Three-Port Triple-Half-Bridge Bidirectional Converter With Zero-Voltage Switching
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A three-port triple-half-bridge bidirectional dc-dc converter topology is proposed in this paper. The topology comprises a high-frequency three-winding transformer and three half-bridges, one of which is a boost half-bridge interfacing a power port with a wide operating voltage. The three half-bridges are coupled by the transformer, thereby providing galvanic isolation for all the power ports. The converter is controlled by phase shift, which achieves the primary power flow control, in combination with pulsewidth modulation (PWM). Because of the particular structure of the boost half-bridge, voltage variations at the port can be compensated for by operating the boost half-bridge, together with the other two half-bridges, at an appropriate duty cycle to keep a constant voltage across the half-bridge. The resulting waveforms applied to the transformer windings are asymmetrical due to the automatic volt-seconds balancing of the half-bridges. With the PWM control it is possible to reduce the rms loss and to extend the zero-voltage switching operating range to the entire phase shift region. A fuel cell and supercapacitor generation system is presented as an embodiment of the proposed multiport topology. The theoretical considerations are verified by simulation and with experimental results from a 1 kW prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782 · cited 3×
“However, the turn-off currents of and are not equal because the boost half-bridge is not symmetrical [19].”
BackgroundInfluentialFamily of multiport bidirectional DC–DC converters
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20050362 · Cited by 488
Self-citationTransformer-Coupled Multiport ZVS Bidirectional DC–DC Converter With Wide Input Range
Tao, H., Kotsopoulos, A., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915129 · Cited by 478
Self-citationThree-Port Bidirectional Converter for Hybrid Fuel Cell Systems
Duarte, J. L., Hendrix, M., & Simoes, M. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889928 · Cited by 441
Self-citationCharacteristics of the Multiple-Input DC–DC Converter
Matsuo, H., Lin, W., Kurokawa, F., Shigemizu, T., & Watanabe, N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825362 · Cited by 385
Multi-input DC/DC converter based on the multiwinding transformer for renewable energy applications
Chen, Y.-M., Liu, Y.-C., & Wu, F.-Y. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800776 · Cited by 350
A PWM Plus Phase-Shift Control Bidirectional DC–DC Converter
Xu, D., Zhao, C., & Fan, H. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.826485 · Cited by 284
A ZVS Bi-Directional DC–DC Converter for Multiple Energy Storage Elements
Liu, D., & Li, H. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.882450 · Cited by 283
New DC–DC converter for energy storage system interfacing in fuel cell hybrid electric vehicles
Marchesoni, M., & Vacca, C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886650 · Cited by 263 · cited 1×
“Furthermore, a three-switch boost converter is proposed in [11].”
Background
Cited by
Overview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Pwm control of dual active bridge: Comprehensive analysis and experimental verification
Jain, A. K., & Ayyanar, R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2070519 · Cited by 567
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Falcones, S., Ayyanar, R., & Mao, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215965 · Cited by 501
Oggier, G. G., Garcia, G. O., & Oliva, A. R. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2072966 · Cited by 498
Krishnaswami, H., & Mohan, N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022756 · Cited by 411
Nejabatkhah, F., Danyali, S., Hosseini, S. H., Sabahi, M., & Niapour, S. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172465 · Cited by 406
A Review of Power Electronics for Grid Connection of Utility-Scale Battery Energy Storage Systems
Wang, G., Konstantinou, G., Townsend, C. D., Pou, J., Vazquez, S., Demetriades, G. D., & Agelidis, V. G. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2586941 · Cited by 362
A High Step-Up Three-Port DC–DC Converter for Stand-Alone PV/Battery Power Systems
Chen, Y.-M., Huang, A. Q., & Yu, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242491 · Cited by 305
Topology Derivation of Nonisolated Three-Port DC–DC Converters From DIC and DOC
Wu, H., Sun, K., Ding, S., & Xing, Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2221746 · Cited by 298
Zhou, H., & Khambadkone, A. M. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2023493 · Cited by 283
Identification of Feasible Topologies for Multiple-Input DC–DC Converters
Kwasinski, A. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2009538 · Cited by 267
Multiport Power Electronic Interface—Concept, Modeling, and Design
Jiang, W., & Fahimi, B. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2093583 · Cited by 259
Weise, N. D., Castelino, G., Basu, K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293112 · Cited by 223
“PSM, DPS, and SHBM are studied in the context of multiport converters in [32].”
Shi, Y., Li, R., Xue, Y., & Li, H. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2411858 · Cited by 194
Topology Analysis and Review of Three-Port DC–DC Converters
Wang, Z., Luo, Q., Wei, Y., Mou, D., Lu, X., & Sun, P. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2985287 · Cited by 192
Affam, A., Buswig, Y. M., Othman, A.-K. B. H., Julai, N. B., & Qays, O. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110186 · Cited by 192
Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
“DT-ATAB offers an admirable efficiency as compared to the existing isolated MPCs [7], [8] and can be a promising tool for the high-power multisource power applications.”
BackgroundNovel Modular Multiple-Input Bidirectional DC–DC Power Converter (MIPC) for HEV/FCV Application
Hintz, A., Prasanna, U. R., & Rajashekara, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2371778 · Cited by 158
“A similar operation is proposed with a halfbridge circuit at each source in [18] using half the number of switches and supplementary capacitors.”
MethodRashidi, M., Altin, N. N., Ozdemir, S. S., Bani-Ahmed, A., & Nasiri, A. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2939741 · Cited by 90
“Therefore, in some studies, the duty cycle control is applied along with the phase-shift control to improve the system control [11], [17], [25].”
BackgroundMinimum-RMS-current operation of asymmetric dual active half-bridge converters with and without ZVS
Chakraborty, S., & Chattopadhyay, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2613874 · Cited by 72
“Researchers have also proposed use of asymmetric duty-ratio control to minimise rms current and improve ZVS performance of the boost-integrated/ current-fed DAHB converter [7] by rendering a trapezoidal or flat-topped profile to the transformer current waveform [9], [10], [17], [18].”
MethodModelling and ZVS control of an isolated three-phase bidirectional AC-DC converter
Jauch, F., & Biela, J. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634323 · Cited by 19
“First, the converter topology including the applied high-frequency transformer is presented.”
Method
Metadata
- Authors
- Tao, H., Duarte, J. L., & Hendrix, M. A. M.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-03
- Volume
- 23
- Issue
- 2
- Pages
- 782-792
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2129374939
- Cited by
- 404
- References
- 19
- FWCI
- 19.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.