An Islanding Microgrid Power Sharing Approach Using Enhanced Virtual Impedance Control Scheme
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
In order to address the load sharing problem in islanding microgrids, this paper proposes an enhanced distributed generation (DG) unit virtual impedance control approach. The proposed method can realize accurate regulation of DG unit equivalent impedance at both fundamental and selected harmonic frequencies. In contrast to conventional virtual impedance control methods, where only a line current feed-forward term is added to the DG voltage reference, the proposed virtual impedance at fundamental and harmonic frequencies is regulated using DG line current and point of common coupling (PCC) voltage feed-forward terms, respectively. With this modification, the impacts of mismatched physical feeder impedances are compensated. Thus, better reactive and harmonic power sharing can be realized. Additionally, this paper also demonstrates that PCC harmonic voltages can be mitigated by reducing the magnitude of DG unit equivalent harmonic impedance. Finally, in order to alleviate the computing load at DG unit local controller, this paper further exploits the band-pass capability of conventionally resonant controllers. With the implementation of proposed resonant controller, accurate power sharing and PCC harmonic voltage compensation are achieved without using any fundamental and harmonic components extractions. Experimental results from a scaled single-phase microgrid prototype are provided to validate the feasibility of the proposed virtual impedance control approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 2×
“When the microgrid is disconnected from the utility grid to form an autonomous islanding system, the droop control method can be applied to realize decentralized power sharing among DG units [3]–[17], [27]–[29].”
BackgroundMethodSelf-citationPower-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Self-citationA Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Self-citationLi, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Self-citationGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Self-citationRobust Droop Controller for Accurate Proportional Load Sharing Among Inverters Operated in Parallel
Zhong, Q.-C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2146221 · Cited by 890
Cited by
Liu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Self-citationOverview of Power Management Strategies of Hybrid AC/DC Microgrid
Nejabatkhah, F., & Li, Y. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2384999 · Cited by 986
Self-citationHou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Self-citationA Review on Microgrids’ Challenges & Perspectives
Saeed, M. H., Fangzong, W., Kalwar, B. A., & Iqbal, S. (2021) · IEEE Access · doi:10.1109/access.2021.3135083 · Cited by 539
Accurate Reactive Power Sharing in an Islanded Microgrid Using Adaptive Virtual Impedances
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2314721 · Cited by 453
Zhang, H., Kim, S., Sun, Q., & Zhou, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2506760 · Cited by 315
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Self-citationDistributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Serban, I., & Marinescu, C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2283298 · Cited by 274
Zhou, J., Kim, S., Zhang, H., Sun, Q., & Han, R. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2613143 · Cited by 209
“virtual impedance adjustment using PCC voltage has been introduced [34], where a microgrid central controller shall be required.”
BackgroundMethodImpedance Circuit Model of Grid-Forming Inverter: Visualizing Control Algorithms as Circuit Elements
Li, Y., Gu, Y., Zhu, Y., Junyent-Ferre, A., Xiang, X., & Green, T. C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3015158 · Cited by 207
Self-citationHigh-Fidelity Model Order Reduction for Microgrids Stability Assessment
Vorobev, P., Huang, P.-H., Al Hosani, M., Kirtley, J. L., & Turitsyn, K. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2707400 · Cited by 205
“Thus, several research works have proposed the concept of virtual impedances, virtual inductances or virtual synchronous generators [16], [17], [34], [35].”
BackgroundOverview of AC Microgrid Controls with Inverter-Interfaced Generations
Hossain, M., Pota, H., Issa, W., & Hossain, M. (2017) · Energies · doi:10.3390/en10091300 · Cited by 205
“Therefore, harmonic virtual impedance is proposed in [101].”
A Fault Clearing Method in Converter-Dominated Microgrids With Conventional Protection Means
Oureilidis, K. O., & Demoulias, C. S. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2476702 · Cited by 199
“2, in order to minimize the circulating currents among the connected DERs [27], [28].”
BackgroundTah, A., & Das, D. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2535264 · Cited by 191
Reactive Power Sharing in Islanded Microgrids Using Adaptive Voltage Droop Control
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2399232 · Cited by 185
Mohammed, N., Udawatte, H., Zhou, W., Hill, D. J., & Bahrani, B. (2024) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2024.3371985 · Cited by 183
Decentralized Power Management of a PV/Battery Hybrid Unit in a Droop-Controlled Islanded Microgrid
Mahmood, H., Michaelson, D., & Jiang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2394351 · Cited by 169
Feng, W., Jin, M., Liu, X., Bao, Y., Marnay, C., Yao, C., & Yu, J. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.06.096 · Cited by 168
“, adjustable load sharing method [80] and adaptive droop control [81].”
MethodLi, Z., Zang, C., Zeng, P., Yu, H., & Li, S. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2749424 · Cited by 166
A Virtual Impedance Optimization Method for Reactive Power Sharing in Networked Microgrid
Zhu, Y., Zhuo, F., Wang, F., Liu, B., Gou, R., & Zhao, Y. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2450360 · Cited by 159
Flexible Grid Connection and Islanding of SPC-Based PV Power Converters
Rodriguez, P., Citro, C., Candela, J. I., Rocabert, J., & Luna, A. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2800683 · Cited by 126
Robust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Multi-Microgrid Transmission Control for a Lunar Surface Power System
Carbone, M. A., Muscatello, M. J., Follo, J. C., Fernandez, X. C., & Csank, J. T. (2023) · 2023 IEEE Aerospace Conference · doi:10.1109/aero55745.2023.10116002 · Cited by 5
Metadata
- Authors
- He, J., Li, Y. W., Guerrero, J. M., Blaabjerg, F., & Vasquez, J. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-11
- Volume
- 28
- Issue
- 11
- Pages
- 5272-5282
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1978592021
- Cited by
- 482
- References
- 25
- FWCI
- 54.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.