. Performance during these tasks was high, suggesting that this approach could be a viable alternative to the more invasive solutions, offering a trade-off between the quality of the sensation, and the invasiveness of the intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Nonparametric statistical testing of EEG- and MEG-data
Maris, E., & Oostenveld, R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.024 · Cited by 8,496
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationA neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Muniak, M. A., Ray, S., Hsiao, S. S., Dammann, J. F., & Bensmaia, S. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1486-07.2007 · Cited by 235
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Research works printed but not linked: 40
- Engdahl, S. M. et al. Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques. Journal of neuroengineering and rehabilitation 12, 1 (2015). · DOI · Paper page
- Biddiss, E. A. & Chau, T. T. Upper limb prosthesis use and abandonment: a survey of the last 25 years. Prosthetics and orthotics international 31, 236–257 (2007). · DOI · Paper page
- Atkins, D. J., Heard, D. C. & Donovan, W. H. Epidemiologic overview of individuals with upper-limb loss and their reported research priorities. JPO: Journal of Prosthetics and Orthotics 8, 2–11 (1996).
- Antfolk, C. et al. Sensory feedback in upper limb prosthetics. Expert review of medical devices 10, 45–54 (2013). · DOI · Paper page
- Ehrsson, H. H. et al. Upper limb amputees can be induced to experience a rubber hand as their own. Brain 131(12), 3443–3452 (2008). · DOI · Paper page
- Kaczmarek, K. A., Webster, J. G., Bach-y Rita, P. & Tompkins, W. J. Electrotactile and vibrotactile displays for sensory substitution systems. IEEE Transactions on Biomedical Engineering 38, 1–16 (1991). · DOI · Paper page
- Davis, T. S. et al. Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves. Journal of neural engineering 13(3), 036001 (2016). · DOI · Paper page
- Farina, D. & Aszmann, O. Bionic limbs: clinical reality and academic promises. Science translational medicine 6, 257ps12–257ps12 (2014). · DOI
- Antfolk, C. et al. Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: vibrotactile versus mechanotactile sensory feedback. IEEE transactions on neural systems and rehabilitation engineering 21(no. 1), 12–120 (2013). · DOI · Paper page
- Chai, G., Sui, X., Li, S., He, L. & Lan, N. Characterization of evoked tactile sensation in forearm amputees with transcutaneous electrical nerve stimulation. Journal of Neural Engineering 12, 066002 (2015). · DOI
- Ramachandran, V. S. & Hirstein, W. The perception of phantom limbs. The DO Hebb lecture. Brain 121(no. 9), 1603–1630 (1998). · DOI · Paper page
- Ehrsson, H. H. et al. Upper limb amputees can be induced to experience a rubber hand as their own. Brain 131(no. 12), 3443–3452 (2008). · DOI · Paper page
- Witteveen, H. J., Luft, F., Rietman, J. S. & Veltink, P. H. Stiffness feedback for myoelectric forearm prostheses using vibrotactile stimulation. IEEE transactions on neural systems and rehabilitation engineering 22(no. 1), 53–61 (2014). · DOI
- Szeto, A. Y. & Saunders, F. A. Electrocutaneous stimulation for sensory communication in rehabilitation engineering. IEEE Transactions on Biomedical Engineering 4, 300–308 (1982). · DOI · Paper page
- Lundborg, G., Rosén, B. & Lindberg, S. Hearing as substitution for sensation: a new principle for artificial sensibility. The Journal of hand surgery 24(no. 2), 219–224 (1999). · DOI
- Chai, G. & Zhang, D. Developing Non-somatotopic Phantom Finger Sensation to Comparable Levels of Somatotopic Sensation through User Training with Electrotactile Stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering (2016). · DOI
- Sluka, K. A. & Walsh, D. Transcutaneous electrical nerve stimulation: basic science mechanisms and clinical effectiveness. The Journal of Pain 4, 109–121 (2003). · DOI · Paper page
- Anani, A. & Körner, L. Discrimination of phantom hand sensations elicited by afferent electrical nerve stimulation in below-elbow amputees. Medical progress through technology 6, 131–135 (1979).
- Kuhn, A., Keller, T., Lawrence, M. & Morari, M. A model for transcutaneous current stimulation: simulations and experiments. Medical & biological engineering & computing 47, 279–289 (2009). · DOI
- McNeal, D. R. Analysis of a model for excitation of myelinated nerve. IEEE Transactions on Biomedical Engineering 329–337 (1976). · DOI · Paper page
- Kaas, J. H., Merzenich, M. M. & Killackey, H. P. The reorganization of somatosensory cortex following peripheral nerve damage in adult and developing mammals. Annual review of neuroscience 6, 325–356 (1983). · DOI · Paper page
- Oddo, C. M. et al. Intraneural stimulation elicits discrimination of textural features by artificial fingertip in intact and amputee humans. Elife 5, e09148 (2016). · DOI · Paper page
- Nierula, B., Hohlefeld, F. U., Curio, G. & Nikulin, V. V. No somatotopy of sensorimotor alpha-oscillation responses to differential finger stimulation. Neuroimage 76, 294–303 (2013). · DOI
- Tamè, L., Braun, C., Holmes, N. P., Farnè, A. & Pavani, F. Bilateral representations of touch in the primary somatosensory cortex. Cognitive Neuropsychology 33, 1–19 (2016). · DOI
- Allison, T., McCarthy, G. & Wood, C. C. The relationship between human long-latency somatosensory evoked potentials recorded from the cortical surface and from the scalp. Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section 84, 301–314 (1992). · DOI · Paper page
- Genna, C. et al. Spatiotemporal Dynamics of the Cortical Responses Induced by a Prolonged Tactile Stimulation of the Human Fingertips, Brain Topography, 1–13 (2017). · DOI
- Zhang, D., Xu, F., Xu, H., Shull, P. B. & Zhu, X. Quantifying different tactile sensations evoked by cutaneous electrical stimulation using electroencephalography features. International journal of neural systems 26(no. 02), 1650006 (2016). · DOI
- Farrell, T. R. & Weir, R. F. The optimal controller delay for myoelectric prostheses. IEEE Transactions on neural systems and rehabilitation engineering 15, 111–118 (2007). · DOI · Paper page
- Dosen, S. et al. Multichannel Electrotactile Feedback with Spatial and Mixed Coding for Closed-Loop Control of Grasping Force in Hand Prostheses. IEEE Transactions on Neural Systems and Rehabilitation Engineering (2016). · DOI
- Dosen, S., Ninu, A., Yakimovich, T., Dietl, H. & Farina, D. A novel method to generate amplitude-frequency modulated vibrotactile stimulation. IEEE transactions on haptics 9, 3–12 (2016). · DOI
- Oostenveld, R. & Praamstra, P. The five percent electrode system for high-resolution eeg and erp measurements. Clinical neurophysiology 112, 713–719 (2001). · DOI · Paper page
- Artoni, F., Menicucci, D., Delorme, A., Makeig, S. & Micera, S. Relica: a method for estimating the reliability of independent components. NeuroImage 103, 391–400 (2014). · DOI
- Artoni, F. et al. ErpICASSO: a tool for reliability estimates of independent components in EEG event-related analysis. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 368–371 IEEE, (2012). · DOI
- Artoni, F., Chisari, C., Menicucci, D., Fanciullacci, C. & Micera, S. Remov: Eeg artifacts removal methods during lokomat lower-limb rehabilitation. 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), 992–997 (IEEE, 2012). · DOI
- Sebastiani, L., Castellani, E., Gemignani, A., Artoni, F. & Menicucci, D. Inefficient stimulus processing at encoding affects formation of high-order general representation: A study on cross-modal word-stem completion task. Brain research 1622, 386–396 (2015). · doi:10.1016/j.brainres.2015.06.042
- Makeig, S., Bell, A. J., Jung, T. P. & Sejnowski, T. J. Independent component analysis of electroencephalographic data. Advances in neural information processing systems 145–151 (1996).
- Menicucci, D. et al. Brain responses to emotional stimuli during breath holding and hypoxia: An approach based on the independent component analysis. Brain topography 27(6), 771–785 (2014). · DOI
- Makeig, S. et al. Electroencephalographic brain dynamics following manually responded visual targets. PLoS Biol 2(6), e176 (2004). · DOI · Paper page
- Scheeringa, R. et al. Neuronal dynamics underlying high-and low-frequency EEG oscillations contribute independently to the human BOLD signal. Neuron 69(3), 572–583 (2011). · DOI · Paper page
- Dosen, S., Schaeffer, M.-C. & Farina, D. Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback. Journal of neuroengineering and rehabilitation 11, 1 (2014). · DOI
Cited by
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Self-citationToward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationRestoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Self-citation
Metadata
- Authors
- D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S.
- Venue
- Scientific Reports
- Published
- 2017-09-07
- Volume
- 7
- Issue
- 1
- Pages
- 10930-10930
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2751515399
- Cited by
- 215
- References
- 13
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A somatotopic bidirectional hand prosthesis with transcutaneous electrical nerve stimulation based sensory feedback. https://app.cochat.ai/papers/10.1038/s41598-017-11306-w
- The paper
- D’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017). A somatotopic bidirectional hand prosthesis with transcutaneous electrical nerve stimulation based sensory feedback. Scientific Reports. https://doi.org/10.1038/s41598-017-11306-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.