Wearable Assistive Tactile Communication Interface Based on Integrated Touch Sensors and Actuators
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This paper presents the design and fabrication of a wearable tactile communication interface with vibrotactile feedback for assistive communication. The interface is based on finger Braille, which is a simple and efficient tactile communication method used by deafblind people. It consists of a flexible piezoresistive sensor and a vibrotactile actuator integrated together and positioned at the index, middle and ring fingers of both hands to represent the six dots of Braille. The sensors were made using flexible piezoresistive material whereas the actuator utilizes electromagnetic principle by means of a flexible coil and a tiny NdFeB permanent magnet. Both were integrated to realize a Bluetooth-enabled tactile communication glove which enables deafblind people to communicate using Braille codes. The evaluation with 20 end-users (10 deafblind and 10 sighted and hearing person) of the tactile interface under standardized conditions demonstrated that users can feel and distinguish the vibration at frequencies ranging from 10Hz to 200Hz which is within the perceivable frequency range for the FA-II receptors. The results show that it took non-experts in Braille within 25s and 55s to send and receive words like "BEST" and "JOURNAL", with an accuracy of ~75% and 68% respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tactile spatial resolution in blind Braille readers
Boven, R. W. V., Hamilton, R. H., Kauffman, T., Keenan, J. P., & Pascual–Leone, A. (2000) · Neurology · doi:10.1212/wnl.54.12.2230 · Cited by 380
A closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Large-Area Soft e-Skin: The Challenges Beyond Sensor Designs
Dahiya, R., Yogeswaran, N., Liu, F., Manjakkal, L., Burdet, E., Hayward, V., & Jörntell, H. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2941366 · Cited by 309
Self-citationBeyond sensory substitution—learning the sixth sense
Nagel, S. K., Carl, C., Kringe, T., Märtin, R., & König, P. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r02 · Cited by 225 · cited 1×
“Over the past decade, many devices have been developed for the purpose of sensory substitution for various assistive purposes [11], [12].”
BackgroundNanowire FET Based Neural Element for Robotic Tactile Sensing Skin
Taube Navaraj, W., García Núñez, C., Shakthivel, D., Vinciguerra, V., Labeau, F., Gregory, D. H., & Dahiya, R. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00501 · Cited by 127
Self-citationProviding a sense of touch to prosthetic hands
Nghiem, B. T., Sando, I. C., Gillespie, R. B., McLaughlin, B. L., Gerling, G. J., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2015) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0000000000001289 · Cited by 104 · cited 2×
“5(d)), the resonant frequency of the actuator is around 40Hz which is enough to stimulate the Pacinian Corpuscle of the human skin [42].”
Background
Cited by
Neuro-inspired electronic skin for robots
Liu, F., Deswal, S., Christou, A., Sandamirskaya, Y., Kaboli, M., & Dahiya, R. (2022) · Science Robotics · doi:10.1126/scirobotics.abl7344 · Cited by 300
Self-citationToward immersive communications in 6G
Shen, X. (., Gao, J., Li, M., Zhou, C., Hu, S., He, M., & Zhuang, W. (2023) · Frontiers in Computer Science · doi:10.3389/fcomp.2022.1068478 · Cited by 124
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“The transduction principle that have potentially been used in these types of sensors are based on these e ff ects: piezoelectric, piezocapacitive, piezoresistive, and triboelectric [131].”
MethodPillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Recent Advances in Artificial Intelligence and Wearable Sensors in Healthcare Delivery
Junaid, S. B., Imam, A. A., Abdulkarim, M., Surakat, Y. A., Balogun, A. O., Kumar, G., Shuaibu, A. N., Garba, A., Sahalu, Y., Mohammed, A., et al. (2022) · Applied Sciences · doi:10.3390/app122010271 · Cited by 65
Metadata
- Authors
- Ozioko, O., Karipoth, P., Hersh, M., & Dahiya, R.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2020-06
- Volume
- 28
- Issue
- 6
- Pages
- 1344-1352
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W3020333500
- Cited by
- 103
- References
- 6
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Assistive Tactile Communication Interface Based on Integrated Touch Sensors and Actuators. https://app.cochat.ai/papers/10.1109/tnsre.2020.2986222
- The paper
- Ozioko, O., Karipoth, P., Hersh, M., & Dahiya, R. (2020). Wearable Assistive Tactile Communication Interface Based on Integrated Touch Sensors and Actuators. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2020.2986222
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.