Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In this paper, a new technique for stator winding interturn fault detection in current-controlled permanent magnet synchronous machines is proposed. The method is based on online extraction of the second harmonic component of the voltage reference vector in the dq frame. It will be shown that the amplitude of this harmonic depends on the interturn fault severity and the fault detection is realized by comparing the magnitude of the control voltage second harmonic, derived using a proper time-domain transformation, to a predefined threshold. This is a low-cost method in CPU burden time. The experimental results show the validity of the proposed method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is shown that the ITSC introduces the 2 nd order harmonic signal into the d-q rotating reference frame (they correspond to the third-order harmonics in A-B-C frame; the classical Park transform reduces the order of the harmonic by one).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“Thus, searching for some characteristic frequencies in the components of the reference voltage vector have been proposed in [52].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“Finally, filtered components create a vector whose amplitude becomes a fault indictor.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“The authors propose to transform the d-q frame voltage signals into a new frame rotating with three times the synchronous speed.In this frame the fault-related signals are constant in time and can be filtered by a low pass filter.Therefore, there is no need to apply the FFT on-line.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 1×
“Well-known tools like fast Fourier transform and Wigner–Ville Distribution are applied for this purpose [18]–[20].”
MethodEL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373 · cited 2×
“So, they are well adapted for transportation applications either for propulsion or other equipments [2].”
BackgroundAdvances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 2×
“It is well known that the stator winding faults are among the most spread failures in ac machines [9]–[11].”
BackgroundRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 1×
“An efficient way to improve the availability of a drive is to detect its faults in real time in order to switch to a degraded operating mode under fault conditions [5].”
BackgroundGrubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490 · cited 1×
“Because of the closeness of the spires belonging to the same phase, it is admitted that the first appearing faults are often turnto-turn [12]–[14].”
BackgroundModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282 · cited 1×
“This model is close to those presented in [29] and [30].”
MethodApplication of AI tools in fault diagnosis of electrical machines and drives-an overview
Awadallah, M. A., & Morcos, M. M. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811739 · Cited by 220 · cited 1×
“Otherwise, the fault current grows up rapidly with the fault severity and may cause fire or lead to mechanical failures [26].”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214 · cited 1×
“Well-known tools like fast Fourier transform and Wigner–Ville Distribution are applied for this purpose [18]–[20].”
MethodEbrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Control Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
“It is well known that the stator winding faults are the most prevalent failures in ac machine, where the interturn fault is one of the most common stator winding faults [6].”
BackgroundZafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“In [91], the second harmonics in the reference d–q voltage v∗ d and v∗ q in rotating reference frame are used as the indicators of the insulation failure fault.”
MethodLee, H., Jeong, H., Koo, G., Ban, J., & Kim, S. W. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2978690 · Cited by 151
“An interturn short-circuit fault (ISCF) is one of the most common stator winding faults [2].”
BackgroundWang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793188 · Cited by 150
“The turn fault current generates a second harmonic disturbance in the synchronous dq-axis reference frame [12].”
Haje Obeid, N., Battiston, A., Boileau, T., & Nahid-Mobarakeh, B. (2017) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2743419 · Cited by 98
“So far, the studies were restricted to an advanced fault case modeled by a permanent interturn short circuit [7]–[12].”
BackgroundMethodInfluentialSelf-citationComprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Ullah, Z., & Hur, J. (2018) · Energies · doi:10.3390/en11123309 · Cited by 77
“Therefore, this can be used as an indicator of ITSF by setting a threshold [81].”
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Robust Stator Winding Fault Detection in PMSMs With Respect to Current Controller Bandwidth
Huang, S., Aggarwal, A., Strangas, E. G., Li, K., Niu, F., & Huang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3030036 · Cited by 70
“Therefore, the ITSCs detection methods based on MCSA or MVSA, introduced in [5], [6], [12]–[14],”
BackgroundMethodFault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
Stator Interturn Fault Detection in Permanent-Magnet Machines Using PWM Ripple Current Measurement
Sen, B., & Wang, J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2515560 · Cited by 63
Qian, H., Guo, H. H., & Ding, X. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2439574 · Cited by 55
“Meanwhile, the phase voltage variation and torque ripple are usually considered as the fault characteristic quantities that reflect fault information [23], [24].”
BackgroundObeid, N. H., Boileau, T., & Nahid-Mobarakeh, B. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581760 · Cited by 52
“Most of the interturn fault models are the clean short circuit [13], [14] or the permanent low-value resistance [15] between two damaged turns [16], [17].”
BackgroundSelf-citationWei, D., Liu, K., Wang, J., Zhou, S., & Li, K. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3319157 · Cited by 54
“In [25], the second harmonic of the reference voltage in the dq frame is employed for more sensitive ITSC fault detection but the bandwidth is not mentioned.”
MethodHang, J., Hu, Q., Sun, W., Ren, X., Ding, S., Huang, Y., & Hua, W. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3167439 · Cited by 53
“In [24], the ITF diagnosis is realized through second harmonic component in the reference voltage vector.”
MethodAnalysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
Yuan, Q., Zafarani, M., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626264 · Cited by 51
“Since the inter-turn short-circuit fault increases the unbalance of the three-phase winding, the even harmonics in rotor reference frame can also be used as fault indicator [8]–[12].”
BackgroundLu, S., Qin, Y., Hang, J., Zhang, B., & Wang, Q. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2852978 · Cited by 45
“In this paper, synchronous demodulation technique [35], [36] is used to reconstruct a signal component using the extracted TFRid.”
MethodLai, C., Balamurali, A., Bousaba, V., Iyer, L. V., & Kar, N. C. (2014) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2014.6861775 · Cited by 42
Fault Detection of Permanent Magnet Synchronous Machines: An Overview
Li, H., Zhu, Z. Q., Azar, Z., Clark, R., & Wu, Z. (2025) · Energies · doi:10.3390/en18030534 · Cited by 42
“It is discovered that ITSC fault introduces 2 nd harmonics in dq -axis voltage and currents [34], which can be treated as an alternate 6 perspective of the same fault signatures with NSC [2].”
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., Takorabet, N., Meibody‐Tabar, F., & Clerc, G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387338 · Cited by 39
Self-citationKrzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33
“Moreover, the signals coming from the PMSM control-loop were used in the detection of inter-turn short circuits [21].”
BackgroundMethodvan der Geest, M., Polinder, H., Ferreira, J. A., Veltman, A., Wolmarans, J. J., & Tsiara, N. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2402641 · Cited by 33
Fault Detection and Condition Monitoring of PMSGs in Offshore Wind Turbines
Freire, N. M. A., & Cardoso, A. J. M. (2021) · Machines · doi:10.3390/machines9110260 · Cited by 39
“Synchronous demodulation is used to extract the magnitude of the second harmonic of the dq voltage references in [90], allowing interturn fault detection.”
MethodImproved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
Mechanism-Based Fault Diagnosis Deep Learning Method for Permanent Magnet Synchronous Motor
Li, L., Liao, S., Zou, B., & Liu, J. (2024) · Sensors · doi:10.3390/s24196349 · Cited by 33
Niu, F., Wei, F., Huang, S., Wu, L., Zhang, J., Huang, X., & Fang, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3273897 · Cited by 29
“In [12], ITSC fault is detected by extracting the magnitudes of the second harmonics in dq-axis voltages, and it is also detected by both the dc components and the second harmonics in dq-axis voltages in [13].”
BackgroundMethodInfluentialModeling and detection of the short-circuit fault in PMSM using Finite Element Analysis
Fitouri, M., Bensalem, Y., & Abdelkrim, M. N. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.07.769 · Cited by 29
Jiang, Y., Ji, B., Zhang, J., Yan, J., & Li, W. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15040165 · Cited by 30
“Harmonics at twice the angular velocity frequency of the DQ-axis voltage are utilized to detect ITSFs, as described in [74,75].”
MethodHang, J., Zhang, J., Ding, S., Huang, Y., & Wang, Q. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978139 · Cited by 25
“So far, many fault diagnosis methods are proposed for the PMSM, mainly focusing on short-circuit fault [7]–[10], static/dynamic eccentricity [13]–[15], partial/uniform demagnetization [16]–[19], and open-phase fault [20]–[22], while the research on the HRC is relatively few for the PMSM drive system.”
BackgroundXu, Y., Wang, Y., & Zou, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3125653 · Cited by 26
“Signal process methods use the time domain and the frequency domain characteristics of the sampled signals, such as actual currents [2]–[4], reference voltages [5]–[7], the zero-sequence voltage component (ZSVC) [18], [22], the zerosequence current component (ZSCC) [8], the air gap magnetic field [9], the stray magnet…”
MethodPietrzak, P., & Wolkiewicz, M. (2022) · Power Electronics and Drives · doi:10.2478/pead-2022-0009 · Cited by 29
Usman, A., Doiphode, N. T., & Rajpurohit, B. S. (2019) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2019.8883929 · Cited by 26
“Almost 40-50 % [10]-[14] of all electrical motor failures are subjected to mechanical faults.”
BackgroundLi, J., & Wu, C. (2017) · Applied Mathematics and Computation · doi:10.1016/j.amc.2017.05.071 · Cited by 22
Zhang, J., Zhan, W., & Ehsani, M. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3239426 · Cited by 22
“Fault detection is to determine whether the system has a fault [1], [2], [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], whereas fault severity estimation provides the degree of fault.”
BackgroundCurrent Vector Phase Based Weak Open-Circuit Fault Diagnosis of Voltage-Source Inverters
Zhang, Y., Liu, Y., Kang, S., & Wang, P. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3478766 · Cited by 22
“Theinverter plays an important role in the power conversion of PMSM, in which the open-circuit fault of the power switch is generally caused by a lack of signal and the breakage of switches [1], [2], [3], [4].”
Choi, S., Akin, B., Kwak, S., & Toliyat, H. A. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2302902 · Cited by 18
Quantitative Fault Severity Estimation for High-Resistance Connection in PMSM Drive System
Hang, J., Yan, D., Xia, M., Ding, S., & Wang, Q. (2019) · IEEE Access · doi:10.1109/access.2019.2901121 · Cited by 19
“As is known, many fault diagnosis methods are proposed for the PMSM drive system, mainly focusing on short-circuit fault [6]–[9], static/dynamic eccentricity [10]–[14], partial/ uniform demagnetization [15]–[18], and open phase fault [19]–[21], while the HRC is rarely researched for the PMSM.”
BackgroundDuan, R., Wu, L., Lyu, Z., Zhan, H., & Song, P. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3366595 · Cited by 18
Fault analysis of induction machine using finite element method (FEM)
Zaabi, W., Bensalem, Y., & Trabelsi, H. (2014) · International Conference on Sciences and Techniques of Automatic Control and Computer Engineering · doi:10.1109/sta.2014.7086711 · Cited by 18
Obeid, N. H., Boileau, T., & Nahid‐Mobarakeh, B. (2015) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2015.7356845 · Cited by 17
“Most of the model for inter-turn fault are the clean short circuit [12], [13] or a permanent law value resistance [14] between two defective turns [15], [16].”
BackgroundSelf-citationLaamari, Y., Allaoui, S., Abdelmalik, A., & Saad, S. (2021) · Mathematical Modelling and Engineering Problems · doi:10.18280/mmep.080220 · Cited by 18
“This method can distinguish the performance of failures and extract their features from stator current and vibration signals [6, 11].”
InfluentialHuang, S., Bi, Z., Sun, Z., Aggarwal, A., Huang, X., Wu, L., & Niu, F. (2022) · Energies · doi:10.3390/en15093248 · Cited by 14
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundOverview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Xiao, L., Li, S., Liu, C., & Zou, J. (2025) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2025.3528942 · Cited by 11
“Different methods, such as fast Fourier transform (FFT), Hilbert–Huang transform (HHT), and wavelet analysis, are employed to extract the current signature caused by ITSC fault to achieve the fault detection [7], [8].”
Suti, A., Rito, G. D., & Galatolo, R. (2022) · Aerospace · doi:10.3390/aerospace9080401 · Cited by 10
“Boileau [26] considered as a fault indicator the amplitude of the positive voltage sequence while Meinguet [27] used as an PMSM”
MethodYang, Y., Chen, Y., & Hao, W. (2020) · IET Electric Power Applications · doi:10.1049/elp2.12011 · Cited by 11
“Using an appropriate time‐ domain transformation, fault detection can be realised by analysing the magnitude of the second harmonic voltage [20].”
MethodGhods, M., Tabarniarami, Z., & Faiz, J. (2024) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2024.3369732 · Cited by 10
“There are more approaches for TTSC fault detection, which include the use of voltage signal [12], negative sequence current [13], high-frequency signal injection [14], and electromagnetic torque [15].”
MethodObeid, N. H., Boileau, T., & Nahid‐Mobarakeh, B. (2015) · HAL · Cited by 9
Self-citationA Novel Turn Fault Detection Strategy Based on High-Frequency Neutral-to-Ground Voltages
Wang, B., Feng, X., Zeng, J., & Wang, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3309939 · Cited by 9
“The second harmonic in the dq -axis, such as currents [9], [10], control voltages [11], active power, and reactive power [12], is commonly used for this purpose.”
BackgroundWei, D., Liu, K., Zhu, Z. Q., Zhou, S., Wang, J., & Chen, Y. (2024) · IET Electric Power Applications · doi:10.1049/elp2.12469 · Cited by 9
Palavicino, P. C., Lee, W., & Sarlioglu, B. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3203032 · Cited by 8
“[20], [21], and parameter estimation [22], [23].”
BackgroundGhods, M., Tabarniarami, Z., Faiz, J., & Bazrafshan, M. A. (2024) · IET Electric Power Applications · doi:10.1049/elp2.12452 · Cited by 7
Tabarniarami, Z., Ghods, M., Faiz, J., & Abedini, M. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3369970 · Cited by 9
The Propagation Mechanism of Fault Signatures in Squirrel Cage Induction Motor Drives
Maouche, Y., Oumaamar, M. E. K., Boucherma, M., Khezzar, A., & Razik, H. (2019) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-018-00037-1 · Cited by 7
“In order to avoid this problem many others [11, 12] give a demodulation method that allows the extraction of signatures fault of supply voltage approach without using signal processing.”
MethodLee, H., Jeong, H., Kim, S., & Kim, S. W. (2022) · Sensors · doi:10.3390/s22124639 · Cited by 7
“The ISCF is one of the most frequently occurring stator winding failures, and results in a short circuit owing to a breakdown of the insulation between adjacent windings [4].”
BackgroundCo-simulation of induction motor fed by PWM inverter under a broken bar fault
Zaabi, W., Bensalem, Y., & Trabelsi, H. (2015) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd.2015.7348155 · Cited by 4
Short-circuit faults in high-speed PM machines with parallel strands and coils
van der Geest, M., Polinder, H., & Ferreira, J. A. (2014) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp.2014.0467 · Cited by 4
Online control signal-based diagnosis of interturn short circuits of PMSM drive
Krzysztofiak, M., ZAWILAK, T., & Tarchała, G. (2023) · Archives of Electrical Engineering · doi:10.24425/aee.2023.143692 · Cited by 5
Investigation of Inter-Turn Short Circuit on a 9- Phase Permanent-Magnet Synchronous Machine
Hajj, A. E., Semail, E., Tounzi, A., Vizireanu, D., & Cheaytani, J. (2022) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem51905.2022.9910848 · Cited by 4
“The 3-phase PMSM with series-connected windings is by far the most studied machine [4]–[11].”
BackgroundA High-Order Extended Kalman Filter for Fault Detection In PMSM System
Chen, R., Yu, W., Wen, C., Zhang, Z., Li, H., & Zhang, X. (2022) · China Automation Congress (CAC) · doi:10.1109/cac57257.2022.10056079 · Cited by 3
“At present, the main fault detection methods of motor system are divided into three kinds: the method based on signal processing [5,6], the method based on data driving [7] and the approach based on analytical model.”
MethodStator Turn Fault Detection by Relative Voltage Residual Slopes With High-Frequency Injection
Feng, X., Wang, B., Wang, Z., Hua, W., Cheng, M., & Zhou, B. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3324307 · Cited by 4
“It should be noted that the above derivation is based on the assumption of one slot per pole and per phase for convenience [26], [27].”
BackgroundMeng, T., Lu, G., & Zhang, P. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3349578 · Cited by 3
“In consideration of that the magnetic flux generated by interturn fault current is opposite to the main flux, the second component will be the main harmonic [6], [7], [8], [9], [10], [11].”
BackgroundFault Analysis of Electrical Machine Drives Employing Novel Model Predictive Control
Akhare, Y. P., Ali, W. H., Fuller, J. H., & Attia, J. O. (2020) · International Journal of Advances in Scientific Research and Engineering · doi:10.31695/ijasre.2020.33909 · Cited by 2
“For this cause, some researchers have studied their proposed model using MATLAB /Simulink and validated experimentally to detect the effects of faults in an electrical machine [5-7].”
MethodDiagnosis of Short-circuits in Induction Motor Stator Winding Using a Modified Park Transformation
Tarchała, G., Wolkiewicz, M., & Krzysztofiak, M. (2020) · Power Electronics and Drives · doi:10.2478/pead-2020-0009 · Cited by 6
“Boileau et al. (2013) proposed a simple diagnostic method of stator windings for permanent magnet synchronous motor (PMSM) which may allow to automatically determine the amplitude of the second harmonic voltage signals without any requirement of using the spectral analysis.”
BackgroundMethodNishizawa, K., Li, M., Bai, J., & Sato, I. (2024) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems60997.2024.10921103 · Cited by 2
“The other methods in [6] and [7] detect the stator interturn fault by monitoring the instantaneous active power (IAP) and instantaneous reactive power (IRP).”
Yuan, Z., Wang, M., Bai, J., Liu, W., & Zheng, P. (2023) · AIP Advances · doi:10.1063/9.0000494 · Cited by 2
Duan, R., Wu, L., Lyu, Z., Zhan, H., & Hu, S. (2023) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc55163.2023.10238903 · Cited by 2
Fault-tolerant Control of wound rotor synchronous generator in wind turbines
Lešić, V., Vašak, M., Stojcic, G., & Wolbank, T. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960421 · Cited by 2
Hang, J., Ding, S., Li, H., & Wang, Q. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096574 · Cited by 2
“The previous literatures mainly focused on detection of the inter-turn fault [6]-[7], eccentricity fault [8]-[9], demagnetization fault [10]-[11] and open phase fault [12][13], in the PMSM drives, rarely covering the HRC.”
BackgroundIntegrated Design of a High Speed Magnetic Levitated Brushless Direct Current Motor System
Liu, G., & Liu, X. (2018) · Energies · doi:10.3390/en11051236 · Cited by 2
“Introduction With advances in active magnetic bearing (AMB) [1,2], electronic converters, new material, and control strategy, limitation of speed for rotating machines got a greatly improvment [3,4].”
BackgroundLi, D., Zhu, M., Zhao, Y., & Lin, S. (2024) · IEICE Electronics Express · doi:10.1587/elex.21.20240550 · Cited by 1
Bouzin, M., Postal, G., Dupont, A., & Gyselinck, J. J. C. (2025) · IEEE Student Conference on Electric Machines and Systems (SCEMS) · doi:10.1109/scems67400.2025.11267368 · Cited by 1
“This idea is based on the already existing papers which have proposed different harmonics-based fault indicators such as [8] or [9].”
Qu, W., & Wu, F. (2016) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2016.7831887 · Cited by 1
Li, D., Zhu, M., Zhao, Y., & Lin, S. (2025) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-025-02289-0 · Cited by 4
Vu, H., & Ma, T. T. H. (2021) · Advances in Science Technology and Engineering Systems Journal · doi:10.25046/aj0602107
“In [16] authors have shown the noticed feature of the inter-turn short-circuit fault is the magnitude of the second harmonic of the control voltages.”
BackgroundFault detection and fault tole rant control of interturn short circuit of double redundancy motor
Jin, T., Tian, W., & Zhao, W. (2023) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2522/1/012024
Comprehensive Component On-Board Diagnostics: Systematic Transformation Approach to Malfunctions
Rajan, R. S., Richert, F., & Pischinger, S. (2023) · SAE International Journal of Electrified Vehicles · doi:10.4271/14-12-03-0023
Servo Motor Electrical Fault Diagnosis of Misalignment Based on GRU Neural Network
Hu, D., Yang, M., Guo, Z., & Xu, D. (2023) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems59686.2023.10344501
“When the angle misalignment fault occurs, the transfer function relationship between the angular velocity of the drive shaft and the angular velocity of the motor shaft can be derived [6].”
BackgroundHigh-Frequency Signal Injection-Based Various Cable Connection Fault Diagnostics of PMSM
Li, Y., Xu, W., Wang, J., Jin, Z., & Fang, S. (2024) · Lecture notes in electrical engineering · doi:10.1007/978-981-97-1064-5_3
Online Stator Inter-Turn Short Circuit Faults Detection in Interior PMSM Drives
Bosson, S. P., Janouš, Š., Šmídl, V., Peroutka, Z., & Frank, Z. (2025) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2025.3601024 · Cited by 1
“In [5], [6], the second order harmonic of the current on the q axis is monitored for ITSC detection through harmonic analysis, where its amplitude is correlated with the severity of the fault, and detection is achieved by comparing the second order harmonic magnitude of the control voltage, derived…”
Research on asynchronous quadrature integral demodulation method for amplitude modulation signal
Ye, Y., & Wang, P. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae0c2b
Wang, Y., Li, S., Xu, Y., & Zou, J. (2025) · International Conference on System Reliability and Safety Engineering (SRSE) · doi:10.1109/srse67406.2025.11357423
Current Sensorless Control Strategies for an Automotive Electric Powertrain
Corne, A. (2019) · theses.fr (ABES) · doi:10.70675/21b311b1z73bdz4935z9495zde957adb16b0
Tang, H., Chai, Y., Dong, Z., Han, G., Cheng, H., & Li, W. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3687524
“P ERMANENT magnet synchronous motors (PMSMs) require fault diagnosis to ensure safe and reliable operation [1], [2].”
Electric Motor Emulator for Variable-frequency-driven Induction Motor with Stator Interturn Fault
Nishizawa, K., & Sato, I. (2026) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec-nagasaki2026-ec64663.2026.11597270
Enhanced Performance of Three‐Phase Induction Motor Based Inter‐Turn Faults Using Finite Element
Khalaf, M. A., Jumaa, F. A., Alazzawi, O. K. D., Najeeb, M., & Elrashidi, A. (2026) · Engineering Reports · doi:10.1002/eng2.70998
Metadata
- Authors
- Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F.
- Affiliations
- Groupe de Recherche en Énergie Électrique de Nancy (FR)
- Groupe de Recherche en Electronique et en Electrotechnique de Nancy, Université de Lorraine, 54518 Vandoeuvre Cedex, France
- ORCID
- Boileau, Thierry
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-12
- Volume
- 28
- Issue
- 12
- Pages
- 5647-5654
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2020495941
- Cited by
- 90
- References
- 32
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 14 · 2023: 11 · 2022: 9 · 2021: 4 · 2020: 8 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 7 · 2015: 7 · 2014: 5
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- permanent magnet synchronous motor, synchronous demodulation, second harmonic, dq frame, fault detection, threshold-based fault detection, low computational cost
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.