In order to increase the reliability and availability of wind turbines, condition monitoring and fault diagnosis are considered crucial means to achieve these goals. In this context, direct drives wind turbines based on permanent-magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. However, several statistical studies point out that power converters are a significant contributor to the overall failure rate of modern wind turbines. Accordingly, this paper presents a new algorithm for multiple open-circuit faults diagnosis in full-scale back-to-back converters, applied in PMSG drives used for wind turbine systems. The proposed method is based on a Luenberger observer and on an adaptive threshold, which can guarantee a reliable diagnosis independently of the drive operating conditions. Several simulation and experimental results using a PMSG drive with a full-scale converter are presented, showing the diagnostic algorithm effectiveness and robustness against false alarms for both generator- and grid-side converters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [269]
Citations
Cites
Luenberger, D. (1971) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1971.1099826 · Cited by 2,709 · cited 1×
“The Luenberger state observer [38] has been widely used for the control of PMSM drives [39], [40] and for three phase”
MethodAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860 · cited 1×
“A comparative study between different powers switches technologies used in wind energy conversion systems, and types of faults that can occur in these semiconductors is also presented in [5].”
BackgroundAgeing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“Fast detection times can be achieved using voltage-based techniques at the cost of additional voltage sensors [9]–[11].”
BackgroundFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“A diagnostic method based on sliding mode observer for open-circuit faults in modular multilevel converters was proposed in [25].”
MethodFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 1×
“The current space vector trajectory diameter can also be used for the localization of inverter power switch open-circuit faults [7], [8].”
BackgroundOpen-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300 · cited 1×
“These problems were mitigated by the normalization of the diagnostic variables, as proposed in [21].”
MethodA New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Estima, J. O., & Marques Cardoso, A. J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168800 · Cited by 298 · cited 1×
“Recent advances in power converters fault diagnosis by the Park’s Vector Approach were also proposed in [31]–[33].”
BackgroundSelf-citationOpen-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
Freire, N. M. A., Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2207655 · Cited by 277 · cited 1×
“Recent advances in power converters fault diagnosis by the Park’s Vector Approach were also proposed in [31]–[33].”
BackgroundSelf-citationJung, S.-M., Park, J.-S., Kim, H.-W., Cho, K.-Y., & Youn, M.-J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212916 · Cited by 271
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264 · cited 1×
“A new approach with a detection time lower than 10 μs was presented in [27].”
MethodAn, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262 · cited 1×
“Fast detection times can be achieved using voltage-based techniques at the cost of additional voltage sensors [9]–[11].”
BackgroundFPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems
Karimi, S., Gaillard, A., Poure, P., & Saadate, S. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005244 · Cited by 245
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241 · cited 1×
“An open-circuit fault diagnosis technique for a gridconnected neutral point clamped inverter was presented in [35], where the diagnosis is accomplished without using additional sensors or electrical devices.”
MethodA state observer for the permanent-magnet synchronous motor
Jones, L. A., & Lang, J. H. (1989) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.31500 · Cited by 231
Campos-Delgado, D. U., & Espinoza-Trejo, D. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2047829 · Cited by 224 · cited 1×
“Observer-based approaches for single and simultaneous faults were addressed in [23], [24].”
BackgroundMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 1×
“The use of currents average values calculation was successfully applied to the Park’s Vector approach [20], presenting however problems regarding the tuning effort, load dependency, and generation of false alarm issues.”
MethodRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194 · cited 1×
“Other comparative studies and surveys can also be found in the literature regarding fault diagnostic methods for inverter single power switch open-circuit faults [17]–[19].”
BackgroundFreire, N. M. A., Estima, J. O., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279383 · Cited by 167 · cited 1×
“A more recent approach proposes the use of a voltage observer, avoiding the use of extra sensors [12].”
BackgroundSelf-citationPerformance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers
Rothenhagen, K., & Fuchs, F. W. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1354769 · Cited by 141 · cited 1×
“A comparative study of fault diagnostic techniques applied to active rectifiers was addressed in [16], where some methods were evaluated according to various parameters.”
MethodAC voltage and current sensorless control of three-phase PWM rectifiers
Lee, D., & Lim, D.-S. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805592 · Cited by 134
FPGA-Based Reconfigurable Control for Fault-Tolerant Back-to-Back Converter Without Redundancy
Shahbazi, M., Poure, P., Saadate, S., & Zolghadri, M. R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2200214 · Cited by 125 · cited 1×
“Fast fault detection and reconfiguration using a FPGA applied to a back-to-back converter was proposed in [13], [14] allowing the drive continuous operation.”
MethodRecent advances in fault diagnosis by Park's vector approach
Estima, J. O., Freire, N. M. A., & Cardoso, A. J. M. (2013) · 2013 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD) · doi:10.1109/wemdcd.2013.6525187 · Cited by 120
Self-citationDiagnosis and Fault-Tolerant Control of Three-Phase AC–DC PWM Converter Systems
Im, W.-S., Kim, J.-M., Lee, D., & Lee, K. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2255111 · Cited by 104 · cited 1×
“A similar approach also based on the currents Park’s Vector phase was also proposed in [34], applied to a pulse width modulation (PWM) rectifier.”
MethodVoltage source inverter fault diagnosis in variable speed AC drives, by Park's vector approach
Mendes, A. M. S. (1998) · Seventh International Conference on Power Electronics and Variable Speed Drives · doi:10.1049/cp:19980607 · Cited by 102
Trabelsi, M., Boussak, M., & Gossa, M. (2010) · The XIX International Conference on Electrical Machines - ICEM 2010 · doi:10.1109/icelmach.2010.5608044 · Cited by 94 · cited 1×
“The current space vector trajectory diameter can also be used for the localization of inverter power switch open-circuit faults [7], [8].”
BackgroundFault-Tolerant Matrix Converter Motor Drives With Fault Detection of Open Switch Faults
Khwan-on, S., Lillo, L. D., Empringham, L., & Wheeler, P. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162711 · Cited by 94 · cited 1×
“Fault diagnostic methods and fault-tolerant strategies applied to matrix converters are also gaining more and more interest by the scientific community [36], [37].”
BackgroundFPGA-Based Fast Detection With Reduced Sensor Count for a Fault-Tolerant Three-Phase Converter
Shahbazi, M., Poure, P., Saadate, S., & Zolghadri, M. R. (2012) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2209665 · Cited by 83 · cited 1×
“In [15], the same approach is applied to a threevoltage-source inverter.”
MethodFault diagnosis scheme for open‐circuit faults in field‐oriented control induction motor drives
Espinoza‐Trejo, D. R., Campos‐Delgado, D. U., Bossio, G., Bárcenas, E., Hernández‐Díez, J. E., & Lugo‐Cordero, L. F. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2012.0256 · Cited by 78 · cited 1×
“Observer-based approaches for single and simultaneous faults were addressed in [23], [24].”
BackgroundWavelet-based switching faults detection in direct torque control induction motor drives
Aktas, M., & Turkmenoglu, V. (2010) · IET Science, Measurement & Technology · doi:10.1049/iet-smt.2009.0121 · Cited by 77 · cited 1×
“The analysis of the second-order harmonic component in the q-axis or the discrete wavelet transform can also be effectively used for voltage source inverter open-circuit faults diagnosis [29], [30].”
MethodPotamianos, P. G., Mitronikas, E. D., & Safacas, A. N. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2240639 · Cited by 74 · cited 1×
“Fault diagnostic methods and fault-tolerant strategies applied to matrix converters are also gaining more and more interest by the scientific community [36], [37].”
BackgroundKim, K.-H., Gu, B.-G., & Jung, I.-S. (2011) · IET Electric Power Applications · doi:10.1049/iet-epa.2010.0272 · Cited by 45 · cited 1×
“The analysis of the second-order harmonic component in the q-axis or the discrete wavelet transform can also be effectively used for voltage source inverter open-circuit faults diagnosis [29], [30].”
MethodSethom, H. B. A., & Ghedamsi, M. A. (2008) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 37
Estima, J. O., & Cardoso, A. J. M. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342310 · Cited by 33 · cited 1×
“The use of average values calculations was also used in [22], applied to reference currents errors and allowing to achieve fast detection and multiple open-circuit faults diagnosis.”
MethodSelf-citationLow-cost diagnostic method for open-switch faults in inverters
An, Q. T., Sun, L. Z., Sun, L., & Jahns, T. M. (2010) · Electronics Letters · doi:10.1049/el.2010.0611 · Cited by 30
Hardware‐circuit‐based diagnosis method for open‐switch faults in inverters
An, Q., Sun, L. Z., & Sun, L. Z. (2013) · Electronics Letters · doi:10.1049/el.2013.0641 · Cited by 20 · cited 1×
“A different hardware approach was also successfully demonstrated in [28].”
MethodHafez, B., Abdel-Khalik, A. S., Massoud, A. M., Ahmed, S., & Lorenz, R. D. (2012) · Qatar University QSpace (Qatar University) · Cited by 4
Research works printed but not linked: 1
- 10.1109/iemdc.1999.769220 · DOI · Paper page
Cited by
Li, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
“Detection methods for IGBT open-circuit faults have been extensively studied in literature works [27]–[31], but they are customized for traditional two-level voltage source inverters.”
MethodFault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
BackgroundAn Overview on Fault Diagnosis, Prognosis and Resilient Control for Wind Turbine Systems
Gao, Z., & Liu, X. (2021) · Processes · doi:10.3390/pr9020300 · Cited by 281
“In [34], a fault diagnosis method was presented for multiple open-circuit faults in back-to-back converters of a permanent magnet synchronous generator (PMSG) drive for wind turbine systems where a Luenberger observer and adaptive threshold were used to ensure a reliable diagnosis independent of drive operation condit…”
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“shows that they may be classified as current signatures [12]– [20], [22]–[25], [30], [33]–[36] and voltage signatures based methods [26]–[29], [31], [32].”
BackgroundMethodSelf-citationGou, B., Ge, X., Wang, S., Feng, X., Kuo, J. B., & Habetler, T. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465299 · Cited by 191
“Model-based approaches such as the parity space method or observer-based methods have been widely used to detect the faults of power drive systems [8]–[10].”
Method
Metadata
- Authors
- Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J.
- Affiliations
- University of Beira Interior (PT)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-05
- Volume
- 30
- Issue
- 5
- Pages
- 2689-2702
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2067610416
- Cited by
- 212
- References
- 43
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 15 · 2023: 21 · 2022: 18 · 2021: 17 · 2020: 21 · 2019: 28 · 2018: 20 · 2017: 20 · 2016: 24 · 2015: 12
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Portuguese Foundation for Science and Technology (SFRH/BPD/87135/2012)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- open-circuit fault diagnosis, back-to-back converter, permanent magnet synchronous generator, direct-drive wind turbine, Luenberger observer, adaptive threshold, condition monitoring, generator-side converter, grid-side converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.