The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Research on voltage and power balance control for cascaded modular solid-state transformer
Abstract
The solid-state transformer (SST) is one of the key elements in power electronic-based microgrid systems. The single-phase SST consists of a modular multilevel ac-dc rectifier, a modular dual active bridge (DAB) dc-dc converter with high-frequency transformers, and a dc-ac inverter stage. However, due to dc bus voltage and power unbalancing in each module, the modular SST often presents instability problems making its design difficult and causing unpredictable behavior. Moreover, the unbalanced dc-link voltages increase the stress of the semiconductor devices, and also cause high harmonic distortions of grid current, therefore, necessitating the use of a bigger ac filter. This paper presents a novel single-phase d-q vector-based common-duty-ratio control method for the multilevel rectifier, and a voltage feedforward and feedback based controller for the modular DAB converter. With the proposed control methods, the dc-link voltage and power in each module can be balanced. In addition, the low-distortion grid current, unity power factor, and bidirectional power flow can be achieved. Simulation and experimental results are presented to validate the proposed control methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665
Multilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Multilevel converters for large electric drives
Tolbert, L. M., Peng, F. Z., & Habetler, T. G. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.740843 · Cited by 1,408
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Switching Control Strategy to Minimize Dual Active Bridge Converter Losses
Oggier, G. G., GarcÍa, G. O., & Oliva, A. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2020902 · Cited by 514
Recent developments of high power converters for industry and traction applications
Bernet, S. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.892825 · Cited by 458
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Voltage and Power Balance Control for a Cascaded H-Bridge Converter-Based Solid-State Transformer
Zhao, T., Wang, G., Bhattacharya, S., & Huang, A. Q. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2216549 · Cited by 642
“One of the main disadvantages of the cascaded H-bridge rectifier is the voltage unbalance of the dc-link voltages at different H-Bridges [5]–[7], [12], [13], [18], [20].”
BackgroundSelf-citationGeneralized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Zhao, B., Song, Q., & Liu, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2189586 · Cited by 406
Hybrid ac/dc microgrids—Part I: Review and classification of topologies
Unamuno, E., & Barrena, J. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.194 · Cited by 399
Zhao, B., Song, Q., & Liu, W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2210563 · Cited by 325
Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application
She, X., Yu, X., Wang, F., & Huang, A. Q. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293471 · Cited by 324
Self-citationWang, L., Zhang, D., Wang, Y., Wu, B., & Athab, H. S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2450756 · Cited by 285
Gu, C., Zheng, Z., Xu, L., Wang, K., & Li, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2416212 · Cited by 221
Circulating Current and ZVS-on of a Dual Active Bridge DC-DC Converter: A Review
Shao, S., Chen, H., Wu, X., Zhang, J., & Sheng, K. (2019) · IEEE Access · doi:10.1109/access.2019.2911009 · Cited by 200
“SSTs based on DABs in power grids have been introduced to interconnect different scale micro-grids [6], [10], [11] or to connect different level of dc grids [12]–[17].”
BackgroundZhao, B., Song, Q., & Liu, W. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2350459 · Cited by 143
Abu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
“circulating cu rents [56] and voltage unbalance [57] between parallel MMCs and Hbridge modules compromise the reli bility and cause voltage stress.”
BackgroundKrishnamoorthy, H. S., Rana, D., Garg, P., Enjeti, P. N., & Pitel, I. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295419 · Cited by 48
Hybrid-Frequency Cascaded Full-Bridge Solid-State Transformer
Zhang, X., Xu, Y., Long, Y., Xu, S., & Siddique, A. (2019) · IEEE Access · doi:10.1109/access.2019.2898985 · Cited by 45
“Besides, the HF-link power balancing control [21] is also omitted thus simplifies the control system.”
BackgroundNew Bidirectional Intelligent Semiconductor Transformer for Smart Grid Application
Han, B.-M., Choi, N.-S., & Lee, J.-Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2284009 · Cited by 37
Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies
Wang, X., Liu, J., Ouyang, S., & Meng, F. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2331701 · Cited by 37
“In [17], [18], and [28], different control strategies are proposed for the same single-”
BackgroundA Single-Stage Isolated Resonant SiC DC/AC Inverter for Efficient High-Power Applications
Tayebi, S. M., Xu, W., Wang, H., Yu, R., Guo, Z., & Huang, A. Q. (2020) · 2020 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec39645.2020.9124343 · Cited by 26
Self-citationZhao, H., Zhu, T., Cheng, D., Li, B., Ding, J., & Li, Y. (2017) · The Journal of Engineering · doi:10.1049/joe.2017.0656 · Cited by 19
A novel multi-port solid state transformer enabled isolated hybrid microgrid architecture
Nair, A. C., & Fernandes, B. G. (2017) · IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2017.8216113 · Cited by 15
She, X., Huang, A. Q., & Ni, X. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6646725 · Cited by 14
“In [6], a common duty ratio controller for the cascaded multilevel rectifier stage in the single phase d-q coordinate and feedback feed-forward controller for the DC/DC stage are proposed.”
BackgroundMethodSelf-citationOperation of a three phase solid state-Transformer under unbalanced load conditions
Venkat, J., Shukla, A., & Kulkarni, S. V. (2014) · 2014 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES) · doi:10.1109/pedes.2014.7042116 · Cited by 12
A Simple Control Method without Voltage Balance Algorithm for Modular Solid-State Transformer
Jang, P., Park, H.-P., Baek, J., Kim, D.-U., & Kim, S. (2022) · 2022 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9948182 · Cited by 4
Itoh, J.-I., Aoyagi, K., & Nakanishi, T. (2017) · 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017 - ECCE Asia) · doi:10.1109/ifeec.2017.7992060 · Cited by 3
“Furthermore, in the conventional SST, a bulky capacitor at the DC link with a large capacitance is required in order to maintain the constant capacitor voltage in each cell [12-13].”
Background
Metadata
- Authors
- Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2011-04
- Volume
- 26
- Issue
- 4
- Pages
- 1154-1166
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2172181625
- Cited by
- 362
- References
- 28
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.