Small-Signal Methods for AC Distributed Power Systems–A Review
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
AC distributed power systems (DPS) can be found in several new and emerging applications. Similar to dc distributed power systems, an ac DPS relies on power electronics and control to realize its functions and achieve the required performance. System stability and power quality are important issues in both types of systems due to the complex system behavior resulted from active control at both the source and the load side. Traditional small-signal analysis methods cannot be directly applied to an ac DPS because of the periodically time-varying system operation trajectory. Possible solutions to this problem include transformation into a rotating (dq) reference frame, modeling using dynamic phasors, reduced-order modeling, and harmonic linearization. This paper reviews these small-signal methods and discusses their utilities as well as limitations. Compatibility of each type of models with state-space and impedance-based system analysis approaches will also be discussed. Problems related to the linearization of phasor-based models and their use in impedance-based system analysis are highlighted in particular.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Analysis of Electric Machinery and Drive Systems
(2013) · Wiley eBooks · doi:10.1002/9781118524336 · Cited by 2,678
Hatziargyriou, N., Asano, H., Iravani, R., & Marnay, C. (2007) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2007.376583 · Cited by 2,519
Analysis of Electric Machinery and Drive Systems
Krause, P. C., Wasynczuk, O., & Sudhoff, S. D. (2002) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544167 · Cited by 2,314
Power system voltage stability
Taylor, C. W. (1993) · Medical Entomology and Zoology · Cited by 2,157
Vector Control and Dynamics of AC Drives
Novotny, D. W., & Lipo, T. A. (1996) · doi:10.1093/oso/9780198564393.001.0001 · Cited by 1,841
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644 · cited 1×
“AC DPS is a relatively new development, but is being used in several new and emerging applications such as more-electric and all-electric aircraft [5], [6], electric ships [7], [8], renewable energy and distributed generation [9], microgrid [10], and smart grid [ 11 ].”
BackgroundGeneralized averaging method for power conversion circuits
Sanders, S. R., Noworolski, J. M., Liu, X. Z., & Verghese, G. C. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.76811 · Cited by 1,205
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
On the use of averaging for the analysis of power electronic systems
Krein, P. T., Bentsman, J., Bass, R. M., & Lesieutre, B. L. (1990) · IEEE Transactions on Power Electronics · doi:10.1109/63.53155 · Cited by 589
Cited by
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Self-citationAnalysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Self-citationModeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785
Microgrid Stability Definitions, Analysis, and Examples
Farrokhabadi, M., Canizares, C. A., Simpson-Porco, J. W., Nasr, E., Fan, L., Mendoza-Araya, P. A., Tonkoski, R., Tamrakar, U., Hatziargyriou, N., Lagos, D., et al. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2925703 · Cited by 752
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2378731 · Cited by 453
An Active Damper for Stabilizing Power-Electronics-Based AC Systems
Wang, X., Blaabjerg, F., Liserre, M., Chen, Z., He, J., & Li, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2278716 · Cited by 367
Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network
Miao, Z. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2012.2211019 · Cited by 329
Liu, H., Xie, X., Zhang, C., Li, Y., Liu, H., & Hu, Y. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2558840 · Cited by 327
Sequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
Self-citationFrequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“of the d–q impedance-based stability analysis is that it can only detect whether the system is stable or not, but cannot determine the stability margin [27].”
BackgroundZhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2811718 · Cited by 262
Hoffmann, N., & Fuchs, F. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2259507 · Cited by 248
“Besides the network distortions, a nonnegligible grid impedance is an important parameter that determines the interaction between distributed energy sources (and loads) among each other [5]–[7] and that determines the stability limits of the whole electrical power system [3], [8], [9].”
BackgroundVoltage Stability and Control of Offshore Wind Farms With AC Collection and HVDC Transmission
Liu, H., & Sun, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2361290 · Cited by 245
“By applying proper modeling method, such as harmonic linearization [9], impedance models valid both below and above the fundamental frequency can be developed, thereby overcoming the other lim-”
MethodSelf-citationLyu, J., Cai, X., & Molinas, M. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2759096 · Cited by 194
“According to the harmonic linearization principle [20], by injecting a small sinusoidal perturbation voltage in the ac side of MMC (as shown in Fig.”
MethodImpedance-Based Stability and Transient-Performance Assessment Applying Maximum Peak Criteria
Vesti, S., Suntio, T., Oliver, J. A., Prieto, R., & Cobos, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2220157 · Cited by 180
“Although the discussions in this letter are limited to the conventional voltage-fed (VF) converters, the presented ideas and discussions are equally valid for different applications when the minor-loop gain and the relevant impedances are correctly defined as discussed in [13]—[15], [22], and [23].”
BackgroundRobust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Conceptualization and Multiobjective Optimization of the Electric System of an Airborne Wind Turbine
Kolar, J. W., Friedli, T., Krismer, F., Looser, A., Schweizer, M., Friedemann, R. A., Steimer, P. K., & Bevirt, J. B. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2269672 · Cited by 74
“Furthermore, there exist close couplings of this subject to current questions in the area of More Electric Aircraft [12] and Smart Grids [13]—the power electronics system of the AWT can be regarded as a Smart Pico Grid— or in general to the multiobjective optimization of converter systems [14], [15].”
Impedance modeling of modular multilevel converters by harmonic linearization
Lyu, J., Chen, Q., & Cai, X. (2016) · 2016 IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL) · doi:10.1109/compel.2016.7556719 · Cited by 20
Metadata
- Authors
- Sun, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2009-11
- Volume
- 24
- Issue
- 11
- Pages
- 2545-2554
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2160410553
- Cited by
- 712
- References
- 16
- FWCI
- 22.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.