The DOI matches its Crossref record; 36 of the 39 references it cites were found in a registry or an index.
Non-Invasive, Temporally Discrete Feedback of Object Contact and Release Improves Grasp Control of Closed-Loop Myoelectric Transradial Prostheses
Abstract
Human grasping and manipulation control critically depends on tactile feedback. Without this feedback, the ability for fine control of a prosthesis is limited in upper limb amputees. Although various approaches have been investigated in the past, at present there is no commercially available device able to restore tactile feedback in upper limb amputees. Based on the Discrete Event-driven Sensory feedback Control (DESC) policy we present a device able to deliver short-lasting vibrotactile feedback to transradial amputees using commercially available myoelectric hands. The device (DESC-glove) comprises sensorized thimbles to be placed on the prosthesis digits, a battery-powered electronic board, and vibrating units embedded in an arm-cuff being transiently activated when the prosthesis makes and breaks contact with objects. The consequences of using the DESC-glove were evaluated in a longitudinal study. Five transradial amputees were equipped with the device for one month at home. Through a simple test proposed here for the first time-the virtual eggs test-we demonstrate the effectiveness of the device for prosthetic control in daily life conditions. In the future the device could be easily exploited as an add-on to complement myoelectric prostheses or even embedded in prosthetic sockets to enhance their control by upper limb amputees.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Lost functions were restored to the patients with central nervous system damages by electrically activating the intact tissues distal to neural lesions.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Clemente et al., 2016
Citations
Cites
Adult Norms for the Box and Block Test of Manual Dexterity
Mathiowetz, V. G., Volland, G., Kashman, N., & Weber, K. (1985) · American Journal of Occupational Therapy · doi:10.5014/ajot.39.6.386 · Cited by 2,105
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Upper limb prosthesis use and abandonment
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics and Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,123
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 734
Keating, C. (1983) · American Journal of Occupational Therapy · doi:10.5014/ajot.37.9.636 · Cited by 690
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 587
Research works printed but not linked: 3
- radomski, 2008, Occupational Therapy for Physical Dysfunction
- solomonow, 1978, Fundamentals of electrotactile stimulation for sensory feedback from limb prosthetics, Adv Ext Control Human Extr, 409
- johansson, 1993, Predictive feed-forward sensory control during grasping and manipulation in man, Biomedical Research-Tokyo, 14, 95
Cited by
Sorted by citations
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 355
Self-citationA closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Self-citationA Review of Sensory Feedback in Upper-Limb Prostheses From the Perspective of Human Motor Control
Sensinger, J. W., & Dosen, S. S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00345 · Cited by 253
Metadata
- Authors
- Clemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C.
- Affiliations
- Scuola Superiore Sant'Anna (IT)
- Umeå University (SE)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2016-12
- Volume
- 24
- Issue
- 12
- Pages
- 1314-1322
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2344461637
- Cited by
- 209
- References
- 39
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 21 · 2023: 25 · 2022: 28 · 2021: 32 · 2020: 24 · 2019: 27 · 2018: 19 · 2017: 7 · 2016: 5
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- Seventh Framework Programme (FP7-ICT-288551)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- vibrotactile feedback, transradial amputation, myoelectric prosthesis, grasp control, upper limb amputees
- MeSH terms
- Amputees, Artificial Limbs, Electromyography, Hand, Humans, Prosthesis Design, Radius, Robotics, Task Performance and Analysis, Touch, Vibration, Wrist Joint, Gloves, Protective, Hand Strength, Equipment Failure Analysis, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review