Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In this paper, a new technique for stator winding interturn fault detection in current-controlled permanent magnet synchronous machines is proposed. The method is based on online extraction of the second harmonic component of the voltage reference vector in the dq frame. It will be shown that the amplitude of this harmonic depends on the interturn fault severity and the fault detection is realized by comparing the magnitude of the control voltage second harmonic, derived using a proper time-domain transformation, to a predefined threshold. This is a low-cost method in CPU burden time. The experimental results show the validity of the proposed method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is shown that the ITSC introduces the 2 nd order harmonic signal into the d-q rotating reference frame (they correspond to the third-order harmonics in A-B-C frame; the classical Park transform reduces the order of the harmonic by one).”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“Thus, searching for some characteristic frequencies in the components of the reference voltage vector have been proposed in [52].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“Finally, filtered components create a vector whose amplitude becomes a fault indictor.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
In the citing paper
“The authors propose to transform the d-q frame voltage signals into a new frame rotating with three times the synchronous speed.In this frame the fault-related signals are constant in time and can be filtered by a low pass filter.Therefore, there is no need to apply the FFT on-line.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [52]
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 1×
“Well-known tools like fast Fourier transform and Wigner–Ville Distribution are applied for this purpose [18]–[20].”
MethodEL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373 · cited 2×
“So, they are well adapted for transportation applications either for propulsion or other equipments [2].”
BackgroundAdvances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140 · cited 2×
“It is well known that the stator winding faults are among the most spread failures in ac machines [9]–[11].”
BackgroundRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 1×
“An efficient way to improve the availability of a drive is to detect its faults in real time in order to switch to a degraded operating mode under fault conditions [5].”
BackgroundGrubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490 · cited 1×
“Because of the closeness of the spires belonging to the same phase, it is admitted that the first appearing faults are often turnto-turn [12]–[14].”
BackgroundModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282 · cited 1×
“This model is close to those presented in [29] and [30].”
MethodApplication of AI tools in fault diagnosis of electrical machines and drives-an overview
Awadallah, M. A., & Morcos, M. M. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.811739 · Cited by 220 · cited 1×
“Otherwise, the fault current grows up rapidly with the fault severity and may cause fire or lead to mechanical failures [26].”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214 · cited 1×
“Well-known tools like fast Fourier transform and Wigner–Ville Distribution are applied for this purpose [18]–[20].”
MethodEbrahimi, B. M., & Faiz, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050496 · Cited by 208
Control Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2198077 · Cited by 164 · cited 1×
“To monitor critical devices in real time, existing methods consist in either adding sensors [6], [7] or injecting appropriate signals [8].”
MethodCheng, S., Zhang, P., & Habetler, T. G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064276 · Cited by 149 · cited 1×
“Other approaches based on estimation of direct and inverse impedances are proposed [21].”
BackgroundOperation of fault tolerant machines with winding failures
Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.815095 · Cited by 148
Dynamic Modeling and Control for SPMSMs With Internal Turn Short Fault
Jeong, I., Hyon, B. J., & Nam, K. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222049 · Cited by 128 · cited 1×
“This model is close to those presented in [29] and [30].”
MethodAlternatives for assessing the electrical integrity of induction motors
Kohler, J. L., Sottile, J., & Trutt, F. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.158836 · Cited by 108 · cited 1×
“In [22], the authors propose to use the RMS value of the inverse stator current as a fault indicator.”
MethodNeti, P., & Nandi, S. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018905 · Cited by 103 · cited 1×
“To monitor critical devices in real time, existing methods consist in either adding sensors [6], [7] or injecting appropriate signals [8].”
MethodBriz, F., Degner, M. W., Garcia, P., & Diez, A. B. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.926773 · Cited by 94 · cited 1×
“To monitor critical devices in real time, existing methods consist in either adding sensors [6], [7] or injecting appropriate signals [8].”
MethodReal-Time Detection of Interturn Faults in PM Drives Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid-Mobarakeh, B., Clerc, G., & Meibody-Tabar, F. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168929 · Cited by 92 · cited 2×
“With electrification of transportation vehicles, this problem is currently studied in aeronautical industry where fault detection is considered as one of the most important advantage of electric actuators compared to hydraulic ones [17].”
BackgroundSelf-citationDetection of stator short circuits in VSI-fed brushless DC motors using wavelet transform
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847964 · Cited by 87
Detection of Stator Faults in Induction Machines Using Residual Saturation Harmonics
Nandi, S. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.880838 · Cited by 83 · cited 1×
“It is well known that the stator winding faults are among the most spread failures in ac machines [9]–[11].”
BackgroundAn Advanced Stator Winding Insulation Quality Assessment Technique for Inverter-Fed Machines
Yang, J., Cho, J., Lee, S. B., Yoo, J.-Y., & Kim, H.-D. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.916753 · Cited by 65 · cited 1×
“In this type of applications, the state of health of devices can be tested offline [3], [4].”
BackgroundA New Strategy for Condition Monitoring of Adjustable Speed Induction Machine Drive Systems
Lee, S. B., Yang, J., Hong, J., Yoo, J.-Y., Kim, B., Lee, K., Yun, J., Kim, M., Lee, K., Wiedenbrug, E. J., et al. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2062200 · Cited by 61
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60 · cited 1×
“So, the fault indicator has to be compared to a prerecorded threshold corresponding to its value for the healthy machine [31], [32].”
BackgroundExperimentally Validated Dynamic Fault Model for PMSM with Stator Winding Inter-Turn Fault
Vaseghi, B., Nahid-Mobarakeh, B., Takorabet, N., & Meibody-Tabar, F. (2008) · 2008 IEEE Industry Applications Society Annual Meeting · doi:10.1109/08ias.2008.24 · Cited by 57 · cited 3×
“For more details, interested readers are invited to see [28].”
BackgroundMethodSelf-citationCoupling Pattern Recognition With State Estimation Using Kalman Filter for Fault Diagnosis
Ondel, O., Boutleux, E., Blanco, É., & Clerc, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2181133 · Cited by 55 · cited 1×
“In [27], the authors present a global fault diagnosis tool including different fault indicators and a decision maker based on pattern recognition.”
BackgroundA survey of methods for detection of stator related faults in induction machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2003) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2003.1234544 · Cited by 48 · cited 1×
“Other authors present methods based on axial flux measurement requiring additional sensors [23], [24].”
Method(2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544200 · Cited by 44 · cited 1×
“P ERMANENT magnet synchronous machines (PMSM) have one of the best torque/mass ratios among the electric drives [1], [2].”
BackgroundStudy of an induction motor working under stator winding inter-turn short circuit condition
Melero, M. G., Cabanas, M. F., Rojas, C. H., Orcajo, G. A., Cano, J. M., & Solares, J. (2003) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2003.1234546 · Cited by 37 · cited 1×
“Other authors present methods based on axial flux measurement requiring additional sensors [23], [24].”
MethodBack-EMF Based Detection of Stator Winding Inter-turn Fault for PM Synchronous Motor Drives
Boileau, T., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544105 · Cited by 35
Self-citationOndel, O., Clerc, G., Boutleux, E., & Blanco, É. (2008) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.921559 · Cited by 33 · cited 1×
“Finally, expert systems are widely used to detect different faults in electrical drives [25].”
BackgroundImpact of the aeronautic environment on the Partial Discharges Ignition: A basic study
Koliatene, F., Lebey, T., Cambronne, J.-P., & Dinculescu, S. (2008) · IEEE International Symposium on Electrical Insulation · doi:10.1109/elinsl.2008.4570404 · Cited by 30 · cited 1×
“Indeed, partial discharges in stator windings increase significantly because of high dv/dt imposed by power electronic devices supplying ac machines [16].”
BackgroundBellomo, J. P., Lebey, T., Oraison, J. M., & Peltier, F. (2002) · International Conference on Properties and Applications of Dielectric Materials (ICPADM) · doi:10.1109/icpadm.1994.414130 · Cited by 16 · cited 1×
“Indeed, the problem of health monitoring of variable speed electric drives raised in the 1990s when conventional industry found a decrease in the lifetime of the ac machines due to insulation problem [15].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
“It is well known that the stator winding faults are the most prevalent failures in ac machine, where the interturn fault is one of the most common stator winding faults [6].”
BackgroundZafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“In [91], the second harmonics in the reference d–q voltage v∗ d and v∗ q in rotating reference frame are used as the indicators of the insulation failure fault.”
MethodLee, H., Jeong, H., Koo, G., Ban, J., & Kim, S. W. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2978690 · Cited by 151
“An interturn short-circuit fault (ISCF) is one of the most common stator winding faults [2].”
BackgroundWang, B., Wang, J., Griffo, A., & Sen, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2793188 · Cited by 150
“The turn fault current generates a second harmonic disturbance in the synchronous dq-axis reference frame [12].”
Metadata
- Authors
- Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F.
- Affiliations
- Groupe de Recherche en Énergie Électrique de Nancy (FR)
- Groupe de Recherche en Electronique et en Electrotechnique de Nancy, Université de Lorraine, 54518 Vandoeuvre Cedex, France
- ORCID
- Boileau, Thierry
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2013-12
- Volume
- 28
- Issue
- 12
- Pages
- 5647-5654
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2020495941
- Cited by
- 90
- References
- 32
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 14 · 2023: 11 · 2022: 9 · 2021: 4 · 2020: 8 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 7 · 2015: 7 · 2014: 5
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- permanent magnet synchronous motor, synchronous demodulation, second harmonic, dq frame, fault detection, threshold-based fault detection, low computational cost
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.