Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
To understand the effects of soft exosuits on human loaded walking, we developed a reconfigurable multi-joint actuation platform that can provide synchronized forces to the ankle and hip joints. Two different assistive strategies were evaluated on eight subjects walking on a treadmill at a speed of 1.25 m/s with a 23.8 kg backpack: 1) hip extension assistance and 2) multi-joint assistance (hip extension, ankle plantarflexion and hip flexion). Results show that the exosuit introduces minimum changes to kinematics and reduces biological joint moments. A reduction trend in muscular activity was observed for both conditions. On average, the exosuit reduced the metabolic cost of walking by 0.21 ±0.04 and 0.67 ±0.09 W/kg for hip extension assistance and multi-joint assistance respectively, which is equivalent to an average metabolic reduction of 4.6% and 14.6%, demonstrating that soft exosuits can effectively improve human walking efficiency during load carriage without affecting natural walking gait. Moreover, it indicates that actuating multiple joints with soft exosuits provides a significant benefit to muscular activity and metabolic cost compared to actuating single joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066 · cited 1×
“) using a 75-marker full-body protocol [41], [42].”
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“) using a 75-marker full-body protocol [41], [42].”
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“L OWER-LIMB wearable robots have been proposed as a means to augment or assist human locomotion for many applications [1].”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280 · cited 1×
“There have also been a few studies with various research platforms that have looked at the effects of applying torques at the hip on various biomechanical and physiological variables [16], [36]–[38].”
BackgroundEsquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“Some wearable robots have been designed to augment the locomotion performance of able-bodied individuals through enabling wearers to spend less energy or carry an increased load [2]–[6], while others have been designed to enable individuals to walk if they were not able to previously [7]–[9], or supplement rehabilitat…”
BackgroundBiomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777 · cited 1×
“While these are impressive achievements, the rigid nature of existing exoskeletons presents a number of challenges towards the goal of enhancing or restoring locomotion: 1) they may interfere with joint movement due to misalignment between the robot and biological joints and thus cause the wearer to deviate from their…”
BackgroundAdaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
The mechanics and energetics of human walking and running: a joint level perspective
Farris, D. J., & Sawicki, G. S. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0182 · Cited by 546 · cited 1×
“The rationale for exploring these joints is that they have been shown to be the largest energetic contributors to forward propulsion during human locomotion [40] and our ultimate goal is to create systems that can reduce the metabolic consumption for the wearer.”
Background
Cited by
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Self-citationHuman-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
Self-citationAssistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Self-citationA biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Self-citationEffect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
“ters the mechanics of non-assisted joints, thus favorably tuning the musculoskeletal system as a whole [6, 9, 28] rather than acting on a specific muscle group.”
InfluentialSelf-citationSoft Robotic Suits: State of the Art, Core Technologies, and Open Challenges
Xiloyannis, M., Alicea, R., Georgarakis, A.-M., Haufe, F. L., Wolf, P., Masia, L., & Riener, R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3084466 · Cited by 225
“[143], [53] and mobile [55], [52], [139] devices.”
BackgroundCompliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
“12) Weight Bearing: Weight bearing is the fourth most covered motor skill, with 19 publications, [9], [20], [34], [51], [53], [73], [128], [130], [146], [149], [153], [160], [164], [172], [179]–[184].”
Thalman, C., & Artemiadis, P. (2020) · Wearable Technologies · doi:10.1017/wtc.2020.4 · Cited by 186
Design and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance
Shepherd, M. K., & Rouse, E. J. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2704521 · Cited by 174
“Despite a rich history in powered lower-limb exoskeletons [8]–[10], there are no suitable devices on the market to perform the proposed research.”
BackgroundSoft, Wearable Robotics and Haptics: Technologies, Trends, and Emerging Applications
Zhu, M., Biswas, S., Dinulescu, S. I., Kastor, N., Hawkes, E. W., & Visell, Y. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2021.3140049 · Cited by 172
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Self-citationPhysiological and kinematic effects of a soft exosuit on arm movements
Xiloyannis, M., Chiaradia, D., Frisoli, A., & Masia, L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0495-y · Cited by 161
Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
Kim, J., Quinlivan, B. T., Deprey, L.-A., Arumukhom Revi, D., Eckert-Erdheim, A., Murphy, P., Orzel, D., & Walsh, C. J. (2022) · Scientific Reports · doi:10.1038/s41598-022-14784-9 · Cited by 91
Self-citationO’Brien, K. W., Xu, A., Levine, D. J., Aubin, C. A., Yang, H.-J., Xiao, M. F., Wiesner, L. W., & Shepherd, R. F. (2018) · Science Robotics · doi:10.1126/scirobotics.aau5543 · Cited by 71
Metadata
- Authors
- Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-02
- Volume
- 25
- Issue
- 2
- Pages
- 119-130
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2344043336
- Cited by
- 217
- References
- 47
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.